This section contains the procedures referenced from the earlier
sections on the front-panel indicators "Error Conditions" on page
9-4 and the "Problem" section starting on page 9-5.
The diagnostic test will test the server module's memory and the
operation of the connected drives.
Before using the diagnostic test, please note:
Users currently accessing the server/tower will be inter-
rupted.
The diagnostic test is only available for the first hour after
you power on or restart the server/tower. You must restart
the server/tower before you can repeat the diagnostic test.
To test the data-transfer operation of a CD-ROM drive, the
drive must have a CD inserted with a file larger than
10 Mbytes on it.
Conduct the diagnostic test as follows:
1. If using a web browser, start the browser and enter the URL
of the server's diagnostic page:
http://<IP address>/config/html/diag.htm
Example Diagnostic Result