Download Print this page

Digital Control DIGITRAK FALCON F2+ User Manual page 58

Advertisement

depth of the transmitter when it reaches the point below the locator. If a locator is
placed above ground level, such as to provide separation from interference, that height
must be added to the target depth.
Note: If using a Falcon Compact Display, only left/right steering information is available.
The locator used with the Falcon Compact Display must still have a target depth set.
This target depth can be any value.
USE DIFFERENT SCANS FOR UP AND DOWN BANDS
STEP 1 OF 10
The Jobsite Setup topic "Find Best Frequencies" describes how to run the
frequency optimizer, walk the bore to scan for
both bands at the point of highest noise. You need to be familiar with that
topic before reading this one.
For jobsites with extra-challenging interference, consider a scan-pick-pair of
the first band at the noisiest point (such as next to the power transformer),
then scan-pick-pair the second band at the second-noisiest point (such as
over railroad tracks). This gives you a specifically tailored band for each of the
two most difficult locations along your drill path.
To use different scans for the Up and Down bands, you must
pair the first band before scanning for a second band.
STEP 2 OF 10
Ensure all transmitters are powered off or more than 30.5 m away from the
locator.
STEP 3 OF 10
From the Main menu select
Transmitter options.
DIGITAL CONTROL, INC
DIGITRAK FALCON F2+
interference *
, then optimize
USER MANUAL
DCI DigiGuide
05.18.2024
58