Technical specifications
Operating voltage
Power consumption
Contact rating:
- Resistive load
- Inductive load
Floor sensor
Control
Temperature control range
Ambient temperature range 0 °C to 35 °C
Frost protection
IP class
Protection class
Maximum cable size
Controller type
Software class
Pollution degree
Over voltage category
Installation Guide
220-240 V~, 50/60 Hz
OFF: <175mW
230 V ~ 16A/3680 W
Cos φ = 0,3 max . 1 A
NTC 15 kΩ @ 25°C, 3 m . (default)*
PWM (Pulse Width Modulation)
Floor temperature: 5 ˚C to 35 ˚C
(45 ˚C after breakout)
4 ˚C to 14 ˚C (default value 5˚C)
21
Class II -
1 x 4 mm2 or 2 x 2,5mm2
1B
A
2 (Domestic use)
III
Idle: <200mW
/terminal
15

Advertisement