STEP 4 OF 5
Use the Transmitter Info screen to check important information such as
runtime hours for warranty coverage, current band (underlined), selected
operating current * battery voltage *
power modes,
temperature.
STEP 5 OF 5
Click to return to the Main menu.
GLOSSARY DEFINITIONS
*TRANSMITTER OPERATING CURRENT
A reading of greater than 0.5 A or less than 0.05 A indicates electrical failure.
*TRANSMITTER BATTERY VOLTAGE
A voltage reading below 2.7 (alkaline), 3.2 (lithium) or 3.9 (LiR) indicates bad or depleted
batteries.
V2 TRANSMITTERS MULTIPOWER MODE INTRODUCTION
V2 transmitters have three power modes to balance signal strength and
battery life. V2 transmitters are etched with a "V2" on the stainless battery
compartment (not on the label) and have a multipower mode sticker around
the IR port.
DIGITAL CONTROL, INC
,
, and max recorded
DIGITRAK FALCON F2+
DCI DigiGuide
USER MANUAL
05.18.2024
64