Circuit Connection - Haier PJF2-200 Operating Instruction

Solar water heater
Table of Contents

Advertisement

Circuit connection

Circuit connection of water storage tank
1
Connect respectively L end (brown) and N end (blue) of wire of water storage tank with L
end and N end of relay. ( N label of relay represents the N electrode of power)
2
Connect temperature sensor of water storage tank with corresponding interface on the
power plate. Insert properly.
3
Fix the grounding wire of water storage tank on the grounding plate of solar station with
grounding bolts.
4
Disassemble wire clamp and fix and press wire connection of water storage tank.
Solar collector
sensor interface
Water storage tank
sensor interface
Signal wire interface
of Display board
Creepage detection
coil interface
Clamp for holding
the wire
Earth plate
Schematic diagram of power
plate interface of solar station.
Notice
• The nominal cross-sectional area of the wires shall not less than 1.5mm
identified by the colour combination green/yellow shall only be used for grounding
conductors.
• The wires shall provide non-detachable lining or non-detachable bushing.
• The wires shall be protected so that they do not come into contact with hot surface,
wet, or significant amounts of ultraviolet radiation except the wires are suitable for the
conditions.
Installation introduction
Relay output
L end
Wire interface
of water pump
Relay output
N end
Relay output
N label
2
. Conductors
Haier solar water heater
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pjf2-300

Table of Contents