VPX6200 BIOS
User's Manual
Manual Rev.:
Revision Date:
Part No.:
Rev. 1.0
April 30, 2024
50M-31428-2000

Advertisement

loading
Need help?

Need help?

Do you have a question about the VPX6200 BIOS and is the answer not in the manual?

Questions and answers

Summary of Contents for ADLINK Technology VPX6200 BIOS

  • Page 1 VPX6200 BIOS User’s Manual Manual Rev.: Rev. 1.0 Revision Date: April 30, 2024 Part No.: 50M-31428-2000...
  • Page 2: Preface

    VPX6200 BIOS Preface Copyright © 2024 ADLINK Technology, Inc. This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
  • Page 3: Table Of Contents

    VPX6200 BIOS Table of Contents Preface ..........................2 Table of Contents ........................3 1 BIOS Setup Menu ......................5 1.1 Introduction..........................5 1.2 Menu Selection Bar ........................ 5 1.3 Menu Conventions ........................5 2 Getting Started ......................... 6 2.1 BIOS Information ........................7 2.2 System Information .........................
  • Page 4 VPX6200 BIOS 4.2.6 Serial IO Configuration ........................60 4.2.7 PCH Thermal Throttling Control ..................... 61 5 Server Mgmt Menu ......................62 5.1 System Event Log ........................ 63 5.2 View FRU Information......................64 5.3 BMC Network Configuration ....................65 5.4 ADLINK IPMI Configuration ....................66 5.5 View System Event Log ......................
  • Page 5: Bios Setup Menu

    VPX6200 BIOS 1 BIOS Setup Menu Introduction The BIOS setup utility is invoked by pressing <ESC> or <DEL> keys. User can change BIOS settings during setup utility runs. A reset of system is required in order to make new settings take effect.
  • Page 6: Getting Started

    VPX6200 BIOS 2 Getting Started The Main Menu provides read-only information about system and also allows to set system’s date and time. Refer to the tables below, it shows the screen shot of Main menu for detail, and submenus and settings as well.
  • Page 7: Bios Information

    VPX6200 BIOS BIOS Information BIOS Item Options Description BIOS Vendor Info-only. Display vendor name of system BIOS. American Megatrends BIOS Version Info-only. Display version of booting BIOS. x.yy.zz Build Date Info-only. It shows the date that BIOS was built. MM/DD/YYYY SEMA Firmware Version Info-only.
  • Page 8: System Date/Time

    VPX6200 BIOS System Date/Time BIOS Item Options Description System Date MM/DD/YYYY For configuring/showing system date. When setting the Date, use <Tab> key to switch between Date elements. System Time HH:MM:SS For configuring/showing system time. When setting the Time, use <Tab> key to switch between Time elements.
  • Page 9 VPX6200 BIOS seconds the system is running in S0 state. This counter is cleared when the system is removed from the external power supply. Boot Cycles Info-only. The boot cycle is increased after a HW or SW reset or after a successful power- Boot Reason Info-only.
  • Page 10: Advanced Menu

    VPX6200 BIOS 3 Advanced Menu This menu contains the settings for most of the user interfaces in the system. Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit > CPU Configuration CPU Configuration > Power & Performance Parameters >...
  • Page 11: Cpu Configuration

    VPX6200 BIOS 3.1 CPU Configuration Aptio Setup – AMI Advanced CPU Configuration Type Intel(R) Xeon(R) W-11865MRE@2.60GHz Speed 2600 MHz 0x806D1 Stepping Number of Processors 8Core(s) / 8Thread(s) Microcode Revision GT Info 0x9A70 eDRAM Size L1 Instruction Cache 32 KB x 8...
  • Page 12: Power & Performance

