ADLINK Technology VPX3-TL BIOS User Manual
Hide thumbs Also See for VPX3-TL BIOS:

Advertisement

Quick Links

VPX3-TL BIOS
User's Manual
Manual Rev.:
Revision Date:
Part No.:
Rev. 1.0
July 5, 2023
50M-31129-2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VPX3-TL BIOS and is the answer not in the manual?

Questions and answers

Summary of Contents for ADLINK Technology VPX3-TL BIOS

  • Page 1 VPX3-TL BIOS User’s Manual Manual Rev.: Rev. 1.0 Revision Date: July 5, 2023 Part No.: 50M-31129-2000...
  • Page 2: Preface

    VPX3-TL BIOS Preface Copyright © 2023 ADLINK Technology, Inc. This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
  • Page 3: Table Of Contents

    VPX3-TL BIOS Table of Contents Preface ..........................2 Table of Contents........................3 1 BIOS Setup Menu ......................5 Introduction ..........................5 Menu Selection Bar........................5 Menu Conventions ........................5 2 Getting Started......................... 6 BIOS Information ........................6 System Information ........................7 System Date/Time........................
  • Page 4 VPX3-TL BIOS 4.2.3 USB Configuration ...........................62 4.2.4 Security Configuration ........................63 4.2.5 HD Audio Configuration ........................64 4.2.6 Serial IO Configuration ........................65 4.2.7 PCH Thermal Throttling Control ......................66 5 Server Mgmt Menu ......................67 System Event Log........................68 View FRU information ......................69 BMC network configuration....................
  • Page 5: Bios Setup Menu

    VPX3-TL BIOS 1 BIOS Setup Menu Introduction The BIOS setup utility is invoked by pressing <ESC> or <DEL> keys. User can change BIOS settings during setup utility runs. A reset of system is required in order to make new settings take effect.
  • Page 6: Getting Started

    VPX3-TL BIOS 2 Getting Started The Main Menu provides read-only information about system and also allows to set system’s date and time. Refer to the tables below, it shows the screen shot of Main menu for detail, and submenus and settings as well.
  • Page 7: System Information

    VPX3-TL BIOS BIOS Item Options Description VBIOS Version / GOP Info-only. VBIOS Version: When video option ROM Version yyyy/x.y.zzzz is set to “Legacy Only”, it will show up. GOP Version: When video option ROM is set to “UEFI Only”, it will show up.
  • Page 8: Board Information

    VPX3-TL BIOS Board Information Aptio Setup – AMI Main Board Information Serial Number Manufacturing Date Last Repair Date MAC ID Runtime Statistics Total Runtime 12h 51m Current Runtime 0h 01m 29s Power Cycles Boot Cycles Boot Reason Software-reset ><: Select Screen...
  • Page 9: Advanced Menu

    VPX3-TL BIOS 3 Advanced Menu This menu contains the settings for most of the user interfaces in the system. Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit > CPU Configuration CPU Configuration > Power & Performance Parameters >...
  • Page 10: Cpu Configuration

    VPX3-TL BIOS AMI Graphic Output Protocol Submenu User Select Monitor Output by Graphic Policy Output Protocol Serial Port Console Submenu Redirection Network Stack Configuration Submenu Trusted Computing Submenu TLS Auth Configuration Submenu RAM Disk Configuration Submenu Intel(R) Ethernet Network Submenu...
  • Page 11: Power & Performance

    VPX3-TL BIOS Number of Processors Info-only. It shows what detail CPU information Microcode Revision Info-only. It shows what detail CPU information GT Info Info-only. It shows what detail CPU information eDRAM Size Info-only. It shows what detail CPU information L1 Instruction Cache Info-only.
  • Page 12: Cpu - Power Management Control

