Message
106 VOLUME #<n>
STATE WAITING TO
REBUILD
107 VOLUME #<n>
STATE WAITING TO
EXPAND
108 VOLUME #<n>
STATE MISSING
DRIVES
109 VOLUME #<n>
STATE WRONG DRIVE
REPLACED
110 VOLUME #<n>
EXPANSION DISABLED
111 VOLUME #<n>
INITIALIZING PARITY
48
LCD panel and message descriptions
Type
Description
Informational
The configured volume is
waiting to start rebuilding
data on a SCSI hard drive
that replaces a previously
failed drive. The rebuild
may not have started yet
because the array controller
is already performing
a rebuild on another
configured volume.
Informational
The configured volume is
waiting to start a volume
expansion operation.
The expansion may have
not started yet because
another configured volume
is undergoing expansion or
a rebuild is occurring on
the configured volume.
Error
The configured volume is
missing too many of the
SCSI hard drives that it is
composed of, making it
unusable. The volume is
disabled.
Error
The configured volume
appears to have had
known, good SCSI hard
drives replaced instead of
known, failed hard drives.
Informational
The volume expansion
operation on the configured
volume has been disabled.
This may be because
a rebuild operation
is ongoing, another
expansion is already
running, or the cache
memory is disabled due
to a low battery. The
expansion will start once
the condition has been
cleared.
Informational
The array controller is
calculating and storing
parity information for the
configured volume and
therefore performance may
be lower until it completes.
Action
Power off the MSA and
then all attached storage
enclosures. Unplug and
reinsert all SCSI hard drives
ensuring they are fully seated
in their bays. Check the
cables connecting the MSA
to any attached storage
enclosures. Power on the
attached enclosures and
then the MSA.
The MSA should be powered
off and the good hard drives
should be restored while the
failed hard drives should be
replaced.

Advertisement