HIKVISION DS-K1T809 Series User Manual
HIKVISION DS-K1T809 Series User Manual

HIKVISION DS-K1T809 Series User Manual

Access control terminal

Advertisement

Quick Links

DS-K1T809 Series Access Control Terminal
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-K1T809 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HIKVISION DS-K1T809 Series

  • Page 1 DS-K1T809 Series Access Control Terminal User Manual...
  • Page 2: Regulatory Information

    DS-K1T809 Series Access Control Terminal User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 3: Eu Conformity Statement

    DS-K1T809 Series Access Control Terminal User Manual EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union.
  • Page 4 DS-K1T809 Series Access Control Terminal User Manual rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et...
  • Page 5: Safety Instruction

    DS-K1T809 Series Access Control Terminal User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death.
  • Page 6 Improper use or replacement of the battery may result in hazard of explosion. Replace with the ● same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. You can view the device License via the website: http://opensource.hikvision.com/Home/List? ● id=46.
  • Page 7: Available Models

    DS-K1T809 Series Access Control Terminal User Manual Available Models The access control terminal contains the following models: Product Name Model Access Control Terminal DS-K1T809MWX DS-K1T809EWX...
  • Page 8: Table Of Contents

    DS-K1T809 Series Access Control Terminal User Manual Contents Chapter 1 Appearance ........................ 1 Chapter 2 Installation ......................... 2 2.1 Installation Environment ......................2 2.2 Surface Mounting ........................2 Chapter 3 Device Wiring ......................6 3.1 External Device Wiring ......................6 Chapter 4 Operate on the Device ....................
  • Page 9 DS-K1T809 Series Access Control Terminal User Manual 5.3.1 Time Settings ....................... 16 5.4 Overview ..........................16 5.5 Configuration ........................17 5.5.1 View Device Information ..................... 17 5.5.2 Time Settings ....................... 17 5.5.3 Set DST ........................19 5.5.4 Change Administrator's Password on Mobile Web ............. 19 5.5.5 Network Settings ......................
  • Page 10: Chapter 1 Appearance

    DS-K1T809 Series Access Control Terminal User Manual Chapter 1 Appearance Refer to the following contents for detailed information of the access control terminal: Figure 1-1 Access Control Terminal Note The pictures here are for reference only.
  • Page 11: Chapter 2 Installation

    DS-K1T809 Series Access Control Terminal User Manual Chapter 2 Installation 2.1 Installation Environment The minimum bearing weight of the wall or other places should be 3 times heavier than the ● device weight. • Please prepare the following tools and accessories: screwdriver (self purchased), screws, ●...
  • Page 12 DS-K1T809 Series Access Control Terminal User Manual Figure 2-2 Insert Plastic Sleeve 3. Make sure the cables are threaded through the hole. Figure 2-3 Thread Cables 4. Secure the mounting plate on the gang box with two supplied screws (PA4X25-SUS).
  • Page 13 DS-K1T809 Series Access Control Terminal User Manual Figure 2-4 Secure Mounting Plate 5. Complete the wiring. See the wiring diagram for details. Figure 2-5 Complete Wiring 6. Hang the device into the plate from top to bottom. Secure the device on the mounting plate...
  • Page 14 DS-K1T809 Series Access Control Terminal User Manual Figure 2-6 Secure Device...
  • Page 15: Chapter 3 Device Wiring

    DS-K1T809 Series Access Control Terminal User Manual Chapter 3 Device Wiring 3.1 External Device Wiring Wire the external device. The wiring diagram is as follows. Figure 3-1 External Device Wiring Note Use a DC 12 V power supply. Do not connect the device directly to the 220 V mains.
  • Page 16: Chapter 4 Operate On The Device

    DS-K1T809 Series Access Control Terminal User Manual Chapter 4 Operate on the Device 4.1 Common Commands Table 4-1 Common Commands Description Module Operation Command Description Activate Device Activate [*][0][#] [Programming The 6 to 8 digits Password (6 to 8 programming...
  • Page 17: Basic Commands

    DS-K1T809 Series Access Control Terminal User Manual Module Operation Command Description save the added card to the user code location. Delete User Card [02] [Swipe Card]... Add User Cards in [01] [User Code (4 Batch Digits )](Optional) [Swipe Card 1][Swipe Card 2][Swipe Card 3]...
  • Page 18: Enter And Exit Programming Mode

    DS-K1T809 Series Access Control Terminal User Manual Prompts Description Indicator Prompt Audio Description Light is solid green. The buzzer rings for 3 s. Activated , and in normal mode (not programming mode). Light flashes red slowly for 3 The buzzer rings for 5 times Activating failed.
  • Page 19: Other Common Commands

    DS-K1T809 Series Access Control Terminal User Manual Swipe Functional Card After swiping the functional card in the card swiping area, you can directly enter the programming mode. See Set Functional Card for adding details. 4.3 Other Common Commands 4.3.1 Open Door There are two ways to open door: enter the password, or swipe user card.
  • Page 20: Set Functional Card

    DS-K1T809 Series Access Control Terminal User Manual Add User Card in Batch:[01] [User Code (4 Digits )](Optional) [Swipe Card 1][Swipe Card 2][Swipe Card 3]... Note If you enter a user code before adding a card, the location of the added user card is under this ●...
  • Page 21: Delete Card

    DS-K1T809 Series Access Control Terminal User Manual Command of Adding Adding Card: [06] [Swipe Card]. Command of Deleting Adding Card: [07][#]. Note After swiping the adding card to enter the programming mode, if the device is not operated for 30 s, it will exit programming mode.
  • Page 22: Set Voice Parameters

