HP 201723-B21 - StorageWorks Modular SAN Array 1000 Hard Drive Maintenance And Service Manual page 54

Modular smart array
Hide thumbs Also See for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive:
Table of Contents

Advertisement

Message
402 STORAGE BOX
#<n> FAN DEGRADED
403 STORAGE BOX
#<n> FAN HOT
INSERTED
404 STORAGE BOX
#<n> FAN HOT
REMOVED
405 STORAGE BOX
#<n> TEMPERATURE OK
406 STORAGE BOX
#<n> OVERHEATING
407 STORAGE BOX
#<n> OVERHEATED
408 STORAGE BOX
#<n> POWER SUPPLY
OK
409 STORAGE BOX
#<n> POWER SUPPLY
FAILED
410 STORAGE BOX
#<n> POWER SUPPLY
ADDED
411 STORAGE BOX
#<n> POWER SUPPLY
REMOVED
54
LCD panel and message descriptions
Type
Description
Error
A fan in the specified
storage enclosure is not
operating at full efficiency.
The fan may eventually fail.
Informational
An fan in the specified
storage enclosure has been
hot-added.
Informational
A fan in the specified
storage enclosure has been
removed.
Informational
The temperature in the
specified storage enclosure
is now back in the normal
operating range.
Error
The temperature in the
specified storage enclosure
is starting to exceed the
normal operating range.
Error
The temperature in the
specified storage enclosure
has exceeded the safe
operating range.
Informational
The power supply in the
specified storage enclosure
that was previously marked
as failed or degraded is
now operating normally.
Error
A power supply in the
specified storage enclosure
has failed.
Informational
A power supply in the
specified storage enclosure
has been added.
Informational
A power supply in the
specified storage enclosure
has been removed.
Action
Check all fans and ensure
they are operating. Any
failed fans should be
replaced.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow
and cooling ability of the
MSA.
The MSA should be powered
off as soon as possible
and immediately after
that, the enclosure should
be powered off, to avoid
hardware failure.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow
and cooling ability of the
MSA.
Check all power supplies and
ensure they are operating.
Any failed power supplies
should be replaced.

Advertisement

Table of Contents
loading

This manual is also suitable for:

353803-b22 - storageworks modular smart array 1000 san starterStorageworks 1000 - modular smart arrayStorageworks 1000

Table of Contents