Hide thumbs Also See for JSY1000 Series:

Advertisement

Non Plug-in
Compact 5-Port Solenoid Valve
Size reduction possible thanks to a flow increase
This leads to space saving, weight
reduction, and a large flow rate.
32
Ø
*
1
Possible to drive
JSY1000
6.4
A, B port size: Ø 2, Ø 4, Ø 6
Ø 20
320
Ø 32
110
Ø 50
100
300
500
Cylinder speed [mm/s]
Ø 6 One-touch fitting
Refer to pages 5 to 16 for detailed conditions regarding the above cylinder speed.
JSY1000
JSY1000/3000/5000
bore cylinders Possible to drive
JSY3000
mm
A, B port size: Ø 4, Ø 6, Ø 8
590
Ø 40
Ø 50
Ø 100
100
JSY3000
50
Ø
*
1
bore cylinders Possible to drive
10
mm
520
430
120
300
500
Cylinder speed [mm/s]
Ø 8 One-touch fitting
Series
New
New
RoHS
80
Ø
*
1
bore cylinders
JSY5000
15
A, B port size: Ø 6, Ø 8, Ø 10, Ø 12
*1 The cylinder speed is 300 mm/s
Ø 50
Ø 80
320
110
Ø 140
100
300
500
Cylinder speed [mm/s]
Ø 12 One-touch fitting
An M12 connector
New
New
has been added.
(JSY5000 only)
16
p.
JSY5000
CAT.EUS11-113A-UK
mm
600

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JSY1000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks JSY1000 Series

  • Page 1 Non Plug-in Compact 5-Port Solenoid Valve Size reduction possible thanks to a flow increase This leads to space saving, weight RoHS reduction, and a large flow rate. Ø Ø Ø Possible to drive bore cylinders Possible to drive bore cylinders Possible to drive bore cylinders JSY1000 JSY3000...
  • Page 2 Valve width [mm] Power Consumption JSY3000/5000 JSY1000 JSY3000/5000 With power Standard saving circuit *2 JSY1000 series available as power saving type only. * DIN terminal: 0.45 W Power consumption is reduced by power JSY3000 saving circuit. Applied voltage 24 V Power consumption is decreased to approx.
  • Page 3 Compact 5-Port Solenoid Valve JSY1000/3000/5000 Series Non Plug-in Space Saving Volume % reduction Max. Weight % reduction Max. Volume [cm Weight [g] JSY1000 reduction reduction SY3000 JSY3000 reduction reduction SY5000 JSY5000 reduction reduction SY7000 1160 4-Position Dual 3-Port Valve Available Bottom ported is prepared (A, B port).
  • Page 4 Compact 5-Port Solenoid Valve JSY1000/3000/5000 Series Non Plug-in Series Variations Sonic conductance Manifold Options Port size Valve Options C [dm /(s·bar)] A, B port 4/2g5/3 (A/BgEA/EB) Type of actuation Thread piping One-touch fitting P, E 4 (A), port 2 (B) M3 M5 1/8 1/4 Ø...
  • Page 5 C O N T E N T S Optimum Actuation Size Chart of Air Cylinder··············· p. 5 Valve Construction ······················································ p. 11 Valve Specifications Valve Replacement Parts ············································ p. 12 (Specifications, Response Time, Weight)······················ p. 9 Manifold Metal Base Non Plug-in Type 40 Side Ported/Type 41 Bottom Ported p.
  • Page 6 Optimum Actuation Size Chart of Air Cylinder For JSY1000, A, B port: Ø 4 Horizontal Vertical Average speed [mm/s] Ø 6 CJ2 series Pressure: 0.5 MPa Ø 10 Load ratio: 50 % Stroke: 60 mm Ø 16 Ø 20 Ø 25 CM2 series Pressure: 0.5 MPa Load ratio: 50 %...
  • Page 7 Optimum Actuation Size Chart of Air Cylinder For JSY1000, A, B port: Ø 6 Horizontal Vertical Average speed [mm/s] Ø 6 CJ2 series Pressure: 0.5 MPa Ø 10 Load ratio: 50 % Stroke: 60 mm Ø 16 Ø 20 Ø 25 CM2 series Pressure: 0.5 MPa Load ratio: 50 %...
