4 Available diagnostic tools

The following is a partial list of the tools that are supported for use with the MSA:
• Array Configuration Utility (ACU) overview
• Array Configuration Utility - Command Line Interface overview
• MSA Command Line Interface (MSA-CLI) overivew
• Array Diagnostics Utility (ADU) overview
• HP Systems Insight Manager (HP-SIM) overview
• HP Storage Management Initiative Specification (SMIS) overview
• System Event Analyzer (SEA) overview
Array Configuration Utility (ACU) overview
The Array Configuration Utility (ACU) is a browser-based tool used to configure an array controller and
its storage. The ACU
The ACU is supported for use in Windows, Linux, and NetWare environments and can run locally
through a browser, remotely through HP Systems Insight Manager (HP-SIM), or offline from the MSA
Support Software CD.
The ACU:
Runs online in Windows and Linux environments.
Runs offline (from a bootable CD) in other ProLiant server environments such as NetWare.
Provides a graphical view of HP drive array configurations.
Includes easy-to-use configuration Wizards.
Provides different operating modes, enabling faster configuration or greater control over the
configuration options.
Suggests the optimum configuration for unconfigured systems.
Displays on-screen tips for individual steps of a configuration procedure.
Allows the setting of access privileges to specific storage LUNs to be limited to specific hosts.
Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
NOTE:
For optimum performance, the minimum display settings are 800 × 600 resolution and 256 colors.
Servers running Microsoft operating systems require Internet Explorer 5.5 (with Service Pack 1) or later.
For Linux servers, see the README.TXT file for additional browser and support information.
For Web or network access, a combination of the following may need to be installed and properly
configured:
Windows Internet Explorer
TCP/IP and SNMP services
Agents such as HP-SIM
Host Bus Adapter drivers
For more information about the ACU, see the following:
ACU section of the array configuration reference guide, available on the Documentation CD or the
Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000.
maintenance and service guide
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

353803-b22 - storageworks modular smart array 1000 san starterStorageworks 1000 - modular smart arrayStorageworks 1000

Table of Contents