Table only moves when the keys are
pressed for the 2nd time
Cable is defective
Handset is defective
Buttons were pressed while putting the
desk into operation
Maximum duty cycle duration exceeded
Handset does not work (neither display nor buttons)
Possible causes
Cable is not plugged in
Cable is not plugged in correctly
Faulty plug contact
Cable defective
The correct order for wiring was not
observed
Maximum duty cycle duration exceeded
Acoustic warning signal for the battery
Battery charge less than 10%
No adjustment of the desk possible and an acoustic warning signal for the battery
Battery charge less than 5%
Note: The PowerFail Detection of the motor control unit detects power failures and saves all
the relevant data before the voltage drops below a critical level.
In some exceptional cases, it is not possible to save the data.
A manual reset is necessary to rectify this error (see Section 6).
Note: If during the height adjustment the battery charge is no longer sufficient for the
operation, or the battery is removed from its holder, a manual reset may be required.
If a fault cannot be rectified as described, disconnect the power supply by unplugging the mains cable from
the socket or remove the battery from its holder. Wait a few minutes and then restore the power supply via
the mains cable or the battery, and then try to reinitialise the table!
If an error still occurs repeatedly, disconnect the power supply again and contact the customer service.
The slim handset is equipped with a capacitive sensor field. To
operate the handset, it is necessary to touch the sensor
surfaces in the area of the printed arrows. If the table does
not move after touching the handset. Please move your finger
at least 5 cm away from the hand control and then touch the
desired button again.
Do NOT move your finger on the sensor field, as this cannot be
clearly recognised as an operation of the handset.
Replace the handset
Replace the handset
Unplug the handset and then plug it back in without touching
the operating unit
Wait for the regeneration period to end, see Section 1.5.5
Rectification
Plug the cable into the designated socket labelled "HS"
Unplug the cable and then plug it back in correctly
Replace the handset
Interrupt the power supply via battery or mains adapter and
unplug the handset and then first plug the handset back in
and only then restore the power supply via the battery or
mains adapter.
Wait for the regeneration period to end, see Section 1.5.5
Please charge the battery as soon as possible so that it is not
damaged due to the low charge level.
It is possible to continue using the battery.
Please charge the battery immediately so that it is not
damaged due to the low charge level.
It is not possible to continue using the battery.