Other SCSI-2
Devices
CAUTION!
SCSI Chain Limits
2-4 Installing Your Tower
As an alternative to the HP 7-bay tower described above, you
can attach a chain of up to four SCSI-2 stand-alone (external)
drives to the HP J3278A server/tower, using its rear SCSI-2
connector. The connector is 50-pin female high-density micro-D.
No more than four (4) SCSI devices chained from the server
tower.
Cable lengths between devices limited to one (1) meter.
Total external cabling limited to four (4) meters.
Industry-standard SCSI-2 cables and terminators are available
in different lengths and with different connector types; obtain
cables that match the connectors on your drives. The HP SCSI
products in the table below may, or may not, match your drives.
HP Product Meters Type of SCSI Connectors
C2955A
0.5
C2908A
1.0
K2286
1.0
K2296
1.0
92222A
0.5
92222B
1.00
K2291
C2904A
The server tower will manage the second SCSI bus composed of
the added drives; you must set the SCSI IDs of your drives for
that bus, and terminate the chain.
50-pin high-density (thumb screws), male/male
50-pin low-density (bail lock) to high-density (latch
clip), male/male
50-pin low-density (bail lock) to high-density (thumb
screws), male/male
50-pin low-density (bail lock), male/male
(For drive-to-drive connections only)
Active Terminator, 50-pin low-density, (bail lock)
Active Terminator, 50-pin high-density, (thumb
screws)
Need help?
Do you have a question about the J3278B - SureStore CD-ROM Server/Tower 7 NAS Server and is the answer not in the manual?