Dell DR4000 Administrator's Manual page 104

Administrator guide
Hide thumbs Also See for DR4000:
Table of Contents

Advertisement

FILE LOCATION: C:\Users\bruce_wylie\Desktop\Dell
Docs\~Sidewinder_Docs_DR4000\FRAME_Conversion_DR4000_AdminGuide\~DR4000_AG_F
Table 8-1. DR4000 System Alert and Event Messages
Type/Number
Alert/Event Message
2170692
Solid-state drive (SSD) is
disconnected from the NVRAM.
2170693
NVRAM capacitor is not charging. Contact Dell Support for
2170694
NVRAM failed to backup or
restore data during the last reboot.
2170695
NVRAM is not yet ready to accept
write commands.
2170696
NVRAM hardware has failed.
2170697
File server is failing repeatedly.
DR4000 system is entering
Maintenance mode so it can run
the filesystem scan utility.
2170698
DR4000 system is not initialized. Contact Dell Support for
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 1 / 1 0 / 1 2 - F O R P R O O F O N LY
96
Troubleshooting and Maintenance
Description/Meaning or Action
Contact Dell Support for
support assistance or
intervention.
If problem persists after reboot,
replace the NVRAM.
support assistance or
intervention.
If problem persists after five
minutes of power shutdown,
replace the NVRAM.
Contact Dell Support for
support assistance or
intervention.
Contact Dell Support for
support assistance or
intervention.
Wait until the NVRAM is ready.
Contact Dell Support for
support assistance or
intervention.
Contact Dell Support for
support assistance or
intervention.
For more information, see
"About the DR4000
Maintenance Mode" on
page 114.
support assistance or
intervention.
For more information, see
"Initializing the DR4000
System" on page 13.

Advertisement