    VPX3-TL BIOS 3.2.1 CPU – Power Management Control Aptio Setup – AMI Advanced CPU – Power Management Control CPU – Power Management Control Options Boot performance mode [Turbo Performance] Intel(R) SpeedStep(tm) [Enabled] Race To Halt (RTH) [Enabled] Intel(R) Speed Shift Technology...
  • Page 13 VPX3-TL BIOS BIOS Item Options Description MSR 1FC bit 20) Intel(R) Speed Shift Enabled Enable/Disable Intel(R) Speed Shift Technology Disabled Technology support. Enabling will expose the CPPC v2 interface to allow for hardware controlled P-states. Per Core P State OS...
  • Page 14 VPX3-TL BIOS BIOS Item Options Description Platform PL1 Power 50000 Platform Power Limit 1 Power in Milli Watts. BIOS will round to the nearest 1/8W when programming. Any value can be programmed between Max and Min Power Limits (specified by PACKAGE_POWER_SKU_MSR).
  • Page 15 VPX3-TL BIOS BIOS Item Options Description Power Limit 3 Settings Submenu CPU Lock Configuration Submenu CPU – Power Management Control View/Configure Turbo Options Aptio Setup – AMI Advanced Current Turbo Settings Max Turbo Power Limit 4095.875 Min Turbo Power Limit Package TDP Limit 45.0...
  • Page 16 VPX3-TL BIOS 5-core Turbo Ratio Limit Info-only. Ratio (TRLR) 6-core Turbo Ratio Limit Info-only. Ratio (TRLR) Enabled Energy Efficient P-state Disabled Package Power Limit MSR Enabled Lock Disabled Energy Efficient Turbo Enabled Disabled CPU – Power Management Control Config TDP Configurations Aptio Setup –...
  • Page 17 VPX3-TL BIOS BIOS Item Options Description Enabled Configurable TDP Mode Lock sets the Lock Disabled bits on TURBO_ACTIVATION_RATIO and CONFIG_TDP_CONTROL. Note: Configurable TDP Lock When CTDP Lock is enabled Custom ConfigTDP Count will be forced to 1 and Custom ConfigTDP Boot Index will be forced to 0.
  • Page 18 VPX3-TL BIOS BIOS Item Options Description Power Limit 2 value in Milli Watts. BIOS will round to the nearest 1/8W when programming. 0 = no custom override. For Power Limit 2 12.50W, enter 12500. Processor applies control policies such that the package power does not exceed this limit.
  • Page 19 VPX3-TL BIOS BIOS Item Options Description PSYS Slope defined in 1/100 increments. Range is 0-200. For a 1.25 slope, enter PSYS Slope 125. 0 = AUTO. Uses BIOS VR mailbox command 0x9." PSYS Offset defined in 1/1000 increments. Range is 0-63999. For an offset of 25.348, PSYS Offset enter 25348.
  • Page 20 VPX3-TL BIOS BIOS Item Options Description Enabled Enabling this option will help mitigate Acoustic Noise Mitigation Disabled acoustic noise on certain SKUs when the CPU is in deeper C state Set the maximum Pre Wake randomization time in micro ticks. Range Pre Wake Time is 0-255.
  • Page 21 VPX3-TL BIOS CPU – Power Management Control CPU VR Settings VccIn VR Settings Aptio Setup – AMI Advanced VccIn VR Domain VR Config Enable [Enabled] Current AC Loadline Current DC Loadline Current Psi1 Threshold Current Psi2 Threshold Current Psi3 Threshold...
  • Page 22 VPX3-TL BIOS BIOS Item Options Description DC Loadline defined in 1/100 mOhms. A value of 100 = 1.00 mOhm, and 1255 = DC Loadline 12.55 mOhm. Range is 0-6249 (0-62.49 mOhms). 0 = AUTO/HW default. Uses BIOS mailbox command 0x2.
  • Page 23 VPX3-TL BIOS BIOS Item Options Description ms, 5 ms, 6 ms, 7 ms, 1ms is default. Range from 1ms to 10ms, 8 ms, 10 ms except for 9ms. 9ms has no valid encoding in the MSR definition. Enabled TDC Lock...
  • Page 24 VPX3-TL BIOS CPU – Power Management Control Custom P-state Table Aptio Setup – AMI Advanced Custom P-state Table Number of P states ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 25 VPX3-TL BIOS CPU – Power Management Control Power Limit 3 Settings Aptio Setup – AMI Advanced Power Limit 3 Override [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 26: Gt - Power Management Control

