Flood
INVLSR (3)
LSRLEN (2)
FSPF
BADSRC (3)
A-2
Installation and Troubleshooting Guide
To display error messages by way of Telnet:
1.
From the prompt, type errShow.
2.
To scroll through the error list, type
3.
Scroll through the error log (if no errors were encountered, the message
appears).
Table A-1 shows the error messages organized by module.
"  
An unknown Link State Record
has been received from a neigh-
bor switch.
The local switch is trying to cre-
ate a Link State Update that
exceeds the maximum length.
The neighbor switch domain ID
has changed, without the link
going down.
)  
Check that all paths and routing tables are
correct using the commands uPathShow
<domain>, or uPathAllShow.
If the paths are not correct reboot the
neighbor switch that sent the wrong data.
Check the paths and routes again. If they
are still incorrect, reboot the local switch.
Check that all paths and routing tables are
correct. If they are not, reboot the local
switch.
The system automatically recovers.