Table 1-4. LCD Status Messages (continued)
Code
Text
E201F
DRAC Config
E2020
CPU Config
E2021
Memory
Population
E2022
POST Fail
MBE DIMM ## & ## One of the DIMMs in the set
E2110
E2111
SBE Log Disable
DIMM ##
E2112
Mem Spare DIMM
##
E2113
Mem Mirror DIMM
## & ##
Causes
Dell remote access controller
(DRAC) configuration failure.
CPU configuration failure.
Incorrect memory configuration.
Memory population order
incorrect.
General failure after video.
implicated by "## & ##" has
had a memory multi-bit error
(MBE).
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS.
The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS.
They system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS.
Corrective Actions
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
Check screen for specific error
messages.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 110.
Check screen for specific error
messages.
See "Troubleshooting System
Memory" on page 110.
See "Troubleshooting System
Memory" on page 110.
See "Troubleshooting System
Memory" on page 110.
See "Troubleshooting System
Memory" on page 110.