301 RECOVERY ROM
AUTOFLASH DONE
302 RECOVERY ROM
AUTOFLASH FAILED
303 ROM CLONING
STARTED
304 ROM CLONING
DONE
305 ROM CLONING
FAILED
52
LCD panel and message descriptions
Type
Description
Informational
The array controller has
successfully completed the
process of copying the
current active firmware
image into the backup
recovery ROM.
Error
The array controller failed
to copy the current active
firmware image into the
backup recovery ROM.
Recovery ROM support is
disabled.
Informational
In dual-controller MSA
only, this indicates that
the firmware from one of
the controllers is being
copied onto the other array
controller. Both controllers
must be running the same
version of firmware in order
for controller redundancy to
operate.
If both array controllers are
in the power-up sequence,
then the most recent version
of firmware will be used.
If one array controller has
already completed the
power-up sequence and is
active, then its version of
firmware will be used even
if less recent.
Informational
In dual-controller MSA only,
this indicates that the two
array controllers in an MSA
have finished copying one
array controller's version of
firmware to the other array
controller. Both controllers
must be running the same
version of firmware in order
for controller redundancy to
operate.
Error
In dual-controller MSA
only, this indicates that the
two array controllers in an
MSA failed to copy one
array controller's version of
firmware to the other array
controller. Both controllers
must be running the same
version of firmware in order
for controller redundancy to
operate.
Action
Remove the failing array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
The ROM autoflash process
is attempted again.
Should the issue persist,
contact HP support.
Remove the standby array
controller, wait 10 seconds,
and then reinsert the array
controller ensuring that it is
fully seated in the chassis.
The ROM cloning process is
attempted again.
Should the issue persist,
contact HP support.