STACK100 User Manual
5 Storage
For long-term storage (more than 3 months), the battery cells should be stored within the
temperature range of 5 to 45
o
C, relative humidity <65% and non-corrosive gases.
The battery module should be stored within the temperature range of 5 to 45
o
C, dry, clean
and well ventilated environment. The battery should be charged to 50 - 55% SOC before
storage.
We recommend activating the battery system (discharge and charge) every 3 months, and
the longest duration of storage without charge and discharge should not exceed 6
months.
Corresponding to the battery system that has been installed and used normally, it is
necessary to regularly fully charge the battery to calibrate the SOC. It is recommended to
fully charge and calibrate at least once every 2 weeks.
CAUTION
The lifespan of the battery will be greatly reduced if you do not follow above instructions
to store the battery for a long term.
6 Shipment
The battery module is pre-charged to 50% SOC or according to customer requirements
before shipment. The remaining capacity of battery cells is determined by the storage
time and condition after shipment.
The battery modules meet UN38.3 certificate standard.
In particular, special rules for the carriage of goods on the road and the current dangerous
goods law, specifically ADR (European Convention on the International Carriage of
Dangerous Goods by Road), as amended, must be observed.
36
© Dyness reserves the copyright of this document.
Need help?
Do you have a question about the Stack100 and is the answer not in the manual?