    VPX3-TL BIOS 3.2.2 GT – Power Management Control Aptio Setup – AMI Advanced GT – Power Management Control RC6(Render Standby) [Enabled] Maximum GT frequency [Default Max Frequency] Disable Turbo GT frequency [Enabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 27: Intel(R) Time Coordinated Computing

    VPX3-TL BIOS 3.3 Intel(R) Time Coordinated Computing Aptio Setup – AMI Advanced Intel(R) Time Coordinated Computing (Intel(R) TCC) #AC Split Lock [Disabled] IFU Enable [Disabled] Intel(R) TCC Mode [Disabled] Intel(R) TCC Mode Affected Settings IO Fabric Low Latency [Disabled] GT CLOS...
  • Page 28 VPX3-TL BIOS BIOS Item Options Description Enabled Enable or Disable Graphics Disabled Technology(GT) Class of Service. Enable GT CLOS will reduce Gfx LLC allocation to minimize impact of Gfx workload on LLC Enabled Enable or Disable Opio Recentering to OPIO Recentering Disabled improve Pcie latency.
  • Page 29: Power Management

    VPX3-TL BIOS 3.4 Power Management Aptio Setup – AMI Advanced Power Management Enable ACPI Auto Configuration [Disabled] Power-Up Mode [Turn On] ATTENTION: The Power-Up Mode only has effect, if the module is in ATX-Mode. > Power Consumption ><: Select Screen...
  • Page 30: Power Consumption

    VPX3-TL BIOS 3.4.1 Power Consumption Aptio Setup – AMI Advanced Power Consumption Main Current XXX A Current Input Power XXX W XXX V 5VSB XXX V XXX V 3.3V XXX V VMEM XXX V 3.3VSB XXX V VCORE XXX V ><: Select Screen...
  • Page 31: System Management

    VPX3-TL BIOS 3.5 System Management Aptio Setup – AMI Advanced System Management SEMA Firmware Version ADLINK > SEMA Flags SEMA Features: Uptime & Power Cycles Counter System Restart Event 4096 Bytes User-Flash Runtime Watchdog Temperatures Voltage Monitor Power-up Watchdog Boot Counter ><: Select Screen...
  • Page 32: Sema Flags

    VPX3-TL BIOS 3.5.1 SEMA Flags Aptio Setup – AMI Advanced SEMA Flags SEMA Flags 0x00 BMC Select Standard BIOS ATX/AT-Mode AT Mode ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 33: Thermal Management

    VPX3-TL BIOS 3.6 Thermal Management Aptio Setup – AMI Advanced Thermal Management > CPU Thermal Configuration > Platform Thermal Configuration > Temperatures ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 34: Cpu Thermal Configuration

    VPX3-TL BIOS 3.6.1 CPU Thermal Configuration Aptio Setup – AMI Advanced Cpu Thermal Configuration DTS SMM [Enabled] Tcc Activation Offset Tcc Offset Time Window [Disabled] Tcc Offset Clamp Enable [Disabled] Tcc Offset Lock Enable [Enabled] Bi-directional PROCHOT# [Enabled] Disable PROCHOT# Output...
  • Page 35: Platform Thermal Configuration