  • Page 8 Optimum Actuation Size Chart of Air Cylinder For JSY3000, A, B port: Ø 8 Horizontal Vertical Average speed [mm/s] Ø 20 Ø 25 CM2 series Pressure: 0.5 MPa Load ratio: 50 % Stroke: 300 mm Ø 32 Ø 40 Ø 50 Ø...
  • Page 9 Optimum Actuation Size Chart of Air Cylinder For JSY5000, A, B port: Ø 12 Horizontal Vertical Average speed [mm/s] 1000 CM2 series Pressure: 0.5 MPa Ø 40 Load ratio: 50 % Stroke: 300 mm Ø 50 Ø 63 CA2 series Pressure: 0.5 MPa Load ratio: 50 % Stroke: 500 mm...
  • Page 10: Valve Specifications

    Refer to page 45-1 for the fixation of DIN rail mounting type manifold. *2 JSY1000 series available as power saving type only. Standard type (without power saving circuit) cannot be selected. *3 The type with a power-saving circuit is not available for the DIN terminal, M8 connector, and M12 connector types.
  • Page 11 JSY1000/3000/5000 Series Valve Specifications Response Time/Valve Weight Response time [ms] (at 0.5 MPa) * Weight [g] Standard Series Seal type Model Type of actuation With light/surge W/WA voltage suppressor plug terminal connector connector connector Z type JSY1140T 2-position single JSY1240T 2-position double JSY1000 —...
  • Page 12 JSY1000/3000/5000 Series Valve Construction Rubber Seal 2-position single 2-position double (EA) (EB) (EA) (EB) 2-position single 2-position double (A)4 2(B) (A)4 2(B) (EA)5 3(EB) (EA)5 3(EB) 3-position closed centre/exhaust centre/pressure centre 4-position dual 3-port valve (EA) (EB) (EA) (EB) 3-position closed centre 3-position exhaust centre 4-position dual 3-port valve N.C.
  • Page 13 JSY1000/3000/5000 Series Valve Replacement Parts How to Order Pilot Valves For JSY1000 How to replace pilot valves V050 Gasket * Pilot valve Coil type With power saving circuit Rated voltage Adapter plate 24 VDC Clip Clip part no. JSY11V-46-1A (10 pcs.) Electrical entry Concave L plug...
  • Page 15 JSY1000/3000/5000 Type Series Metal Base Non Plug-in Manifold Specifications Manifold type Non plug-in metal base SUP/EXH port type Common SUP/EXH Valve stations 2 to 20 stations JSY1000 JSY3000 1(P), 3/5(E) port JSY5000 M3 x 0.5, M5 x 0.8 JSY1000 Ø 2 One-touch fitting, Ø 4 One-touch fitting, Ø 6 One-touch fitting Port size M5 x 0.8, 1/8 JSY3000...
  • Page 16 Type 40 Metal Base Non Plug-in Side Ported JSY1000/3000/5000 Series Type 41 Bottom Ported Internal Pilot How to Order Manifolds JJ5SY 3 D C6 M a d e t o Made to Order O r d e r (Refer to page 40 for details.) Specification External pilot Series...
  • Page 17  (Continuous duty type) 3-position Exhaust center Pressure center * For the JSY1000 series, only the power-saving circuit specification is available. (N.C./N.C.) * Be careful of the energising time when the power-saving circuit is selected. 4-position (N.O./N.O.) For details, refer to page 45.
  • Page 18 JSY1000/3000/5000 Series 40/Side Non Plug-in Type Ported JSY1000 Metal Base Port Size: M3, M5 Dimensions: Series JJ5SY1-40 Stations ( Port size M3 (Pitch) P=6.5 40R- Stations M3 x 0.5 [4(A), 2(B) port] [Plug for external pilot] *1 The external pilot (R) should be ordered as Made to Order. * These figures show the “JJ5SY1-40-05B-M5.”...
  • Page 19 JSY1000/3000/5000 Series Metal Base Non Plug-in 40/Side Non Plug-in Type Ported JSY1000 Metal Base Port Size: Ø 2, Ø 4/Fixed Dimensions: Series JJ5SY1-40 Stations ( One-touch fitting Ø 2 (Pitch) 40R- Stations One-touch fitting [4(A), 2(B) port] [Plug for external pilot] Applicable tubing O.D.: Ø...
