9-7. Set Sensor Parameter of NCW-3DHPN
Before NCW-3DHPN is used, parameters must be configured.
The parameter value set at configuration tool is written to NCW-3DHPN when the communication is established
for PROFINET.
Note
The sensor parameter can be also set from the WRREC of the PLC function.
However, a value is change to it set by the configuration tool when communication is reestablished
(relinking-up or restarting the power supply). In this case, set the parameter from the WRREC again.
9-7-1. Sensor parameter list
NCW-3DHPN has following sensor parameters.
Sensor parameter setting values are saved in the nonvolatile memory; therefore, NCW-3DHPN can operate with
previous designated parameters after turning on the power supply again.
Axis
Axis Unavailable
For axis-1
sensor
Code Sequence
(Position Data Increase Direction)
Axis Unavailable
For axis-2
sensor
Code Sequence
(Position Data Increase Direction)
◆ Travel direction of the rod
Parameter Name
CYLNUC
CYLNUC MarkⅡ
CW
CCW
Specify "Enable" or "Disable" for the axis.
0: Enable (Default)
1: Disable
Specify the ABSOCODER sensor rotation direction in
which the position data increases.
0: CW (Default)
1: CCW
Specify "Enable" or "Disable" for the axis.
0: Enable (Default)
1: Disable
Specify the ABSOCODER sensor rotation direction in
which the position data increases.
0: CW (Default)
1: CCW
VLS-12.8PRA28
VLS-12.8MHP28
CW
CW
CCW
41
Description
IRS-51.2P
CCW