    VPX3-TL BIOS Enabled Tcc Offset Clamp bit Enable for Running Tcc Offset Clamp Enable Disabled Average Temperature Limit(RATL) feature to allow CPU to throttle below P1. Enabled Lock Enable for Running Average Tcc Offset Lock Enable Disabled Temperature Limit(RATL) feature to lock Temperature Target MSR.
  • Page 36 VPX3-TL BIOS BIOS Item Options Description Disabled, 80 C, 90 C, This value controls the temperature of the Critical Trip Point 95 C, 100 C ACPI Critical Trip Point - the point in which the OS will shut the system off.
  • Page 37: Temperatures

    VPX3-TL BIOS 3.6.3 Temperatures Aptio Setup – AMI Advanced Temperatures and Fan Speed CPU Temperature Current 100 C Startup 50 C 26 C 100 C Board Temperatures Current 48 C Startup 28 C 17 C 60 C ><: Select Screen...
  • Page 38: Watchdog Timer

    VPX3-TL BIOS 3.7 Watchdog Timer Aptio Setup – AMI Advanced Watchdog Timer Power-Up Watchdog [Disabled] ATTENTION: Pressing F12 during start up disables the Power Up Watchdog. RunTime Watchdog [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 39: Super Io Configuration

    VPX3-TL BIOS 3.8 Super IO Configuration Aptio Setup – AMI Advanced Super IO Configuration > NCT5104DSEC Super IO Configuration ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save & Exit...
  • Page 40 VPX3-TL BIOS BIOS Item Options Description Super IO Chip Info-only Serial Port x Configuration Submenu NCT5104DSEC Super IO Configuration Serial Port x Configuration Aptio Setup – AMI. Advanced Serial Port x Configuration Serial Port [Enabled] Device Settings IO=3F8h; IRQ=4; Change Settings [Auto] ><: Select Screen...
  • Page 41: Vpx Configuration

    VPX3-TL BIOS 3.9 VPX Configuration Aptio Setup – AMI Advanced VPX Configuration WOL From S5 [ON] Active Cooling Trip Point [Refer to BMC] Passive Cooling Trip Point [Disabled] Critical Trip Point [Disabled] Watchdog ACPI Event Shutdown [Disabled] PCIE_BFR_SEL [1x8 + 2x4]...
  • Page 42 VPX3-TL BIOS BIOS Item Options Description Interrupt trigger Indicates whether the GPIO Pin is No Interrupt interrupted. Write 0x00 to clear the EC_GPI0 interrupt and EC_GPIO_INT will be changed to high level Interrupt trigger Indicates whether the GPIO Pin is No Interrupt interrupted.
  • Page 43: Usb Configuration

    VPX3-TL BIOS 3.10 USB Configuration Aptio Setup – AMI Advanced USB Configuration USB Module Version USB Controllers: 1 XHCI USB Devices: 1 Drive, 1 Keyboard, 1 Mouse, 1 Hub Legacy USB Support [Enabled] XHCI Hand-off [Enabled] USB Mass Storage Driver Support...
  • Page 44: Ami Graphic Output Protocol Policy

    VPX3-TL BIOS BIOS Item Options Description Auto, Manual Maximum time the device will take before it properly reports itself to the Host Device power-up delay Controller. 'Auto' uses default value: for a Root port it is 100 ms, for a Hub port the delay is taken from Hub descriptor.
  • Page 45: Serial Port Console Redirection

    VPX3-TL BIOS 3.12 Serial Port Console Redirection Aptio Setup – AMI Advanced COM2 Console Redirection > Console Redirection Settings COM3 Console Redirection > Console Redirection Settings Serial Port Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection EMS > Console Redirection Settings ><: Select Screen...
  • Page 46: Console Redirection Settings

    VPX3-TL BIOS 3.12.1 Console Redirection Settings Aptio Setup – AMI Advanced COMx Emulation: ANSI: Console Redirection Settings Extended ASCII char set. VT100: ASCII char Terminal Type [ANSI] set. VT100+: Extends Bits per second [115200] VT100 to support color, Data Bits function keys, etc.
  • Page 47 VPX3-TL BIOS None, Even, Odd, Mark, Parity Configures if parity bit is generated Space (transmit data) or checked. A parity bit can be sent with the data bits to detect some transmission errors. Even: parity bit is 0 if the num of 1's in the data bits is even.
  • Page 48: Console Redirection Settings (Ems)

