Dell PowerVault 50F Installation And Troubleshooting Manual page 146

Dell powervault 56f 16-port fibre channel switch installation and troubleshooting guide
Hide thumbs Also See for PowerVault 50F:
Table of Contents

Advertisement

A-10 Installation and Troubleshooting Guide
The possible security level values are:
1 — Critical
2 — Error
3 — Warning
4 — Informational
5 — Debug
NOTE: If the same error occurs within the same module (for example, the DIAG-
REGERR_UNRST module) but on different ports, the number of occurrences for that
message is incremented in brackets (up to 999), and the error number is not incre-
mented (that is, though it may occur 999 times, it occupies one message in the 320
message buffer).
To display error messages from the front panel:
1.
From the front panel, click the Status menu.
2.
From the Status window, click Error Log.
3.
Scroll through the error log. If no errors occur, the panel displays
If any port fails during a diagnostic test, it is marked
To retest a port which has been marked
diagClearError port# command. This command clears the port status only and does
not clear the logs or change the port's condition.
Some messages contain the following abbreviations:
sb — Should Be
er — Bits in error
NOTE: If you run the portStatsShow or the diagShow command prior to running a
test, errors may appear as a result of the normal synchronization process. These
errors should be addressed if the number of errors found increases when running the
portStatsShow command again
Table A-7 describes possible failure actions.
% $
ramTest
portRegTest
centralMemoryTest
cmlTest
, clear the port and set to
)  
Replace mainboard assembly
Replace mainboard assembly
Replace mainboard assembly
Replace mainboard assembly
.
in the status display.
using the