    VPX6200 BIOS Intel Trusted Execution Enabled Enables utilization of additional hardware Disabled Technology capabilities provided by Intel (R) Trusted Execution Technology. Changes require a full power cycle to take effect. Power & Performance Aptio Setup – AMI Advanced >CPU – Power Management Control CPU –...
  • Page 13 VPX6200 BIOS > CPU VR Settings Platform PL1 Enable [Disabled] Platform PL2 Enable [Disabled] Power Limit 4 Override [Disabled] ^v: Select Item C states [Disabled] Enter: Select Thermal Monitor [Enabled] +/-: Change Opt. Interrupt Redirection Mode Selection [Fixed Priority] F1: General Help...
  • Page 14 VPX6200 BIOS BIOS Item Options Description HwP Fast MSR Support Enabled Enable/Disable HwP Fast MSR Support for Disabled IA32_HWP_REQUEST MSR. HDC Control Enabled This option allows HDC configuration. Disabled Config TDP Configurations Submenu CPU VR Settings Submenu Platform PL1 Enable...
  • Page 15 VPX6200 BIOS CTDP BIOS control Disabled ConfigTDP Levels ConfigTDP Turbo Activation Ratio 25 (Unlocked) Power Limit 1 25.0W (MSR:35.0) Power Limit 2 56.250W (MSR:56.250) Custom Settings Nominal ConfigTDP Nominal Ratio:26 TAR:25 PL1:45.0W ><: Select Screen Power Limit 1 25000 ^v: Select Item...
  • Page 16 VPX6200 BIOS BIOS Item Options Description Value must be between Max and Min Power Limits (specified by PACKAGE_POWER_SKU_MSR). Other SKUs: This value must be between Min Power Limit and TDP Power Limit 2 value in Milli Watts. BIOS will round to the nearest 1/8W when programming.
  • Page 17 VPX6200 BIOS CPU – Power Management Control  CPU VR Settings Aptio Setup – AMI Advanced CPU VR Settings PSYS Slope PSYS Offset PSYS Prefix PSYS PMax Power Min Voltage Override [Disabled] > Acoustic Noise Settings > VccIn VR Settings >...
  • Page 18 VPX6200 BIOS CPU – Power Management Control  CPU VR Settings Acoustic Noise Settings Aptio Setup – AMI Advanced Acoustic Noise Settings Acoustic Noise Mitigation [Disabled] Pre Wake Time Ramp Up Time Ramp Down Time VccIn VR Domain Disable Fast PKG C State Ramp for...
  • Page 19 VPX6200 BIOS BIOS Item Options Description Fast/16 number is 2, 4, 8, 16 to slow down the slew rate to help minimize acoustic noise CPU – Power Management Control CPU VR Settings VccIn VR Settings  Aptio Setup – AMI...
  • Page 20 VPX6200 BIOS BIOS Item Options Description AC Loadline defined in 1/100 mOhms. A value of 100 = 1.00 mOhm, and 1255 = AC Loadline 12.55 mOhm. Range is 0-6249 (0-62.49 mOhms). 0 = AUTO/HW default. Uses BIOS mailbox command 0x2.
  • Page 21 VPX6200 BIOS BIOS Item Options Description TDC Current Limit, defined in 1/8A increments. Range 0-32767. For a TDC TDC Current Limit Current Limit of 125A, enter 1000. 0 = 0 Amps. Uses BIOS VR mailbox command 0x1A. 1 ms, 2 ms, 3 ms, 4 TDC Time Window, value in milliseconds.
  • Page 22 VPX6200 BIOS CPU – Power Management Control  Custom P-state Table Aptio Setup – AMI Advanced Custom P-state Table Number of P states ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 23: Gt - Power Management Control

    VPX6200 BIOS CPU – Power Management Control  CPU Lock Configuration Aptio Setup – AMI Advanced CFG Lock [Enabled] Overclocking Lock [Enabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 24: Power Management

    VPX6200 BIOS BIOS Item Options Description RC6(Render Standby) Enabled Check to enable render standby support. Disabled Default Max Frequency, 100Mhz, 150Mhz, 200Mhz, 250Mhz, 300Mhz, 350Mhz, 400Mhz, Maximum GT frequency limited by the 450Mhz, 500Mhz, user. Choose between 350MHz (RPN) and...
  • Page 25: Voltage Monitor

    VPX6200 BIOS 3.3.1 Voltage Monitor Aptio Setup – AMI Advanced Voltage Monitor XXX V 5VSB XXX V XXX V 3.3V XXX V VMEM XXX V 3.3VSB XXX V XXX V VCORE ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 26: System Management