  • Page 20 JSY1000/3000/5000 Series 40/Side Non Plug-in Type Ported JSY1000 Metal Base Port Size: Ø 2, Ø 4, Ø 6/Replaceable Dimensions: Series JJ5SY1-40 Stations ( One-touch fitting (Pitch) 40R- Stations One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: Ø 2 (SMC) [Plug for external pilot] : Ø...
  • Page 21 JSY1000/3000/5000 Series Metal Base Non Plug-in 41/Bottom Non Plug-in Type Ported JSY1000 Metal Base Port Size: M3, M5 Dimensions: Series JJ5SY1-41 Stations  *1 The external pilot (R) should be ordered as Made to Order. 4 x M3 x 0.5 thread depth 4 Panel fitting dimensions * These figures show the “JJ5SY1-41-05B-M5.”...
  • Page 22 JSY1000/3000/5000 Series 41/Bottom Non Plug-in Type Ported JSY1000 Metal Base Port Size: Ø 2, Ø 4/Fixed Dimensions: Series JJ5SY1-41 Stations  4 x M3 x 0.5 thread depth 4 (For mounting) (Pitch) P=8.5 *1 The external pilot (R) should be ordered as Made to Order. * These figures show the “JJ5SY1-41-05B-C4.”...
  • Page 23 JSY1000/3000/5000 Series Metal Base Non Plug-in 41/Bottom Non Plug-in Type Ported JSY1000 Metal Base Port Size: Ø 2, Ø 4, Ø 6/Replaceable Dimensions: Series JJ5SY1-41 Stations  *1 The external pilot (R) should be ordered 4 x M3 x 0.5 thread depth 4 One-touch fitting as Made to Order.
  • Page 24 JSY1000/3000/5000 Series 40/Side Non Plug-in Type Ported JSY3000 Metal Base Port Size: M5, 1/8 Dimensions: Series JJ5SY3-40 Stations ( Port size M5 40R- Stations (Station 1)------------ (Station n) (Pitch) P=10.5 [Plug for external pilot] (Light/surge voltage suppressor) M5 x 0.8 [4(A), 2(B) port] * The drawing above shows when P, E port entry is D.
  • Page 25 JSY1000/3000/5000 Series Metal Base Non Plug-in 40/Side Non Plug-in Type Ported JSY3000 Metal Base Port Size: Ø 6/Fixed Dimensions: Series JJ5SY3-40 Stations ( 40R- Stations (Station 1)------------ (Station n) (Light/surge voltage suppressor) [Plug for external pilot] * The drawing above shows when P, E port One-touch fitting entry is D.
  • Page 26 JSY1000/3000/5000 Series 40/Side Non Plug-in Type Ported JSY3000 Metal Base Port Size: Ø 4, Ø 6, Ø 8/Replaceable Dimensions: Series JJ5SY3-40 Stations ( 40R- (Station 1)------------ (Station n) Stations (Light/surge voltage suppressor) [Plug for external pilot] (Pitch) One-touch fitting * The drawing above shows when P, E port 19.1 P=11.5 [4(A), 2(B) port]...
  • Page 27 JSY1000/3000/5000 Series Metal Base Non Plug-in 41/Bottom Non Plug-in Type Ported JSY3000 Metal Base Port Size: M5, 1/8 Dimensions: Series JJ5SY3-41 Stations  [4(A), 2(B) port] (Pitch) 41R- Stations P=13.5 Fitting dimensions for panel mounting − + Refer to panel fitting dimensions for details. −...
  • Page 28 JSY1000/3000/5000 Series 41/Bottom Non Plug-in Type Ported JSY3000 Metal Base Port Size: Ø 6/Fixed Dimensions: Series JJ5SY3-41 Stations  (Pitch) One-touch fitting P=10.5 [4(A), 2(B) port] 41R- Stations Applicable tubing O.D.: Ø 6 (SMC) − + 4 x M4 x 0.7 thread depth 4 −...
  • Page 29 JSY1000/3000/5000 Series Metal Base Non Plug-in 41/Bottom Non Plug-in Type Ported JSY3000 Metal Base Port Size: Ø 4, Ø 6, Ø 8/Replaceable Dimensions: Series JJ5SY3-41 Stations  (Pitch) One-touch fitting P=11.5 [4(A), 2(B) port] 41R- Stations Applicable tubing O.D.: Ø 4 (SMC) 4 x M4 x 0.7 thread depth 4 −...
