Using Guide of RFL-C015H1-CE 1 Safety Information Thank you for choosing Raycus fiber laser. This User Guide provides important safety, operation, warranty and other information. Please read it carefully before you use this product. In order to ensure safe operation and optimal performance of the product, please follow the warnings, cautions, operating procedures and other instructions accordingly.
Page 5
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Figure 1 Safety Label Locations These safety labels include warning labels, apertures through which laser radiation is emitted and labels of certification and identification, etc. Specifications of these labels are as follows:...
There are no operator serviceable parts inside, and all maintenance must be performed in Raycus or by qualified Raycus personnel. Do not try to remove covers, or electrical shock may be caused, and warranty will be void.
Check all items against the list and contact Raycus immediately if there is any missing item or evident damage to the unit. DO NOT attempt to install or operate the laser, if there is any evident or suspected damage to the unit.
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE CAUTION: The fiber optic cable and output head is precise optic instrument, any vibration or impact to the output head, and twist or excessive bend to the cable will damage the instrument.
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 2.6 Specifications Table 4 Specifications Items Conditions Indicator Value Unit Notes Optical Specifications Operation Modes CW/Modulated / Cooling water temperature Nominal Output Power 1200± 50 22±1℃ Power Adjust Range...
Inspect the output lens before installing the output head to the processing head. Clean the output lens if necessary. It is strictly prohibited to disassemble the output head by personnel not approved by Raycus, or the warranty is void. 3.3 Cooling Requirements Table 5 Cooling Requirements 型号...
Page 13
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 2) In order to prevent the growth of mold that may lead to pipe blockage, we recommend to add alcohol about 10% of the total volume. 3) If the product is used in an environment that ambient temperature is between -10℃ and 0℃, we recommend to use 30% alcohol, and replace it every two months.
Insert the water pipes into the inlet and outlet. e) Check the output head and clean it if necessary. This procedure must be performed by personnel of Raycus or authorized by Raycus. Make sure the environment is clean, or the output cable may be contaminated.
Page 15
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE CAUTION: The laser output optical cable should be kept as natural as possible and not be distorted. The too small bending radius of the output fiber cable will damage the laser.
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 4 Using the Product 4.1 Power Connection Table 6 Power Connection Requirements Model RFL-C015H1-CE Supply Source 40-80 V DC Power Cord The laser comes with a 1.5-meter power cord One End of Power Cord Three wires labeled +、-、PE...
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 4.4 Laser intelligent connection system APP operation instructions 4.4.1 Log in After opening the Laser intelligent connection system APP, the account and password login page are displayed, as shown in Figure 4: Figure 4 Log in interface 4.4.2 Connect...
Page 18
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Figure 5 Verification code login page Turn on the Bluetooth switch of the single-mode laser APP. If there is a Bluetooth device nearby, ensure that the Bluetooth is set Switch on the standby, click the "Search" button on the connection page.
Page 19
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Click "Connect" on the right of the searched Bluetooth device to enter the state of connection, as shown in Figure 7 sign: Figure 7 Connecting 4.4.3 Equipment After successful connection, the laser device-status interface is displayed, as shown in Figure 8:...
Page 20
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Figure 8 Device - Status The device status page mainly has the main power supply, equipment, alarm, light status display, and light. The state display of percentage, light output power, laser temperature, as well as the state display of emergency stop, REM, laser enable, red light, as well as the specific state of the laser and some parameter values.
Page 21
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Figure 9 /10 Device – Alarm (No alarm content & Specific title) The status display of the laser also has the function of supporting the setting of some parameters,...
Page 22
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Figure 11 Devices – Settings 4.4.4 Mine Entering Mine–About us, you can see function introduction, version update, and about machines, as shown in Figure 12:...
Page 23
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Figure 12 Mine – About us The APP version information interface displays the current version information and upgraded version of the laser. As shown in Figure 13: Figure 13 Mine - About us – App version...
Page 24
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Mine - About the machine page shows the relevant information of the laser, such as laser time, laser model, laser serial number, main control serial number, key version number, system information.
Page 25
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 4.4.5 Software introduction The Laser intelligent connection system APP is a mobile software that can be connected to the laser through Bluetooth to facilitate the after-sales, maintenance, and commissioning engineers, etc., without portable notebooks, you can use the single -mode laser app installed on Android phones to and the laser.
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 5 Instructions for use of switching power supply 5.1 Appearance structure and interface 5.1.1 Appearance structure Figure 17 The size of the switch power supply 5.1.2 Input/output interfaces The input and output of the switching power supply and the various signal ports are connected...
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE Table 8 The interface definition of the switching power supply Port Port Specifications Tag Number Function Description Name and Models Identification Protective Ground AC input neutral line AC Input BA8-03-13.0-00-C...
Page 28
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE The power module can be installed horizontally and sideways, and cannot be installed vertically (upright along the length of the module). The following is a reference installation diagram: Figure 19 Module Horizontal- Small Bracket Installation Reference Diagram (Unit: mm) Figure 20 Module Side Vertical- Small Bracket Installation Reference Diagram (Unit: mm) 5.2.2 Module heat dissipation requirements...
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE at the tail of the module. The temperature of the air outlet is about 10 ℃ higher than that of the air inlet, so the design of the module tail system avoids the installation of temperature- sensitive devices as much as possible.
Wuhan Raycus Fiber Laser Technologies Co., Ltd. Using Guide of RFL-C015H1-CE 6 Common alarm and handling measures 6.1 Alarms Display Connect Bluetooth, after the laser and the client software to establish normal communication. All alarm states of the laser can be displayed on the software interface, as shown in Figure 16.When the internal temperature of the laser is abnormal, Alarms are generated when the output power, scattered light, or power supply is abnormal.
Page 31
If there is no red guide light, please stop using the laser immediately and contact Raycus. If the red guide light output normally, please restart the laser to try, if the alarm continues to occur, please contact Raycus.
The warranties start on the date of shipment from Raycus for a period of time as set forth in the applicable purchase contracts or product specifications. Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period.
Page 33
All the items about warranty and service above provided by Raycus are for user’s reference; formal contents about warranty and service are subject to the contract.
Need help?
Do you have a question about the RFL-C015H1-CE and is the answer not in the manual?
Questions and answers