    VPX6200 BIOS 3.4 System Management Aptio Setup – AMI Advanced System Management SEMA Firmware Version ADLINK > SEMA Flags SEMA Features: System Restart Event 4096 Bytes User-Flash Runtime Watchdog Temperatures Voltage Monitor Power-up Watchdog Boot Counter ><: Select Screen Dual-BIOS...
  • Page 27: Sema Flags

    VPX6200 BIOS 3.4.1 SEMA Flags Aptio Setup – AMI Advanced SEMA Flags SEMA Flags 0x00 BMC Select Standard BIOS ATX/AT-Mode AT Mode ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 28: Thermal Management

    VPX6200 BIOS 3.5 Thermal Management Aptio Setup – AMI Advanced Thermal Management > CPU Thermal Configuration > Platform Thermal Configuration > Temperatures ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 29: Cpu Thermal Configuration

    VPX6200 BIOS 3.5.1 CPU Thermal Configuration Aptio Setup – AMI Advanced Cpu Thermal Configuration DTS SMM [Enabled] Tcc Activation Offset Tcc Offset Time Window [Disabled] Tcc Offset Clamp Enable [Disabled] Tcc Offset Lock Enable [Enabled] Bi-directional PROCHOT# [Enabled] Disable PROCHOT# Output...
  • Page 30: Platform Thermal Configuration

    VPX6200 BIOS Enabled Tcc Offset Clamp bit Enable for Running Disabled Tcc Offset Clamp Enable Average Temperature Limit(RATL) feature to allow CPU to throttle below P1. Enabled Lock Enable for Running Average Tcc Offset Lock Enable Disabled Temperature Limit(RATL) feature to lock Temperature Target MSR.
  • Page 31 VPX6200 BIOS BIOS Item Options Description Disabled, 80 C, 90 C, This value controls the temperature of the Critical Trip Point 95 C, 100 C ACPI Critical Trip Point - the point in which the OS will shut the system off.
  • Page 32 VPX6200 BIOS Disabled, 15 C, 23 C, This value controls the temperature of the 31 C, 39 C, 47 C, 55 C, ACPI Passive Trip Point - the point in which Passive Trip Point 63 C, 71 C, 79 C, 87 C, the OS will begin throttling the processor.
  • Page 33: Temperatures

    VPX6200 BIOS 3.5.3 Temperatures Aptio Setup – AMI Advanced Temperatures and Fan Speed CPU Temperature Current xx C Startup xx C xx C xx C At the Front Edge Temperatures Current xx C Startup xx C xx C xx C ><: Select Screen...
  • Page 34: Watchdog Timer

    VPX6200 BIOS 3.6 Watchdog Timer Aptio Setup – AMI Advanced Watchdog Timer Power-Up Watchdog [Disabled] ATTENTION: Pressing F12 during start up disables the Power Up Watchdog. RunTime Watchdog [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 35: Super Io Configuration

    VPX6200 BIOS 3.7 Super IO Configuration Aptio Setup – AMI Advanced Super IO Configuration > NCT5104DSEC Super IO Configuration ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save & Exit...
  • Page 36 VPX6200 BIOS NCT5104DSEC Super IO Configuration  Serial Port x Configuration Aptio Setup – AMI. Advanced Serial Port x Configuration Serial Port [Enabled] Device Settings IO=240; IRQ=4; Change Settings [Auto] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 37: Vpx Configuration

    VPX6200 BIOS 3.8 VPX Configuration Aptio Setup – AMI Advanced VPX Configuration Watchdog ACPI Event Shutdown [Disabled] COM1 port mode [RS232] COM2 port mode [RS232] CPU TDP Power Limit 1 Config [25W] PCIe Scan Delay EC GPIO Options GPIO Pin Direction...
  • Page 38 VPX6200 BIOS Input Mode Indicates whether the GPIO Pin is Output Mode interrupted. Write 0x00 to clear the GPIO Pin Direction interrupt and EC_GPIO_INT will be changed to high level No interrupt, Interrupt both When GPIO Pin is input mode, it supports...
  • Page 39: Usb Configuration

