Advertisement

Quick Links

safe
smart
IM-PN-RX104-EN-v06
Language: English(original)
INSTALLATION
INSTRUCTIONS
Receiver: R17-01
strong
R 1 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R17 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tele Radio R17

  • Page 1 INSTALLATION INSTRUCTIONS Receiver: R17-01 safe smart strong R 1 7 IM-PN-RX104-EN-v06 Language: English(original)
  • Page 2 IMPORTANT! This document is intended for R17 receivers with software version SW0014-21v08 or higher. For receivers with software version SW0014-21v07 or lower, please refer to the installation instructions IM-PN-RX104-A04-EN. ©Tele Radio AB Datavägen 21 SE-436 32 Askim Sweden Phone: +46 (0)31 748 54 60...
  • Page 3: Table Of Contents

    CONTENTS CHAPTER 1: INTRODUCTION 1.1  About this document 1.2  About R17 receiver CHAPTER 2: SAFETY 2.1  Warnings & restrictions CHAPTER 3: TECHNICAL DATA 3.1  Receiver specifications 3.2  Current consumption CHAPTER 4: PRODUCT GENERAL DESCRIPTION 4.1  Receiver description 4.2  echanical installation CHAPTER 5: BOARD DESCRIPTION 5.1  Base board CHAPTER 6: STATUS AND ERROR INDICATIONS 6.1  Function LEDs indication in normal operation...
  • Page 4 CHAPTER 9: WARRANTY, SERVICE, REPAIRS, AND MAINTENANCE CHAPTER 10: REGULATORY INFORMATION 10.1  Europe ANNEX A: INDEX...
  • Page 5: Chapter 1: Introduction

    These Installation instructions have been published by Tele Radio AB and are not subject to any guarantees. The Installation instructions may be withdrawn or revised by Tele Radio AB at any time and without further notice. Corrections and updates will be added to the latest version of the manual. Always download the Installation instructions from our website, www.tele-radio.com, for the latest...
  • Page 6: About This Document

    Tele Radio AB Installation instructions do not include or address the specific instructions and safety warnings of the end product manufacturer. Tele Radio AB products are covered by a warranty against material, construction, or manufacturing faults. See "Chapter 9: Warranty, service, repairs, and maintenance".
  • Page 7: About R17 Receiver

    & usage habits .  R17 receivers have simplex communication with support for duplex and can work in either discontinuous or continuous mode.
  • Page 8: Chapter 2: Safety

    IMPORTANT! Tele Radio AB remote controls are often built into wider applications. These systems should be equipped with:     • a wired emergency stop where necessary     •...
  • Page 9 Installation instructions│ R17│ Chapter 2: Safety RISK OF ELECTRIC SHOCK The receiver must only be opened by qualified installers or authorized personnel. Make sure the power supply is switched off before opening the receiver. Failure to follow these instructions could result in death, serious injury, or equipment damage.
  • Page 10 Installation instructions│ R17│ Chapter 2: Safety Make sure that the user satisfies the age requirements in your country for operating the equipment. Make sure that the user is not under the influence of drugs, alcohol and medications. Make sure that the user knows and follows operating and maintenance instructions as well as all applicable safety procedures and requirements.
  • Page 11 Installation instructions│ R17│ Chapter 2: Safety Check the encapsulation, foils and cable for damages. If the encapsulation or foil is damaged, moisture can cause serious damage to the electronics. IM-PN-RX104-EN-v06...
  • Page 12: Chapter 3: Technical Data

    Installation instructions│ R17│ Chapter 3: Technical data CHAPTER 3: TECHNICAL DATA 3 . 1     R e c e i v e r s p e c i f i c a t i o n s Input power 7–32 V DC...
  • Page 13: Chapter 4: Product General Description

    Installation instructions│ R17│ Chapter 4: Product general description CHAPTER 4: PRODUCT GENERAL DESCRIPTION The pictures shown in this chapter are for illustrative purposes only. 4 . 1     R e c e i v e r d e s c r i p t i o n 1.
  • Page 14: Echanical Installation

    Installation instructions│ R17│ Chapter 4: Product general description 4 . 2     e c h a n i c a l i n s t a l l a t i o n NOTE: For mounting on a wall or equipment, use 4 M5x30 mm screws or equivalent fastening method.
  • Page 15 Installation instructions│ R17│ Chapter 4: Product general description 4 . 2 . 1     I N S T A L L A T I O N P R E C A U T I O N S RISK OF ELECTRIC SHOCK The receiver must only be opened by qualified installers or authorized personnel.
  • Page 16: Chapter 5: Board Description

    Installation instructions│ R17│ Chapter 5: Board description CHAPTER 5: BOARD DESCRIPTION NOTE: The pictures shown in this chapter are for illustrative purposes only. RISK OF ELECTRIC SHOCK The receiver must only be opened by qualified installers or authorized personnel. Make sure the power supply is switched off before opening the receiver.
  • Page 17 Installation instructions│ R17│ Chapter 5: Board description 1. Power LED (yellow) 10. Input power GND* 2. Function button (cancel) 11. Input power 12–24 V DC* 3. Select button (OK) 12. Status LED 1, for transistor output 1 4. Programming contact 13. Status LED 2, for transistor output 2 5.
  • Page 18 Installation instructions│ R17│ Chapter 5: Board description T e r m i n a l b l o c k f o r d i g i t a l i n p u t s o n t h e b a s e b o a r d – J 8 1.
  • Page 19: Chapter 6: Status And Error Indications

