Chapter 3 - Handling of Control Panel CDP 31x
IV A
3 - 6
Step
Function
1.
To enter the Parameter Mode
Selection
2.
To select another group.
While holding the key down,
only the group number and
name is displayed. When the
key is released, number, name
and value of the first pin/ pa-
rameter in the group are dis-
played.
3.
To select a element.
While holding the key down,
only the element number and
name, representing a pin/ pa-
rameter, is displayed. When the
key is released the value of the
element is also displayed.
4.
To enter the Pin/Parameter Set-
ting Mode.
5a.
To change the Parameter
value:
5b.
To change the Pin connection
at first: (group number)
then:
(element number)
of the target.
6a.
To send the new value to the
drive.
6b.
To cancel the new setting and
keep the original value press
any key before pressing
The selected Keypad Mode is
entered.
3ADW000055R0401_DCS500B_Operating Instruction_e_d
Press key
(slow change)
(fast change)
--->
--->
ACT
ENTER.
FUNC
DCS 500B / DCP 500B Operating Instructions
Display after key is
pressed
0 L
17 RAMP GENERATOR
01 RAMP.[IN]
PAR
119.03
0 L
21 SPEED MEASUREMEN
0 L
21 SPEED MEASUREMEN
01 TACHOPULS NR
2048
0 L
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
0 L
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
EMF SPEED ACT
0 L
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
ENTER
[EMF SPEED ACT]
0 L
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
[ANALOG TACHO]
0 L
2 ANALOG OUTPUTS
05 AO2.[IN]
[105.02]
0 L
ENTER
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
ANALOG TACHO
PAR
0 L
21 SPEED MEASUREMEN
02 SPEED MEAS MODE
DRIVE
EMF SPEED ACT
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00
0.0 rpm 00