  • Page 30 JSY1000/3000/5000 Series 40/Side Non Plug-in Type Ported JSY5000 Metal Base Port Size: 1/8, 1/4 Dimensions: Series JJ5SY5-40 Stations ( (Station 1)------------ (Station n) 40R- Stations (Light/surge voltage suppressor) [Plug for external pilot] (Pitch) * The drawing above shows when P, E port 19.7 P=16.5 1/4, 1/8...
  • Page 31 JSY1000/3000/5000 Series Metal Base Non Plug-in 40/Side Non Plug-in Type Ported JSY5000 Metal Base Port Size: Ø 8/Fixed Dimensions: Series JJ5SY5-40 Stations ( 40R- Stations (Station 1)------------ (Station n) (Light/surge voltage suppressor) [Plug for external pilot] * The drawing above shows when P, E port entry is D.
  • Page 32 JSY1000/3000/5000 Series 40/Side Non Plug-in Type Ported JSY5000 Metal Base Port Size: Ø 6, Ø 8, Ø 10, Ø 12/Replaceable Dimensions: Series JJ5SY5-40 Stations ( KC10 KC12 40R- Stations (Station 1)------------ (Station n) (Light/surge voltage suppressor) [Plug for external pilot] * The drawing above shows when P, E port One-touch fitting entry is D.
  • Page 33 JSY1000/3000/5000 Series Metal Base Non Plug-in 41/Bottom Non Plug-in Type Ported JSY5000 Metal Base Port Size: 1/8, 1/4 Dimensions: Series JJ5SY5-41 Stations  (Pitch) 41R- Stations P=16.5 1/4, 1/8 4 x M4 x 0.7 thread depth 5 [4(A), 2(B) port] [Plug for external pilot] (For mounting) * The drawing above shows when P, E port entry is D.
  • Page 34 JSY1000/3000/5000 Series 41/Bottom Non Plug-in Type Ported JSY5000 Metal Base Port Size: Ø 8/Fixed Dimensions: Series JJ5SY5-41 Stations  One-touch fitting (Pitch) [4(A), 2(B) port] P=16 41R- Stations Applicable tubing O.D.: Ø 8 (SMC) 4 x M4 x 0.7 thread depth 5 (For mounting) [Plug for external pilot] * The drawing above shows when P, E port entry is D.
  • Page 35 JSY1000/3000/5000 Series Metal Base Non Plug-in 41/Bottom Non Plug-in Type Ported JSY5000 Metal Base Port Size: Ø 6,Ø 8, Ø 10, Ø 12/Replaceable Dimensions: Series JJ5SY5-41 Stations  KC10 KC12 (Pitch) P=16.5 41R- Stations One-touch fitting [4(A), 2(B) port] 4 x M4 x 0.7 thread depth 5 Applicable tubing O.D.:Ø...
  • Page 36 JSY1000/3000/5000 Series Type Metal Base Manifold Exploded Non Plug-in View <JSY1000 series> U side Holding screw Included only with the DIN rail mounting type (with DIN rail) Tightening torque: 0.8 N·m D side Included only with the DIN rail mounting type (Tightening torque for holding screw: 1.4 N·m)
  • Page 37 JSY1000/3000/5000 Series One-touch Fittings, Clip, Port Plate, Tube Releasing Tool Refer to “How to Replace One-touch Fittings” on page 44 for the replacement method.  One-touch Fittings JSY1000 JSY3000 JSY5000 Port size Note Ø 2 KQSY10-C2 — — Ø 4 KQSY10-C4-X1336 KQSY30-C4 —...
  • Page 38 JSY1000/3000/5000 Series Manifold Options  DIN rail dimensions/weight for the JSY1000/3000 metal base Non Plug-in VZ1000-11-1- * After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and specify the number in the box . (10) Rail mounting hole pitch 12.5 60.5...
  • Page 39 JSY1000/3000/5000 Series Manifold Options Caution Tightening torque for mounting screw M1.4: 0.06 N·m (JSY1000) M2: 0.16 N·m (JSY3000) Manifold Options M3: 0.8 N·m (JSY5000) * Refer to page 39 for dimensions. How to Order Blanking Plates  Blanking plate [With two mounting screws] JSY 3 1M 26 1A Used when valve additions are expected or for maintenance.
  • Page 40 * Refer to page 39-1 for dimensions.  SUP stop valve spacer with residual pressure release valve * Only compatible when the JSY1000 series 4(A), 2(B) ports are port size M5 or KC6 [With a base gasket and two mounting screws] JSY11M-50-1A It is used to shut off the supply air to valves individually.
