Technical specifications
Model
Tank
Total water capacity
Rated voltage/ frequency
Tank max pressure
Corrosion protection
Waterproof grade
Performance (20°C/15°C Ambient air temperature, 15°C -55°C water temperature)
COP*@ 20°C/15°C
Power input of electric element
Rated power input of heat pump
Maximum power input of heat pump
Maximum power input
Average heating capacity by heat pump
Heating water capacity
Heating up time (15
Default temperature setting
Temperature setting range- with heater
Max temperature of the heat pump only
Max working pressure of refrigerant
Refrigerant type / weight
Sound pressure level *@ 1m
Ambient temperature for heat pump
and element
Ambient temperature of heat pump
Dimension and connections
Water inlet and outlet connection
TPR valve connection
Drain & Water inlet connection
Product Dimensions
Packing dimension with pallet
Net/Gross weight
Filled weight of the appliance
* The COP was measured under test conditions with an ambient air temperature of 20˚C/15˚C
(Dry Bulb/Wet Bulb) and heating of the water from 15˚C to 55˚C during water heater operation.
* The noise level was measured at 1 m from the water heater during a Noise Test conducted to
Standard GB/T 23137 in a hemi-anechoic chamber within a laboratory.
-55
)
HP200M1-U1
195L
220-240V/50Hz
700kPa
Magnesium rod
IPX4
4.49
1500W
430W
750W
2250W
2000W
42L / h
4.6h
60°C
35°C – 75°C
65°C
1.0/3.3MPa
R290/0.34kg
43dB(A)
-7~45°C
-7~45°C
Rp ¾"
Rp ¾"
Rp ¾"
600*630*1658mm
736*695*1940mm
91/116kg
286kg
9
HP250M1-U1
246L
220-240V/50Hz
700kPa
Magnesium rod
IPX4
4.48
1500W
430W
750W
2250W
2000W
42L / h
5.8h
60°C
35°C – 75°C
65°C
1.0/3.3MPa
R290/0.34kg
43dB(A)
-7~45°C
-7~45°C
Rp ¾"
Rp ¾"
Rp ¾"
600*630*1951mm
736*695*2250mm
106/128kg
352kg