Table 1-6. LCD Status Messages (continued)
Code
Text
E2112
Mem Spare DIMM
##
E2113
Mem Mirror DIMM
## & ##
Fatal NB Mem CRC One of the connections in the
E2118
Fatal SB Mem CRC One of the connections in the
E2119
I1910
Intrusion
I1911
>3 ERRs Chk Log
I1912
SEL Full
ROMB Batt < 24hr Warns predictively that the RAID
W1228
NOTE:
For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 169.
Causes
The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS.
They system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS.
Fully Buffered DIMM (
memory subsystem link on the
Northbound side has failed.
FBD memory subsystem link on
the Southbound side has failed.
System cover has been removed.
LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
System Event Log is full of
events, and is unable to log any
more events.
battery has less than 24 hours of
charge left.
Corrective Actions
See "Troubleshooting System
Memory" on page 124.
See "Troubleshooting System
Memory" on page 124.
See "Troubleshooting System
FBD)
Memory" on page 124.
See "Troubleshooting System
Memory" on page 124.
Information only.
Check the SEL for details on the
events.
Clear the log by deleting event
entries.
Replace RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 96.
About Your System