Operation Methods - Haier PJF2-200 Operating Instruction

Solar water heater
Table of Contents

Advertisement

Operation methods

Under various working mode, the operations are as follows:
The solar heating mode is as follows:
1
Press the button
2
Press the button
, then B twinkles, press the button
3
Press the button
temperature difference value of circulation pump. The setting range is from 5°C to 30°C
with the default value 8°C.
Directions
Q
In solar energy heating mode, temperature difference between solar collector output
vent and water storage tank is used to control operation of circulation pump through
which hot liquid in the solar collector flows into water storage tank and cold liquid in
the bottom of water storage tank flows into solar collector for circulation. If temperature
at the output vent of solar collector is lower than 120°C temperature of water storage
tank is no more than 85°C and the temperature difference is higher than the set
temperature difference of circulation pump, then circulation pump starts to work.
When temperature difference is lower than 3°C, then circulation pump stops working.
It is suggested that the set temperature difference of circulation pump shall be 15°C
in summer and 8°C in winter.
The presetted heating mode is as follows:
1
Set the dated time 1 .
Press the button
2
Press the button
, then B twinkles, press the button
3
Set the dated time 2 . The setting method is same to setting method of time 1 . Repeat the
operations in 1 and 2.
4
Press the button
temperature for electric heating. The setting range is from 30°C to 75°C with the default
value 65°C.
Directions
Q
After setting the dated time and temperature, the system will heat water to the dated
temperature before dated time. When it is the dated time, the system will maintain the
temperature for 30 minutes; while the current temperature is 5°C lower than the set
temperature, it will start the electric heating. During the heating course of dated time,
staged and temporary heating is utilized. Absorb solar energy in priority. When solar
heating can not realize dated temperature, start electric heating for supplement. Thus
presetted heating needs operation in longer advance. It is normal phenomenon.
If it is intended to date one time, set the two same dated time.
, then A twinkles, press the button
again, then A displays "L" and B twinkles; press the button
, then A twinkles, press the button
again, then B twinkles; press the button
Directions for use
to set the current time, "hour" .
to set the current time, "minute" .
to set the current time, "hour" .
to set the current time, "minute" .
to set the dated
Haier solar water heater
to set
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pjf2-300

Table of Contents