  • Page 41 38-2...
  • Page 42 JSY1000/3000/5000 Series Dimensions: Manifold Options  Blanking plate JSY1000 JSY3000 JSY5000 series series series + − <Type 40> <Type 40> <Type 40>  Individual SUP/EXH spacer JSY1000 JSY3000 JSY5000 series series series One-touch fitting (SUP port, EXH port) Applicable tubing O.D.: Ø 8, Ø 10, Ø 12 One-touch fitting One-touch fitting (SUP port, EXH port)
  • Page 43 Manifold Options Dimensions: Manifold Options  SUP stop valve spacer with residual pressure release valve * Only compatible when the JSY1000 series 4(A), 2(B) ports are port size M5 or KC6 SUP stop valve spacer with residual pressure release valve (Pitch) P = 9.5 (For KC6)
  • Page 44 39-2...
  • Page 45 JSY1000/3000/5000 Series Made to Order M a d e t o O r d e r Please contact SMC for detailed dimensions, specifications, and delivery times. External Pilot How to Order Manifolds JJ5SY Type External pilot How to Order Valves Coil type Pilot type External pilot...
  • Page 46: Specific Product Precautions

    If it is not turned, it can be operated the same way as the non- locking push type. Caution JSY1000 series Mount it so that there is no slippage or deformation in gaskets, and tighten with the tightening torque as shown below.
  • Page 47 If it is not turned, it can be operated the same way as the non- locking push type. Plug position B port A port JSY1000 series Type of actuation N.C. N.O. Locked position (A)4 2(B)
  • Page 48 JSY1000/3000/5000 Series Specific Product Precautions 3 Be sure to read this before handling the products. For safety instructions and 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smc.eu Plug Connector How to Use L/M Plug Connector Caution...
  • Page 49 JSY1000/3000/5000 Series Specific Product Precautions 4 Be sure to read this before handling the products. For safety instructions and 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smc.eu Plug Connector [M12 connector cable] M8 Connector Type (JSY3000/5000), M12 Connector Type (JSY5000)
  • Page 50 JSY1000/3000/5000 Series Specific Product Precautions 5 Be sure to read this before handling the products. For safety instructions and 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smc.eu Surge Voltage Suppressor Caution <For DC>...
  • Page 51 KQ2H 1P, 5EA * It is not possible to replace C2 or C4 fittings with C6 fittings for the KQ2S JSY1000 series. KQ2H * Refer to page 36 for One-touch fitting, clip, and port plate part X, PE KQ2S JJ5SY5-40/41(R) numbers.
  • Page 52 JSY1000/3000/5000 Series Specific Product Precautions 7 Be sure to read this before handling the products. For safety instructions and 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smc.eu Other Tube Brands How to Use DIN Terminal Caution...
  • Page 53 JSY1000/3000/5000 Series Specific Product Precautions 8 Be sure to read this before handling the products. For safety instructions and 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smc.eu M8 Connector Caution 1.
  • Page 55 Compact 5-Port Solenoid Valve JSY1000/3000/5000 Series Non Plug-in Body Ported Single Unit (For Mounting P.E Plate) RoHS Ø Ø Ø Can drive bore cylinders Can drive bore cylinders Can drive bore cylinders JSY1000 JSY3000 JSY5000 Mounting hole P.E plate *1 The cylinder speed is 300 mm/s. Wall mounting is 4(A) An M12 connector has been added.
  • Page 56: Valve Specifications

    (Value in the initial state) *2 JSY1000 series available as power-saving type only. Standard type (without power-saving circuit) cannot be selected. *3 The type with a power-saving circuit is not available for the DIN terminal and M12 connector types.
  • Page 57 JSY1000/3000/5000 Type Series Body Ported Single Unit (For Mounting P.E Plate) Non Plug-in Single Unit Specifications Model Non plug-in, For mounting P.E plate JSY1000 M5 x 0.8 JSY3000 1(P), 3/5(E) port 1/16 JSY5000 Port size JSY1000 M3 x 0.5, M5 x 0.8 JSY3000 4(A), 2(B) port 1/16...
  • Page 58   (Continuous duty type) * For the JSY1000 series, only the power-saving circuit specification is available. * Be careful of the energizing time when the power-saving circuit is selected. For details, refer to page 45. * Power saving circuit is not available in the case of D, Y, W, K type.