    DS-K1T809 Series Access Control Terminal User Manual 4.4.2 Set Voice Parameters You can set whether to enable the button sound and authentication prompt audio through the command. Command: [12] [Data Bit 1] [Data Bit 2] [#]. Data Bit 1: Indicates whether to enable the button sound, which is a one digit number. "0" means the button sound is disabled, and "1"...
  • Page 23: Restart Device

    DS-K1T809 Series Access Control Terminal User Manual 4.4.6 Restart Device You can restart the device by command. Command: [17] [Programming Password (6 to 8 Digits )] [#]. 4.4.7 Restore to Factory Settings You can restore the device to factory settings by command.
  • Page 24: Chapter 5 Configure The Device Via The Mobile Web

    DS-K1T809 Series Access Control Terminal User Manual Chapter 5 Configure the Device via the Mobile Web The device supports activation and operation through device-side commands. It also supports activation and operation on the mobile phone by connecting to the device hotspot. (If it is activated through the mobile phone, it cannot be operated through the device.
  • Page 25: Quick Operation Via Web Browser

    DS-K1T809 Series Access Control Terminal User Manual Enter the device IP address in the address bar of the mobile browser and press Enter to enter the login page. Enter the device user name and the password. Tap Login. 5.3 Quick Operation via Web Browser 5.3.1 Time Settings...
  • Page 26: Configuration

    DS-K1T809 Series Access Control Terminal User Manual Network Status You can view the connected status of wireless network and Hik-Connect. Basic Information You can view the model, serial No. and firmware version. 5.5 Configuration 5.5.1 View Device Information View the device name, language, model, serial No., version, number of channels, IO input number, number of alarm input and output, Mac address, factory information and device capacity, etc.
  • Page 27 DS-K1T809 Series Access Control Terminal User Manual Figure 5-1 Time Settings Tap Save to save the settings. Time Zone Select the time zone where the device is located from the drop-down list. Time Sync. Mode Manual You can set the device time manually, or enable Sync. with Phone Time.
  • Page 28: Set Dst

    DS-K1T809 Series Access Control Terminal User Manual Set the NTP server's IP address, port No., and interval. 5.5.3 Set DST Steps 1. Tap → System Settings → Time Settings , to enter the settings page. Figure 5-2 DST 2. Tap Enable DST.
  • Page 29: Network Settings

    DS-K1T809 Series Access Control Terminal User Manual change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. 5.5.5 Network Settings Set Device Hotspot Set the device hotspot, and mobile phone can connect to the device to enter the mobile browser.
  • Page 30: User Management

    DS-K1T809 Series Access Control Terminal User Manual Figure 5-3 Wiegand Page 2. Enable Wiegand to enable the Wiegand function. 3. Set a transmission direction. Note The device can connect an external access controller. And the two devices will transmit the card No.
  • Page 31 DS-K1T809 Series Access Control Terminal User Manual Figure 5-4 User Management 2. Add user. 1) Tap+. 2) Set the following parameters. Employee No. Enter the employee No. The Employee No. cannot be 0 or exceed 32 characters. It can be a combination of uppercase letters, lowercase letters and numbers.
  • Page 32: Search Event

    DS-K1T809 Series Access Control Terminal User Manual Set the user permission as long-term effective, or set the start date and end date of user permission. User Type Select your user role. Card Add card. Tap Card, then tap +. Enter the card No. or swipe the card to read card No., and then select Card Type.
  • Page 33 DS-K1T809 Series Access Control Terminal User Manual Figure 5-5 Set Authentication Parameters 2. Tap Save. Terminal Select the terminal. Authentication Type Select an authentication type according to your actual needs from the drop-down list. Authentication Interval You can set the authentication interval of the same person when authenticating. The same person can only authenticate once in the configured interval.
  • Page 34 DS-K1T809 Series Access Control Terminal User Manual Max. Interval When Entering Password You can set the Max. timeout period for password entry, after which the password input will be invalid. Enable Card No. Reversing If this function is enabled, the card reader will reverse the order of the card No. after reading them.
  • Page 35 DS-K1T809 Series Access Control Terminal User Manual Figure 5-6 Door Parameters Settings Tap Save to save the settings after the configuration. Door Name You can create a name for the door. Door Opening Duration(s) Set the door open duration. Exit Button Type...
  • Page 36: Upgrade And Maintenance

    DS-K1T809 Series Access Control Terminal User Manual You can set the exit button as Remain Open or Remain Closed according to your actual needs. By default, it is Remain Closed. Door Opening Timeout Alarm Threshold An alarm will be triggered if the door has not been closed within the configured time duration.
  • Page 37: Restore Parameters

    DS-K1T809 Series Access Control Terminal User Manual Note Do not power off during the upgrading. Restore Parameters → Default . Restore to Default Settings The device will restore to the default settings, except for the device network parameters and the user information.
  • Page 38: Appendix A. Legal Information

    ● Products described in this Document, which may include licenses obtained from third parties. Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part ● of this Document may be excerpted, copied, translated, or modified in whole or in part by any means without written permission.
  • Page 39: Data Protection

    LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY ●...
  • Page 40: Appendix B. Symbol Conventions

    DS-K1T809 Series Access Control Terminal User Manual Appendix B. Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury.
  • Page 41: Appendix C. Dimension

    DS-K1T809 Series Access Control Terminal User Manual Appendix C. Dimension Figure C-1 Dimension Note The pictures here are for reference only.
  • Page 42 UD39498B...

This manual is also suitable for:

Ds-k1t809mwxDs-k1t809ewxDs-k1t809mx

Table of Contents