9.
Error messages on the controls' display (optional and only for service staff)
Display
Causes
The
motor
HOT
temperature was exceeded
LOC
The control was locked
AST
The motor control unit expects a desk reset
e01
M1 – Overcurrent
E02
M2 – Overcurrent
E07
M1 – Hall error
E08
M2 – Hall error
control
unit's
operating
Rectification
Wait for the cooling-down period to end, see
Section 1.5.4
To unlock, you need a handset with a memory
button:
Press and hold the memory button for at least
8 seconds. During this time, LOC is still shown
on the display.
You can release the memory button as soon
as the desk height is shown on the display
again. The hand switch is now unlocked.
Reset the desk as described in Section 6.
Have you exceeded max. load? Remove the
load from the desk.
If the error persists, contact our Customer
Service.
Connection to the motor has been interrupted
or a new motor has been connected.
Check the cable/plug connection to the
motors and reset the desk as described in
Section 6.
If the error persists, contact our Customer
Service.