Viewfinder Adjustment; External Monitor Adjustment; Back Focus Adjustment - JVC GY-DV500E - Pal Professional Dv Camcorder Instructions Manual

Dv camcorder
Hide thumbs Also See for GY-DV500E - Pal Professional Dv Camcorder:
Table of Contents

Advertisement

6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-2 Viewfinder Adjustment

1.
Eyepiece
1.
2.
Eyepiece
focusing ring
1.
3.
3.
CONT
BRIGHT

6-3 External Monitor Adjustment

Display the camera built-in color bar signal on the video monitor and adjust the colors, contrast and brightness.
1.
Connect a color video monitor to the MONITOR OUT
connector of the GY-DV500.
2.
Set the OUTPUT switch to BARS to output the color bar
signal (SMTPE type color bars).
3.
Set the monitor's BLUE CHECK function to ON so that the
screen turns entirely blue.
4.
Adjust the CHROMA control of the monitor so that there is
no difference in brightness between the color bars 1 and
8, 7 and D.
5.
With the BLUE CHECK function ON, adjust the PHASE
control of the monitor so that there is no difference in
brightness between the color bars 3 and 0, 5 and B.
6.
If the phase control adjustment above causes a difference
in brightness between the color bars 1 and 8, 7 and D,
start again from the CHROMA control adjustment in step 4 .
7.
Set the monitor's BLUE CHECK function to OFF to switch
the monitor back to the standard screen (R, G and B will all
appear).
8.
Use the monitor's brightness control to adjust so that the
color bars H and I disappear but J is visible.
SMTPE type color bars
White
Yellow
Cyan
Green Magenta
Red
Blue
1
2
3
4
5
6
7
Blue
Black Magenta Black
Cyan
Black
White
D
8
9
0
A
B
C
Black
White
Black
E
F
G
H I J K
1.
Adjust the position and angle of the viewfinder.
2.
Diopter adjustment
Rotate the eyepiece focusing ring until the viewfinder screen
image is clearly visible.
3.
Brightness and contrast adjustment
When the ambient brightness changes, etc., the brightness
and contrast of the viewfinder screen can be adjusted with
the BRIGHT and CONT controls.
1.
Connect a colour video monitor to the MONITOR OUT
connector of the GY-DV500.
2.
Set the OUTPUT switch to BARS to output the colour bar
signal (EBU type colour bars).
3.
Set the monitor's BLUE CHECK function to ON so that the
screen turns entirely blue.
4.
Adjust the CHROMA control of the monitor so that there is
no difference in brightness between the colour bars 1 and
7.
5.
With the BLUE CHECK function ON, adjust the PHASE
control of the monitor so that there is no difference in
brightness between the colour bars 3 and 5.
6.
If the phase control adjustment above causes a difference
in brightness between the colour bars 1 and 7, start again
from the CHROMA control adjustment in step 4 .
7.
Set the monitor's BLUE CHECK function to OFF to switch
the monitor back to the standard screen (R, G and B will all
appear).
EBU type colour bars
1
2
3
4
5
6
7
The colour bar screen has a configuration as shown above.
The description hereinafter refers to the positions in the colour bar
screen using the numbers.
6. SETTING AND ADJUSTMENTS BEFORE SHOOTING

6-4 Back Focus Adjustment

3.
4. 6.
RET
Siemens star chart
8
43
44
It is only necessary to perform this when the lens is attached
5.
for the first time or when focusing is not correct in both the
telephoto and wide-angle positions. Adjust the viewfinder for
sharpness first.
It is easier to adjust back focus when the subject is more
than 3 meters from the camera.
The optimal subject for this adjustment is a Siemens star
chart.
M
A
W
T
1.
Set the IRIS mode switch to M (Manual).
2.
Set the zoom mode to MANU (Manual).
3.
1.
Open the iris ring. If the illumination is too strong, reduce it
or move to a darker place.
4.
Turn the zoom lever until the lens is at the maximum
telephoto position.
5.
Bring the subject into focus.
6.
Set the lens to maximum wide-angle.
7.
Loosen the back focus ring retaining knob.
2.
7. 8. 10.
8.
View the same subject and adjust the back focus ring for
the best possible focus.
9.
Repeat steps 4. through 8. about three times for fine
adjustment until the subject remains in focus in both the
telephoto position and the wide-angle position.
10.
Tighten the back focus ring retaining knob to secure the
ring.
Memo:
ACCU FOCUS can also be used in the above step 3 .

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-dv500

Table of Contents