Unable to take meter reading
You are unable to take a meter reading when you push the shutter release button halfway.
The mirror may be locked up, or the RE ACTIVATION setting may be set to MANUAL.
1.
Push the mirror lock button to make sure that the mirror is down.
2.
Set RE ACTIVATION to RELEASE BTN.
Holding the shutter release button halfway activates the metering.
No image in viewfinder
When you look through the viewfinder, you are unable to see the scene.
The mirror may be locked up, or the lens may be incompatible. Non-PQ/PQS lenses are not compatible with
the Leaf AFi camera system.
1.
Push the mirror lock button to make sure that the mirror is down.
2.
Remove the lens from the camera system, and replace it with a compatible lens.
The compatible lens behaves as expected, and the image appears in the viewfinder.
Unexpected ISO
The ISO shown in the handgrip display is not what you expected.
This can occur when the ISO was not set on the imaging module. The imaging module overrides the ISO
set on the camera.
Set the ISO on the imaging module.
The correct ISO is shown in the handgrip display.
Unexpected ISO
207