    VPX3-TL BIOS 3.12.2 Console Redirection Settings (EMS) Aptio Setup – AMI Advanced Out-of-Band Mgmt Port [COM0] Terminal Type EMS [VT-UTF8] Bits per second EMS [115200] Flow Control EMS [None] Data Bits EMS Parity EMS None Stop Bits EMS ><: Select Screen...
  • Page 49: Network Stack Configuration

    VPX3-TL BIOS BIOS Item Options Description Info-only Data Bits EMS Parity EMS Info-only Info-only Stop Bits EMS 3.13 Network Stack Configuration Aptio Setup – AMI Advanced Network Stack [Disabled] IPv4 PXE Support [Disabled] IPv4 HTTP Support [Disabled] IPv6 PXE Support...
  • Page 50: Trusted Computing

    VPX3-TL BIOS BIOS Item Options Description Wait time in seconds to press ESC key to PXE boot wait time abort the PXE boot. Use either +/- or numeric keys to set the value. Number of times the presence of media Media detect count will be checked.
  • Page 51 VPX3-TL BIOS BIOS Item Options Description SHA256 PCR Bank Disable Enable or Disable SHA256 PCR Bank Enable None Schedule an Operation for the Security TPM Clear Device. NOTE: Your Computer will reboot Pending operation during restart in order to change State of Security Device.
  • Page 52: Chipset Menu

    VPX3-TL BIOS 4 Chipset Menu This menu contains the settings for most of the chipset I/O in the system. Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit > System Agent (SA) Configuration > PCH-IO Configuration ><: Select Screen...
  • Page 53: System Agent (Sa) Configuration

    VPX3-TL BIOS 4.1 System Agent (SA) Configuration Aptio Setup – AMI Chipset System Agent (SA) Configuration VT-d Supported > Memory Configuration > Graphics Configuration > PEG Port Feature Configuration > VMD setup menu Stop Grant Configuration [Auto] VT-d [Enabled] [Disabled]...
  • Page 54: Memory Configuration

    VPX3-TL BIOS 4.1.1 Memory Configuration Aptio Setup – AMI Chipset Memory Configuration Memory RC Version 2.0.2.8 Memory Speed 3200 MT/s Memory Timings (tCL-tRCD-tRP-tRAS) 22-22-22-52 Controller 0 Channel 0 Slot 0 Populated & Enabled Size 16384 MB (DDR4) Number of Ranks...
  • Page 55: Graphics Configuration

    VPX3-TL BIOS BIOS Item Options Description Enable both DIMMs, Controller 0, Channel 0 DIMM Control Controller 0, Channel 0 Disable DIMM0, Support - Enable or Disable Dimms on DIMM Control Disable DIMM1, Controller 0, Channel 0. Disable both DIMMs Enable both DIMMs,...
  • Page 56: Peg Port Feature Configuration

    VPX3-TL BIOS Auto, Elk Creek 4, Select PCIE Card Select the card used on the platform PEG Eval > External Gfx Card Submenu Primary Display Configuration Internal Graphics Auto, Disabled, Enabled Keep IGFX enabled based on the setup options. GTT Size...
  • Page 57: Vmd Setup Menu

    VPX3-TL BIOS BIOS Item Options Description Detect Non-Compliance Disabled Detect Non-Compliance PCI Express Device Device Enabled in PEG 4.1.4 VMD setup menu Aptio Setup – AMI Chipset VMD Configuration Enable VMD controller [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 58: Pch-Io Configuration

