Installation of Storage Water Tank

• Determine and install the storage water tank according to the requirement of users
together with the actual situation.
• Add one corrugated pipe according to the distance between the solar station and the
storage water tank (it shall not be greater than 0.6m), to connect the circular outlet of the
storage water tank and the circular inlet under the solar station.
• Connect with various pipe fittings at the temperature pressure valve, cold water inlet
and hot water outlet.
• Connect the temperature pressure valve on the water tank top. Connect a drainpipe
on the valve. The drainpipe is to be installed in a continuously downward direction and
in a frost-free environment. The valve can drain water out under high temperature and
pressure condition to avoid hazards. At any time the drainpipe can't be blocked.
• The check valve shall be installed at the cold water inlet of the storage water tank, and the
direction of the check valve shall be consistent with the water flow.
• If the water temperature in the storage water tank rises, some water- drop will flow out
from the pressure relief hole of the temperature pressure valve, which is a normal
situation. If your water heater is not installed near to the sewer. It is suggested to install
the drain pipe of the temperature pressure valve, to prevent the spatter indoors. The
drain pipe must be left open to the atmosphere.
• Connect the power cable of the storage water tank and the sensor to the correct position
of the power panel for the solar station.

Installation of the solar station

1
Before installation, determine the specific installation position according to the
requirements of user.
2
According to the positions and distance of the hanger holes on the back of solar station,
drill two holes in the wall with percussion drill. The hole is 70mm in depth and 9mm in
diameter. Then fix it on the wall with two expansion bolts.
3
Align the hanger holes on the back of solar station to the hook on the hanger and hang the
solar station on the hanger.
4
Screw off bolts on the bottom shell of solar station, open its front shell and connect it to
the heat circulation system (all the inlet and outlet vents of solar station are G1/2" female
standard thread).
Notice
Installation position on the wall of
installation hanger of solar station
must be fixed properly and wall
supporting load must be two
times of weights of solar station.
Installation introduction
The hanger holes on
the back of solar station
Small expansion bolt
Haier solar water heater
Hanger of
solar station