Maintenance

About the lamps

CAUTION
The product's light sources are mercury lamps that light at increased internal pressure. Be
sure to fully understand the following characteristics of the lamps and handle them with
extreme care.
The lamps may burst with a loud noise due to impact or deterioration, or fail to light at
the expiration of its life.
How long it takes before the lamps burst or the life expires may vary greatly by lamp.
Some may burst shortly after first use.
Burst is likely to happen if the lamps are used after the replacement period has
elapsed.
When a lamp bursts, the broken pieces of glass may get inside the product or be released
outside from the openings for ventilation.
When a lamp bursts, a slight amount of mercury gas enclosed in the lamp along with
glass dust may be released from the openings for ventilation.
Immediately replace the lamp when a sign appears on the screen.
When the replacement time approaches, a message will appear on the screen.
The risk of burst will increase if a lamp is continuously used without being replaced.
Frequently check the used hours and prepare spares when the replacement time
approaches. (Refer to "Usage time" in the "Status display"
When a lamp is broken
If glass components, including a lamp or lens, should break, handle the broken pieces
with care to avoid injury and contact your dealer for repair service.
In the event of lamp burst, unplug the product from the wall outlet, leave and completely
ventilate the room. Then, thoroughly clean the area around the projector and discard
any edible items placed in that area.
When a lamp bursts, consult a doctor if glass dust or mercury gas gets into your eyes
or you breathe it.
p.59
)
64

Replacing the lamps

When a lamp reaches the end of it's usable life, the following message is displayed.
Replace the lamp.
The projection lamps should be replaced when they burn out. They should only be replaced
with a specified replacement part, contact your local dealer if unsure.
CAUTION:
The lamp contains a certain amount of mercury and should be disposed of according to
local ordinance regulations.
Avoid touching the glass surface of the new lamp: doing so may shorten its operation
life.
If the lamp's useful life ends and projector could not turn on over 2100 hours, please
have the projector serviced.
Notes
The lamps are positioned differently. Use extra caution not to force the lamps when
replacing.
Installation of both lamp modules (Lamp 1 and Lamp 2) is required to operate the
projector in dual or single lamp mode. If only a single lamp module is installed, the
projector's lamp will not turn on and will appear as a lamp failure.
WARNING
If the projector is mounted on the ceiling, it is strongly recommended that you
contact a Toshiba dealer when the lamp has to be exchanged. Do not attemp to
replace the lamp by yourself.
If you uncover the lamp while the projector is mounted on a ceiling, there may
be a danger of damage from falling pieces of glass if the lamp is broke, resulting
in possible injury. In addition, viewing at high elevations can also be potentially
hazardous. Do not attemp to replace the lamp by yourself.
Always use lamp "TLPLW25" (sold separately) when replacing the lamp.
Using a lamp other than the one specified may cause a malfunction or damage to the
unit due to the difference in the connector shape or the lamp rate.
CAUTION
If you have been using the projector, the lamp will be very hot, and may cause
burn injuries.
Wait 1 hour or longer for the lamp to cool before replacing it.
If the lamp should break, please handle with care to avoid injury due to broken
pieces and contact your dealer for repair service.