Electrical Diagram•Technical Data
Electric principle diagram
L: live wire (brown)
N: neutral wire (blue)
E: earth wire ( yellow and green)
DB: display board
PB: power board
SW: 10-core signal wire
RY1 and RY2: relays
CD: coil for electricity leakage
detection
MT: manual reset temperature
controller
EH: electrical heater
CP: circulation pump
TS1: temperature sensor for the
water tank
TS2: temperature sensor for the
collector
N : sign of pole N of relay
Technical Data
Volume of storage water tank
Waterproof level of storage water tank
Waterproof level of solar station
Rated internal pressure
Dimension of storage water tank (mm)
Dimension of solar station (mm)
Daylighting area of solar collector
Maximum water supply pressure
Rated voltage
Frequency
Electric assistant heating power
Notice
In above parameters, the difference of the daylighting area for solar collector is less
than or equal to 3%, the difference of the volume for the storage water tank is less
than or equal to 3%, and the difference of the dimension for the storage water tank is
less than or equal to 10%.
14
Haier solar water heater
SW
CD
L
E
N
PB
Model
DB
MT
N
RY1
RY2
PJF2-200
200L
I PX1
I PX1
0.70MPa
600×638×1250
600×638×1720
370×292×145
3.8m
2
0.45MPa
220V~230V
50Hz
2600W
TS1
TS2
EH
CP
PJF2-300
300L
5.7m
2