    VPX6200 BIOS 3.9 USB Configuration Aptio Setup – AMI Advanced USB Configuration USB Module Version USB Controllers: 1 XHCI USB Devices: 1 Drive, 1 Keyboard, 1 Mouse, 1 Hub Legacy USB Support [Enabled] XHCI Hand-off [Enabled] USB Mass Storage Driver Support...
  • Page 40: Ami Graphic Output Protocol Policy

    VPX6200 BIOS BIOS Item Options Description Auto, Manual Maximum time the device will take before it properly reports itself to the Host Device power-up delay Controller. 'Auto' uses default value: for a Root port it is 100 ms, for a Hub port the delay is taken from Hub descriptor.
  • Page 41: Serial Port Console Redirection

    VPX6200 BIOS 3.11 Serial Port Console Redirection Aptio Setup – AMI Advanced COM0 Console Redirection [Disabled] > Console Redirection Settings COM1 Console Redirection [Disabled] > Console Redirection Settings COM2 Console Redirection [Disabled] > Console Redirection Settings Serial Port for Out-of-Band Management/...
  • Page 42: Network Stack Configuration

    VPX6200 BIOS 3.12 Network Stack Configuration Aptio Setup – AMI Advanced Network Stack [Disabled] IPv4 PXE Support [Disabled] IPv4 HTTP Support [Disabled] IPv6 PXE Support [Disabled] IPv6 HTTP Support [Disabled] PXE boot wait time Media detect count ><: Select Screen...
  • Page 43: Trusted Computing

    VPX6200 BIOS 3.13 Trusted Computing Aptio Setup – AMI Advanced TPM 2.0 Device Found Firmware Version: 7.85 Vendor: Security Device Support [Enabled] Active PCR banks SHA256 Available PCR banks SHA256 SHA256 PCR Bank [Enabled] Pending operation [None] [Enabled] Platform Hierarchy...
  • Page 44 VPX6200 BIOS BIOS Item Options Description Version Version 1.2 or 1.3. Note some HCK tests might not support 1.3. Select the Communication Interface to TPM 2.0 InterfaceType TPM 20 Device. TPM 1.2 TPM 1.2 will restrict support to TPM 1.2 TPM 2.0...
  • Page 45: Chipset Menu

    VPX6200 BIOS 4 Chipset Menu This menu contains the settings for most of the chipset I/O in the system. Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit > System Agent (SA) Configuration > PCH-IO Configuration ><: Select Screen...
  • Page 46: System Agent (Sa) Configuration

    VPX6200 BIOS 4.1 System Agent (SA) Configuration Aptio Setup – AMI Chipset System Agent (SA) Configuration VT-d Supported > Memory Configuration > Graphics Configuration > PEG Port Feature Configuration > VMD setup menu Stop Grant Configuration [Auto] VT-d [Enabled] [Disabled]...
  • Page 47: Memory Configuration

    VPX6200 BIOS 4.1.1 Memory Configuration Aptio Setup – AMI Chipset Memory Configuration Memory RC Version 2.0.2.9 Memory Speed 3200 MT/s Memory Timings (tCL-tRCD-tRP-tRAS) 22-22-22-52 Controller 0 Channel 0 Slot 0 Populated & Enabled Size 16384 MB (DDR4) Number of Ranks...
  • Page 48: Peg Port Feature Configuration

    VPX6200 BIOS 4.1.2 PEG Port Feature Configuration Aptio Setup – AMI Chipset PEG Port Feature Configuration Detect Non-Compliance Device [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 49: Pci Express Configuration

    VPX6200 BIOS ESC: Exit BIOS Item Options Description Disabled Enable/Disable to VMD controller Enable VMD controller Enabled Enabled VMD Global Disabled Enable/Disable to VMD Global Mapping Mapping Enabled Map this Root Port under Disabled Enable/Disable to Map this Root Port...
  • Page 50 VPX6200 BIOS Enabled for each root port. PCI Express Power Gating Disabled PCI Express Power Gating Enable/Disable Enabled for each root port. PCIe function swap Disabled When Disabled, prevents PCIE rootport Enabled function swap. If any function other than 0th is enabled, 0th will become visible.
  • Page 51 VPX6200 BIOS LTR Lock [Disabled] ^v: Select Item Enter: Select CPU PCIe Gen3 HWEQ Config +/-: Change Opt. UPTP F1: General Help DPTP F8: Previous Values F9: Optimized Default CPU PCIe Gen4 HWEQ Config F10: Save & Exit UPTP ESC: Exit...
  • Page 52: Pch-Io Configuration