    VPX3-TL BIOS 4.2 PCH-IO Configuration Aptio Setup – AMI Chipset PCH-IO Configuration > SATA And RST Configuration > USB Configuration > Security Configuration > HD Audio Configuration > SerialIo Configuration > Pch Thermal Throttling Control > TSN GBE Configuration Port 80h Redirection...
  • Page 59: Sata And Rst Configuration

    VPX3-TL BIOS Disabled Enable/Disable Timed GPIO0. When Enabled disabled, it disables cross time stamp Enable Timed GPIO0 time-synchronization as extension of Hammock Harbor time synchronization. Disabled Enable/Disable Timed GPIO1. When Enabled disabled, it disables cross time stamp Enable Timed GPIO1 time-synchronization as extension of Hammock Harbor time synchronization.
  • Page 60 VPX3-TL BIOS > Software Feature Mask Submenu Configuration Disabled Enable PCH to aggressively enter link Aggressive LPM Support Enabled power state. SATA Controller Speed Default, Gen1, Gen2, Indicates the maximum speed the SATA Gen3 controller can support. Serial ATA Port 0...
  • Page 61: Software Feature Mask Configuration

    VPX3-TL BIOS 4.2.2 Software Feature Mask Configuration Aptio Setup – AMI Chipset Software Feature Mask Configuration HDD Unlock [Enabled] LED Locate [Enabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save &...
  • Page 62: Usb Configuration

    VPX3-TL BIOS 4.2.3 USB Configuration Aptio Setup – AMI Chipset USB Configuration xDCI Support [Disabled] USB2 PHY Sus Well Power Gating [Enabled] USB3 Link Speed Selection [GEN1] USB PDO Programming [Enabled] XHCI LTR Mode [Enabled] USB Overcurrent [Enabled] USB Overcurrent Lock [Enabled] ><: Select Screen...
  • Page 63: Security Configuration

    VPX3-TL BIOS 4.2.4 Security Configuration Aptio Setup – AMI Chipset Security Configuration RTC Memory Lock [Enabled] BIOS Lock [Disabled] Force unlock on all GPIO pads [Disabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help...
  • Page 64: Hd Audio Configuration

    VPX3-TL BIOS 4.2.5 HD Audio Configuration Aptio Setup – AMI Chipset HD Audio Subsystem Configuration Settings HD Audio [Enabled] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save & Exit...
  • Page 65: Serial Io Configuration

    VPX3-TL BIOS 4.2.6 Serial IO Configuration Aptio Setup – AMI Chipset SerialIo Configuration [Communication port UART0 Controller (COM)] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help F8: Previous Values F9: Optimized Default F10: Save & Exit...
  • Page 66: Pch Thermal Throttling Control

    VPX3-TL BIOS 4.2.7 PCH Thermal Throttling Control Aptio Setup – AMI Chipset Thermal Throttling Level [Suggested Setting] DMI Thermal Setting [Suggested Setting] SATA Thermal Setting [Suggested Setting] ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt. F1: General Help...
  • Page 67: Server Mgmt Menu

    VPX3-TL BIOS 5 Server Mgmt Menu This menu contains the settings for IPMI BMC in the system. Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit BMC Self Test Status PASSED BMC Device ID BMC Device Revision BMC Firmware Revision 1.05...
  • Page 68: System Event Log

    VPX3-TL BIOS 5.1 System Event Log Aptio Setup – AMI Server Mgmt Enabling/Disabling Options SEL Components [Enabled] Erasing Settings Erase SEL [No] When SEL is Full [Do Nothing] Custom EFI Logging Options Log EFI Status Codes [Error code NOTE: All values changed here do not take effect until computer is restarted.
  • Page 69: View Fru Information

    VPX3-TL BIOS 5.2 View FRU information Aptio Setup – AMI Server Mgmt FRU information Board Manufacturer ADLINK Board Product VPX3-TL Board Serial Number PPS0000001 Board Part Number 55-31129 Product Manufacturer ADLINK Product Name VPX3-TL Product Part Number 91-31129 Product Version...
  • Page 70: Bmc Network Configuration