    Installation instructions│ R17│ Chapter 6: Status and error indications CHAPTER 6: STATUS AND ERROR INDICATIONS 6 . 1     F u n c t i o n L E D s i n d i c a t i o n i n n o r m a l o p e r a t i o n...
  • Page 20 Installation instructions│ R17│ Chapter 6: Status and error indications Color On Flashing Indicates yellow Receiving a radio packet from a transmitter ● set to a different radio mode green ● (discontinuous or continuous) than the receiver. yellow Receiving a radio packet from a transmitter ●...
  • Page 21: Status Leds Indications In Operation Mode

    Installation instructions│ R17│ Chapter 6: Status and error indications 6 . 2     S t a t u s L E D s i n d i c a t i o n s i n o p e r a t i o n m o d e There are four 2-color status LEDs (red/green) for status indication of the transistor outputs.
  • Page 22: Debug Mode Indications

    Installation instructions│ R17│ Chapter 6: Status and error indications 6 . 4     D e b u g m o d e i n d i c a t i o n s If the debug mode is activated, function LEDs will get new functions according to the following table: NOTE: Only use this setting for debug purpose.
  • Page 23: Error Indications And Code Messages

    Installation instructions│ R17│ Chapter 6: Status and error indications 6 . 5     E r r o r i n d i c a t i o n s a n d c o d e m e s s a g e s Errors are indicated by function LEDs 5–8, which...
  • Page 24: Chapter 7: Operation

    Installation instructions│ R17│ Chapter 7: Operation CHAPTER 7: OPERATION 7 . 1     G e n e r a l i n f o r m a t i o n To control a receiver, the transmitter must be registered and logged in to the receiver.
  • Page 25: Chapter 8: Configuration Menu

    Installation instructions│ R17│ Chapter 8: Configuration menu CHAPTER 8: CONFIGURATION MENU NOTE: The settings described in this chapter apply to R17 receiver with Software version SW0014-21v08 or higher. All configuration settings require access to the receiver circuit board(s). RISK OF ELECTRIC SHOCK The receiver must only be opened by qualified installers or authorized personnel.
  • Page 26: Register The Transmitter In The Receiver

    All function LEDs and status LEDs flash 1 time. The transmitter is registered. If no transmitter is found within approximately 10 seconds, the receiver exits to normal operation. Button 1 and 2 are factory defaults (see relevant Tele Radio AB transmitter installation instructions). IM-PN-RX104-EN-v06...
  • Page 27: Show Settings

    Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 3     S h o w s e t t i n g s 1. Press the receiver Function button three times. Function LED 7 lights (green). 2. Press the Select button.
  • Page 28: Operating Modes

    Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 4     O p e r a t i n g m o d e s This receiver is provided with three Operating modes as standard (1, 2 and 255). For other Operating modes, contact your representative for assistance.
  • Page 29 Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 4 . 2     O P E R A T I N G M O D E 1 NOTE: Only for continuous radio mode. Transistor output 1 High output signal when button 1 is pressed (otherwise high...
  • Page 30 Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 4 . 3     O P E R A T I N G M O D E 2 NOTE: Only for continuous radio mode. Transistor output 1 High output signal when button 1 is pressed (otherwise high...
  • Page 31 Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 4 . 4     O T H E R O P E R A T I N G M O D E S Contact your representative for assistance. O u t p u t p i n m o d e s Each output can be assigned one of the following modes.
  • Page 32: Active Load Select

    Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 5     A c t i v e L o a d s e l e c t NOTE: If this setting is set to 0 (status LEDs 1–4 are off), the receiver will always be activated when receiving a radio package.
  • Page 33 Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 5 . 2     C H A N G E L O A D S E L E C T 1. Press the Select button once. LED 1 flashes. Load A can be activated.
  • Page 34: Log A Transmitter Out

    Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 6     L o g a t r a n s m i t t e r o u t NOTE: Only for continuous radio mode. NOTE: The login/logout function cannot be activated/deactivated in the receiver.
  • Page 35: Erase All Registered Transmitters

    Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 7     E r a s e a l l r e g i s t e r e d t r a n s m i t t e r s NOTE: The following instructions will erase all registered transmitters from the receiver.
  • Page 36: Master Reset Of The Receiver

    Installation instructions│ R17│ Chapter 8: Configuration menu 8 . 8     M a s t e r r e s e t o f t h e r e c e i v e r This procedure will erase all settings from the receiver and restore factory defaults.
  • Page 37: Maintenance

    Tele Radio AB products are covered by a warranty against material, construction and manufacturing faults. During the warranty period, Tele Radio AB may replace the product or faulty parts. Work under warranty must be performed by Tele Radio AB or by an authorized service center specified by Tele Radio AB.
  • Page 38: Chapter 10: Regulatory Information

    For proper treatment, recovery and recycling, please take this product to a designated collection point. Tele Radio AB strives to minimize the use of hazardous materials, promotes reuse and recycling, and reduces emissions to air, soil and water. When a commercially viable alternative is available, Tele Radio AB strives to restrict or eliminate substances and materials that pose an environmental, health or safety risk.
  • Page 39 Installation instructions│ R17│ Annex A: Index ANNEX A: INDEX Active Load select Base board Boards CE marking code messages Configuration menu Enter menu mode Current consumption Debug mode indications Digital inputs on the base board 17-18 Erase all registered transmitters...
  • Page 40 Installation instructions│ R17│ Annex A: Index Logout Maintenance Master reset Menu mode Enter menu mode Menu mode indications Mounting dimensions Receiver Number of digital inputs Number of transistor outputs Operating modes Operating temperature Output pin modes Radio communication Radio mode...
  • Page 41 Installation instructions│ R17│ Annex A: Index Warnings & restrictions Installation and commission Maintenance Operation WEEE directive IM-PN-RX104-EN-v06...
  • Page 42 safe smart strong These Installation instructions are subject to change without prior notice. Download the latest Installation instructions from www.tele-radio.com .

This manual is also suitable for:

Pn-r17-1

Table of Contents