Dell PowerVault 50F Installation And Troubleshooting Manual page 152

Dell powervault 56f 16-port fibre channel switch installation and troubleshooting guide
Hide thumbs Also See for PowerVault 50F:
Table of Contents

Advertisement


DIAG-CMINOCAP
[cmiTest]
DIAG-CMISA1
[cmiTest]
DIAG-CMNOBUF
[centralMemoryTest]
DIAG-DATA
[portLoopbackTest, crossPort-
Test]
DIAG-ERRSTAT
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-INIT
[portLoopbackTest, crossPort-
Test, spinSilk]
DIAG-INTNIL
[cmlTest]
A-16 Installation and Troubleshooting Guide

   
CMI intended receiver ASIC
failed to get CMI capture flag
An attempt to send a CMI mes-
sage from ASIC to ASIC failed
Port could not get any buffer
Payload received by port did
not match payload transmitted
Port Error Statistics counter is
nonzero, meaning an error was
detected when receiving
frames.
One of the following status
errors occurred:
Enc_In: Encoding error,
inside frame
CRC_err: Cyclic redun-
dancy check on frame
failed
TruncFrm: Truncated
frame
FrmTooLong: Frame too
long
BadEOF: Bad end of file.
Enc_out: Encoding error,
outside frame
BadOrdSet: Bad symbol
on fiber-optic cable
DiscC3: Discarded Class 3
frames
Port failed to go active in the
loopback mode requested
ASIC failed to get a CMI error
(interrupt)
&
)  
ASIC or mainboard
Replace main-
failure
board assembly
ASIC failure
Replace main-
board assembly
ASIC failure
Replace main-
board assembly
Mainboard, GBIC
Replace main-
module or fiber
board assembly,
cable failure
GBIC module or
fiber cable
ASIC, mainboard,
Replace main-
GBIC module or
board assembly,
fiber cable failure
GBIC module or
fiber cable
ASIC, mainboard,
Replace main-
GBIC module or
board assembly,
fiber cable failure
GBIC module or
fiber cable
ASIC failure
Replace main-
board assembly

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault 51fPowervault 56f

Table of Contents