DIAG-BUS_TIMEOUT
[portRegTest, sramRetention-
Test]
DIAG-CAMINIT
[camTest]
DIAG-CAMSID
[camTest]
DIAG-CLEAR_ERR
DIAG-SMBISRF
[centralMemoryTest]
DIAG-CMBISRTO
[centralMemoryTest]
DIAG-CMERRPTN
[centralMemoryTest]
DIAG-CMERRTYPE
[centralMemoryTest]
DIAG-CMICKSUM
[cmiTest]
DIAG-CMIDATA
[cmiTest]
DIAG-CMIINVCAP
[cmiTest]
support.dell.com

   
ASIC register or ASIC SRAM
did not respond to an ASIC
data access
Port failed to initialize due to
one of the following reasons:
Switch not disabled
Diagnostic queue absent
Malloc failed
Chip is not present
Port is not in loopback
mode
Port is not active
ASIC failed SID NO translation
test
Port's diag error flag (OK or
BAD) is cleared
ASIC's Central Memory
SRAMS did not complete the
BISR within the timeout period
ASIC's Central Memory
SRAMS did not complete the
BISR within the timeout period
Error detected at the wrong
port
Port got the wrong CMEM
error type
CMI message received failed
bad checksum test
CMI data received did not
match date transmitted
Unintended ASIC erroneously
got CMI capture flag
&
)  
ASIC failure
Replace main-
board assembly
Software opera-
Retry, reboot or
tional setup error
replace main-
or mainboard
board assembly
failure
ASIC failure
Replace main-
board assembly
Informational only
None required
ASIC failure
Replace main-
board assembly
ASIC failure
Replace main-
board assembly
ASIC failure
Replace main-
board assembly
ASIC failure
Replace main-
board assembly
ASIC or mainboard
Replace main-
failure
board assembly
ASIC or mainboard
Replace main-
failure
board assembly
ASIC or mainboard
Replace main-
failure
board assembly