  • Page 59 JSY1000/3000/5000 Body Ported Non Plug-in Series Single Unit (For Mounting P.E Plate) 20/Top Body Ported Type Ported JSY1000 Single Unit Port Size: M3, M5 Dimensions: Series 2-position single/L plug connector (L) JSY1120T-5LZ-M5-PE 34.4 M5 x 0.8 [1(P), 5(EA), 3(EB) port] (Light/surge voltage suppressor) 19.4 2 x Ø...
  • Page 60 JSY1000/3000/5000 Series 20/Top Body Ported Type Ported JSY1000 Single Unit Port Size: M3, M5 Dimensions: Series 2-position double/L plug connector (L) JSY1220T-5LZ-M5-PE 34.4 M5 x 0.8 [1(P), 5(EA), 3(EB) port] (Light/surge voltage suppressor) 10.5 2 x Ø 2.7 (For mounting) Approx.
  • Page 61 JSY1000/3000/5000 Body Ported Non Plug-in Series Single Unit (For Mounting P.E Plate) 20/Top Body Ported Type Ported JSY3000 Single Unit Port Size: Rc1/16 Dimensions: Series 2-position single/L plug connector (L) JSY3120-5LZ-R1-PE 47.6 26.4 Rc1/16 [1(P), 5(EA), 3(EB) port] (Light/surge voltage suppressor) 13.2 27.5 2 x Ø...
  • Page 62 JSY1000/3000/5000 Series 20/Top Body Ported Type Ported JSY3000 Single Unit Port Size: Rc1/16 Dimensions: Series 2-position double/L plug connector (L) JSY3220-5LZ-R1-PE 47.6 26.4 Rc1/16 [1(P), 5(EA), 3(EB) port] (Light/surge voltage suppressor) 13.2 2 x Ø 3.2 (For mounting) Approx. 300 126.1 (Lead wire length) Manual override...
  • Page 63 JSY1000/3000/5000 Body Ported Non Plug-in Series Single Unit (For Mounting P.E Plate) 20/Top Body Ported Type Ported JSY5000 Single Unit Port Size: Rc1/8 Dimensions: Series 2-position single/L plug connector (L) JSY5120-5LZ-01-PE 61.7 Rc1/8 [1(P), 5(EA), 3(EB) port] (Light/surge voltage suppressor) 2 x Ø...
  • Page 64 JSY1000/3000/5000 Series 20/Top Body Ported Type Ported JSY5000 Single Unit Port Size: Rc1/8 Dimensions: Series 2-position double/L plug connector (L) JSY5220-5LZ-01-PE 61.7 Rc1/8 [1(P), 5(EA), 3(EB) port] (Light/surge voltage suppressor) 2 x Ø 4.3 (For mounting) Approx. 300 148.9 (Lead wire length) 83.1 Manual override Rc1/8...
  • Page 65 JSY1000/3000/5000 Series Single Unit Parts Nos. Non Plug-in Part number Description Note JSY1000 JSY3000 JSY5000 JSY11V-23-3A JSY31V-23-7A JSY51V-23-7A Valve mounting Part numbers shown on the left screw are for 10 valves. (20 pcs.) (M1.4 x 24.5) (M2 x 27) (M3 x 32) Part numbers shown on the left JSY11M-9P-1A JSY31M-9P-1A JSY51M-9P-1A w Base gasket...
  • Page 66 JSY1000/3000/5000 Series Made to Order M a d e t O r d e r Please contact SMC for detailed dimensions, specifications, and delivery times. Coil type: With power-saving circuit (Continuous duty type) Be sure to select the power-saving circuit type when the JSY3000/5000 series is continuously energized for long periods of time. Be careful of the energizing time when the power-saving circuit is selected.
  • Page 67: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 68 Revision History Edition B - Xxxxxxxxxx Edition C - Xxxxxxxxxx - Xxxxxxxxxxx SMC Corporation (Europe) Austria Lithuania +43 (0)2262622800 www.smc.at office.at@smc.com +370 5 2308118 www.smclt.lt info.lt@smc.com Belgium Netherlands +31 (0)205318888 +32 (0)33551464 www.smc.be info@smc.be www.smc.nl info@smc.nl Bulgaria Norway +359 (0)2807670 www.smc.bg sales.bg@smc.com +47 67129020...

Table of Contents