PRODUCT STRUCTURE
![RENPHO - R-G001 - PRODUCT STRUCTURE PRODUCT STRUCTURE]()
SPECIFICATION
Product Name: Eye Massager
Model: R-G001
Input: 5V
1A
Rated Power: 5W
Default Auto-off Timer: 10 minutes
Battery Capacity: 1050mAh
Product Weight: 230g
Product Size: L196×W78×H82mm
Operation Frequency: 2402-2480MHz
Transmit Power: 8.81dBm MAX
WHAT'S INCLUDED
1 x RENPHO Eye Massager
1 x USB Cable
1 x User Manual
USING THE PRODUCT
Charging
- Use the 5V charger (not included) to charge your eye massager.
- Insert USB cable into the socket of the mobile charger.
- Softly insert the USB plug into the socket of the device, making sure the USB cable is inserted in the right direction.
- While charging, the LED indicator will flash red. When done charging, the LED indicator will be purple.
- The charge duration will be about 2.5 hours. Disconnect the power adapter after charging is complete. Once fully charged, the massager can be used in 10-minute intervals up to 8 times.
- The massager and the adapter may become warm during normal charging process.
- Use time may differ depending on the operation mode.
- The device will not work while charging.
Wear this device
- Loosen the adjustable headband.
- Place the device around your head and tighten the headband to the appropriate fit.
- Be careful to ensure the device is not too tight around your head.
- Please make sure that you have removed your contact lenses, glasses, false eyelashes, etc. before using this device.
- Do not operate the device with wet hands.
Bluetooth Connection
- Turn on the device by long press the Power Button.
- Enable your mobile phone Bluetooth setting and search for "R-G001", an audio voice will confirm when the device is connected to Bluetooth.
- After successfully pairing your device, music can be pushed to the device for playing while massaging.
Indicator Introduction
Status | Indicator Display |
Normal Operation | Solid Purple |
Low Battery | Flashing Red |
Charging | Flashing Red |
Fully Charged | Solid Purple |
Over-voltage Charging (over 5V) | No light |
Operation
- Long press the Power Button to turn on the device. The massage will begin after the voice prompt is heard.
- Short press the Power Button to switch between modes. An audio voice will confirm mode change and an LED light will display the current mode.
Mode 1: Tension Relief Mode
Mode 2: Retinal Protection Mode
Mode 3: Youthful Radiance Mode
Mode 4: Regeneration Mode
Mode 5: Rhythmic Mode (Vibration sync to the music beat) - Long press the Power Button to stop using the device.
- A voice prompt will be heard when the device has been in operation for 10 minutes. An indicator light will go off and the device will automatically shut down.
Silent Mode & Voice Mode
Quick press the Power button twice to enter Silent Mode (without voice broadcast).
In the silent mode, quick press the Power button twice to switch back to the Voice Mode.
Warm Tips
- When using this device, it's recommended to keep your eyes closed, lean back in the chair and completely relax your body.
- Your vision will become blurry for a short period of time after use. Regular vision will return faster if eyes are kept closed for a short while.
TROUBLESHOOTING
Problem | Possible Cause | Solution |
Power-on failure | - Check whether the battery level is too low
- The time of pressing Power Button is too short
| - Please charge the battery timely
- Long press the Power Button for 2-3 seconds
|
Low massage intensity | - Battery level is low
- The headband is too loose
| - Charge the device
- Wear it tighter
|
Device turns off automatically | - Battery is Low
- 10 Minutes Automatic Shut-off
| - Charge the device
- Turn on the massager again
|
The product can't be charged | - The charge's voltage is too high
- Adapter is broken
| - Use 5V 1A/2A charger to charge
- Change another adapter
|
If you encounter other problems, turn off the device and contact us at support@renpho.com |
CLEANING AND MAINTENANCE
- Please turn off the power when cleaning, do not use corrosive detergents such as benzene or diluents to clean the product.
- Do not expose the device to excessive sun or hot temperature. When the device has not been used for over 3 months, recharge it before use.
- Do not place it next to a wall or on the ground or rooftop.
- Keep the device dry, clean, and away from rats.
- Do not place anything heavy on it. Always bring your product to a qualified professional for any service or repair.
- Do not disassemble the product yourself.
- Do not disregard the device with normal household waste at the end of its life; instead, follow local environmental regulations and guidance for disposal.
CUSTOMER SERVICE
Please feel free to contact us if you have any questions or concerns. RENPHO Customer Service Team guarantees a quick response and hassle-free solutions to any issue you may have within business hours.
Tel: +44(0)7434-666088 (UK ONLY)
Monday-Friday 9:00AM-5:00PM(GMT)
Email: support-eu@renpho.com(UK&EU)
*For defective products or the return of items, please contact us with your order number within the specified warranty period. DO NOT dispose of any product parts as they may be required for inspection/repair.
ATTENTION
READ THOSE INSTRUCTION
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, semental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision
- The appliance has a heated surface. Persons insensitive to heat must be careful when using the appliance.
- The battery must be removed from the appliance before it is scrapped.
- The appliance must be disconnected from the supply mains when removing the battery.
- The battery is to be disposed of safely.
- It must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
- This appliance contains batteries that are only replaceable by skilled persons.
- This appliance is not intended for use by persons (including children ) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Please read this instruction manual carefully before using. RENPHO assumes no responsibility for any consequences caused by misuse or failure to follow these instructions.
- DO NOT use if you have had an eye operation, or if you have any eye diseases such as glaucoma, cataract, and amotio retinae.
- Disabled people, and the elderly should only use this product when properly supervised.
- DO NOT use if you have any swelling in the eye area.
- If you feel any pain around your eyes, please discontinue using the device and consult a physician.
- DO NOT use in high temperatures or humid environments. Avoid direct exposure to the sun.
- DO NOT use the device with wet hands.
- Remove contact lenses, glasses, false eyelashes, hairpins, and hair accessories, etc before using.
- Only use the charger (5V 1A, not included) to recharge the eye massager.
- DO NOT clean the product with water; clean it with cotton soaked in alcohol.
- Avoid contact with sharp objects.
- DO NOT use this product while driving.
- If any fault or malfunction should occur during use, take it off immediately. Never attempt to disassemble or repair the device yourself.
- The device is for private use only and cannot be used as medical equipment. It is not intended for medical diagnosis, treatment, or commercial purposes.
- Use it in the morning and evening for no more than 10 minutes each time.
- Please keep this manual for future reference.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Need help?
Do you have a question about the R-G001 and is the answer not in the manual?
Questions and answers