    VPX6200 BIOS Error Enable/Disable. PME SCI Disabled, Enabled PCI Express PME SCI Enable/Disable. Hot Plug Disabled, Enabled PCI Express Hot Plug Enable/Disable. Advanced Error Reporting Disabled, Enabled Advanced Error Reporting Enable/Disable. Auto, Gen1, Gen2, PCIe Speed Configure PCIe Speed Gen3, Gen4...
  • Page 53 VPX6200 BIOS BIOS Item Options Description > SATA And RST Submenu Configuration > USB Configuration Submenu Submenu > Security Configuration > HD Audio Configuration Submenu Submenu > SerialIo Configuration > Pch Thermal Throttling Submenu Control > TSN GBE Configuration Submenu...
  • Page 54: Sata And Rst Configuration

    VPX6200 BIOS Disabled Enable/Disable TCO timer. When disabled, Enabled it disables PCH ACPI timer, stops TCO Enable TCO Timer timer, and ACPI WDAT table will not be published. Disabled Enable/Disable Timed GPIO0. When Enabled disabled, it disables cross time stamp...
  • Page 55 VPX6200 BIOS BIOS Item Options Description Disabled SATA Controller(s) Enable/Disable SATA Device. Enabled AHCI Intel RST Premium Determines how SATA controller(s) SATA Mode Selection With Intel Optane operate. System Acceleration Disabled Test Mode Enable/Disable (Loop Back). SATA Test Mode Enabled Submenu >...
  • Page 56: Software Feature Mask Configuration

    VPX6200 BIOS 4.2.2 Software Feature Mask Configuration Aptio Setup – AMI Chipset Software Feature Mask Configuration HDD Unlock [Enabled] LED Locate [Enabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 57: Usb Configuration

    VPX6200 BIOS 4.2.3 USB Configuration Aptio Setup – AMI Chipset USB Configuration xDCI Support [Disabled] USB2 PHY Sus Well Power Gating [Enabled] USB3 Link Speed Selection [GEN1] USB PDO Programming [Enabled] XHCI LTR Mode [Enabled] USB Overcurrent [Enabled] USB Overcurrent Lock [Enabled] ><: Select Screen...
  • Page 58: Security Configuration

    VPX6200 BIOS 4.2.4 Security Configuration Aptio Setup – AMI Chipset Security Configuration RTC Memory Lock [Enabled] BIOS Lock [Disabled] Force unlock on all GPIO pads [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help...
  • Page 59: Hd Audio Configuration

    VPX6200 BIOS 4.2.5 HD Audio Configuration Aptio Setup – AMI Chipset HD Audio Subsystem Configuration Settings HD Audio [Enabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save & Exit...
  • Page 60: Serial Io Configuration

    VPX6200 BIOS 4.2.6 Serial IO Configuration Aptio Setup – AMI Chipset SerialIo Configuration UART0 Controller [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save & Exit...
  • Page 61: Pch Thermal Throttling Control

    VPX6200 BIOS 4.2.7 PCH Thermal Throttling Control Aptio Setup – AMI Chipset Thermal Throttling Level [Suggested Setting] DMI Thermal Setting [Suggested Setting] SATA Thermal Setting [Suggested Setting] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help...
  • Page 62: Server Mgmt Menu

    VPX6200 BIOS 5 Server Mgmt Menu This menu contains the settings for IPMI BMC in the system. Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit BMC Self Test Status PASSED BMC Device ID BMC Device Revision BMC Firmware Revision 0.04...
  • Page 63: System Event Log

    VPX6200 BIOS 5.1 System Event Log Aptio Setup – AMI Server Mgmt Enabling/Disabling Options SEL Components [Enabled] Erasing Settings Erase SEL [No] When SEL is Full [Do Nothing] Custom EFI Logging Options Log EFI Status Codes [Error code] NOTE: All values changed here do not take effect until computer is restarted.
  • Page 64: View Fru Information

