Address call push-button automatically
The call push-button and connector on the back
are addressed by the automatic call push-button
addressing as follows. The addressing takes place
starting from the top downwards, and with a two-
rowed door station, counterclockwise automatically
upwards to the right (figure 11).
i
Door stations are automatically pre-configured
at the factory.
The menu entry
is selected.
nately with the entry
for cancel.
With
/
select the entry
addressing.
Confirm with
.
During the addressing, the display flickers.
Afterwards the display returns to the previous
menu entry
.
0/0
0/0
0/1
0/1
0/2
0/3
0/4
0/5
0/2
0/6
0/7
Figure 11: Module address and automatic call
push-button addressing
Set individual call push-button address/function
The menu entry
Set individual call push-button
address/function is selected and flashes.
Confirm the call push-button to be set.
The menu entry
flashes alternately with the
current address/function.
With
/
select the required address
or function
for light push-button,
door release push-button or
Confirm set address/function with
The device applies the setting and returns to
the previous menu entry.
4
Elcom Kommunikation GmbH - Gottfried-Leibniz-Str.1 - D-74172 Neckarsulm - www.elcom.de -
Display saved error codes
Video insert and call-button module errors that
occur during operation are stored in the the error
memory of the video insert for diagnosis.
Select menu entry
confirm with
If no error code exists
seconds and afterwards
If error codes are saved
flashes alter-
the module address and the error code.
Press button
for automatic
codes if necessary.
Press button
Error
code
0/F
0/E
0/4
0/D
0/C
0/B
0/A
0/3
0/9
0/8
Table 2: Error codes and counter actions
i
The memory should only be deleted once 5
error codes have been stored, so that new error
codes can be saved.
i
Identical error codes are only saved once.
Inserting door station
...
The system settings are complete.
for
Remove opening tool from housing.
for no function.
Insert door station and press down until it clicks
.
audibly into place simultaneously at the top and
bottom if possible (Figure 12).
.
with button
is displayed for 2
.
flashes followed by
/
, to call up further error
to return to menu entry
Error cause
Counter actions
Communication error
If the error per-
between camera in-
sists, the call
sert and call push-but-
push-button
ton module. Once the
module must be
error has occurred 3
replaced.
times, the system is
reset automatically
and the error code is
generated.
sticking call button
Check call
push-button
module, and if
there is a defect,
replace and
address.
Writing of the call
If the error per-
push-button address
sists, the call
in the call push-button
push-button
module fails.
module must be
replaced and
addressed.
Figure 12: Insert door station
Align camera
The camera can be aligned in order to adapt the
camera picture to the local circumstances (Figure
14 and 15).
The door station is installed.
/
and
Loosen the locating screw for the camera
1.5 mm with the Allen key supplied (Figure 13).
Call an indoor station video from the door sta-
tion by call push-button.
.
Figure 13: Alignment of the camera
Align camera (figure 14/15).
The entrance area is clearly visible on the
display of the indoor station.
Fix camera again with screw (4).
1
2 m
2 m
1
0
1
2
Figure 14: Vertical camera orientation
2
1
0
2
1
Figure 15: Horizontal camera orientation
(4)
vertical
aperture angle
vertical
swivelling range
1
2 m
horizontal ap-
erture angle
horizontal
swivelling range
6LE000714A - 06/2015
Need help?
Do you have a question about the REQ5 Y Series and is the answer not in the manual?
Questions and answers