    VPX3-TL BIOS 5.3 BMC network configuration Aptio Setup – AMI Server Mgmt --BMC network configuration-- ********************** Configure IPv4 support ********************** Lan channel 1 Configuration Address source [Unspecified] Current Configuration Address StaticAddress source Station IP address xxx.xxx.xxx.xxx Subnet mask xxx.xxx.xxx.xxx Station MAC address...
  • Page 71: Adlink Ipmi Configuration

    VPX3-TL BIOS 5.4 ADLINK IPMI Configuration Aptio Setup – AMI Server Mgmt PCB Version Geographical Address 0x1C System Controller Host NVMRO Signal Non Protect Heater Status IPMI Product ID PCIe SKU NVMRO item Control [Non-Protect] REF_CLK Support [Enabled] AUK_CLK Support...
  • Page 72: Security Menu

    VPX3-TL BIOS 6 Security Menu This menu contains the settings for security in the system. Aptio Setup – AMI Main Advanced Chipset Boot Security Save & Exit Password Description If ONLY the Administrator’s password is set, then this only limits access to Setup and is Only asked for when entering Setup.
  • Page 73 VPX3-TL BIOS BIOS Item Options Description HDD Security Submenu For HDD security, it will list all HDD Configuration detected on motherboard. Select the then press enter figure/clear HDD password. Secure Boot menu Submenu When selecting a HDD to configure passwords, BIOS will enter another new BIOS setup page like below.
  • Page 74: Secure Boot

    VPX3-TL BIOS 6.1 Secure Boot Aptio Setup – AMI Security System Mode User Secure Boot [Disabled] Not Active Secure Boot Mode [Standard] > Restore Factory Keys > Reset To Setup Mode > Key Management ><: Select Screen ^v: Select Item Enter: Select +/-: Change Opt.
  • Page 75: Boot Menu

    VPX3-TL BIOS 7 Boot Menu This menu contains the settings for bootable devices in the system. Aptio Setup – AMI. Main Advanced Chipset Server Mgmt Security Boot Save & Exit Boot Configuration Setup Prompt Timeout Bootup NumLock State [On] Quiet Boot...
  • Page 76 VPX3-TL BIOS Boot Option #1~#11 Hard Disk Set system boot order. NVME CD/DVD USB Hard Disk USB CD/DVD USB Key USB Floppy USB Lan Network Disabled...
  • Page 77: Save & Exit

    VPX3-TL BIOS 8 Save & Exit Aptio Setup – AMI Main Advanced Chipset Server Mgmt Security Boot Save & Exit Save Options Exit system setup after Save Changes and Exit saving the changes. Discard Changes and Exit Save Changes and Reset...
  • Page 78: Important Safety Instructions

    VPX3-TL BIOS Important Safety Instructions For user safety, please read and follow all instructions, WARNINGS, CAUTIONS, and NOTES marked in this manual and on the associated equipment before handling/operating the equipment. 1. Read these safety instructions carefully. 2. Keep this user’s manual for future reference.
  • Page 79 VPX3-TL BIOS 8. This equipment is not suitable for use in locations where children are likely to be present. 9. Equipment must be serviced by authorized technicians when: • The power cord or plug is damaged; • Liquid has penetrated the equipment;...
  • Page 80: Getting Service

    6450 Via Del Oro, San Jose, CA 95119-1208, USA Tel: +1-408-360-0200 Toll Free: +1-800-966-5200 (USA only) Fax: +1-408-600-1189 Email: info@adlinktech.com ADLINK Technology (China) Co., Ltd. 上海市浦东新区张江高科技园区芳春路 300 号 (201203) Address: 300 Fang Chun Rd., Zhangjiang Hi-Tech Park, Pudong New Area Shanghai, 201203 China Tel: +86-21-5132-8988 Fax: +86-21-5132-3588 Email: market@adlinktech.com...

Table of Contents