    VPX6200 BIOS 5.2 View FRU Information Aptio Setup – AMI Server Mgmt FRU information Board Manufacturer ADLINK Board Product VPX6200 Board Serial Number PPS0000001 Board Part Number 55-31129 Product Manufacturer ADLINK Product Name VPX6200 Product Part Number 91-31129 Product Version...
  • Page 65: Bmc Network Configuration

    VPX6200 BIOS 5.3 BMC Network Configuration Aptio Setup – AMI Server Mgmt --BMC network configuration-- ********************** Configure IPv4 support ********************** LAN channel 1 Configuration Address source [Unspecified] Current Configuration Address StaticAddress source Station IP address xxx.xxx.xxx.xxx Subnet mask xxx.xxx.xxx.xxx Station MAC address...
  • Page 66: Adlink Ipmi Configuration

    VPX6200 BIOS 5.4 ADLINK IPMI Configuration Aptio Setup – AMI Server Mgmt PCB Version Geographical Address 0x1E System Controller Host NVMRO Signal Non Protect NVMRO item Control [Non-Protect] SYS_RESET Support [Enabled] GA Status It’s GA 17 SBC Control Status 3x SBC (GA17/18/19)
  • Page 67: View System Event Log

    VPX6200 BIOS 5.5 View System Event Log Aptio Setup – AMI Server Mgmt No. of log entries in SEL : xxx DATE TIME SENSOR TYPE ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 68: Security Menu

    VPX6200 BIOS 6 Security Menu This menu contains the settings for security in the system. Aptio Setup – AMI Main Advanced Chipset Boot Security Save & Exit Password Description If ONLY the Administrator’s password is set, then this only limits access to Setup and is Only asked for when entering Setup.
  • Page 69 VPX6200 BIOS BIOS Item Options Description Secure Boot menu Submenu When selecting a HDD to configure passwords, BIOS will enter another new BIOS setup page like below. The method of configuring HDD password is the same as BIOS passwords. Once password is set, it will reflect the status on the screen, like ‘INSTALLED’ change on ‘HDD User Pwd Status’.
  • Page 70: Secure Boot

    VPX6200 BIOS 6.1 Secure Boot Aptio Setup – AMI Security System Mode User Secure Boot [Disabled] Not Active Secure Boot Mode [Standard] > Restore Factory Keys > Reset To Setup Mode ><: Select Screen > Key Management ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 71: Boot Menu

    VPX6200 BIOS 7 Boot Menu This menu contains the settings for bootable devices in the system. Aptio Setup – AMI. Main Advanced Chipset Server Mgmt Security Boot Save & Exit Boot Configuration Setup Prompt Timeout Bootup NumLock State [On] Quiet Boot...
  • Page 72 VPX6200 BIOS Boot Option #1~#11 Hard Disk Set system boot order. NVME CD/DVD USB Hard Disk USB CD/DVD USB Key USB Floppy USB Lan Network Disabled...
  • Page 73: Save & Exit

    VPX6200 BIOS 8 Save & Exit Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit Save Options Exit system setup after Save Changes and Exit saving the changes. Discard Changes and Exit Save Changes and Reset...
  • Page 74: Important Safety Instructions

    VPX6200 BIOS Important Safety Instructions For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment. 1. Read these safety instructions carefully. 2. Keep this user’s manual for future reference.
  • Page 75 VPX6200 BIOS 8. This equipment is not suitable for use in locations where children are likely to be present. 9. Equipment must be serviced by authorized technicians when: The power cord or plug is damaged; • Liquid has penetrated the equipment;...
  • Page 76: Getting Service

    6450 Via Del Oro, San Jose, CA 95119-1208, USA Tel: +1-408-360-0200 Toll Free: +1-800-966-5200 (USA only) Fax: +1-408-600-1189 Email: info@adlinktech.com ADLINK Technology (China) Co., Ltd. Address: 上海市浦东新区张江高科技园区芳春路 300 号 (201203) 300 Fang Chun Rd., Zhangjiang Hi-Tech Park, Pudong New Area Shanghai, 201203 China Tel: +86-21-5132-8988 Fax: +86-21-5132-3588 Email: market@adlinktech.com...