Installation Guide
DEVIreg™ 532
Electronic Thermostat
www.DEVI.com

Advertisement

loading

Summary of Contents for Danfoss DEVIreg 532

  • Page 1 Installation Guide DEVIreg™ 532 Electronic Thermostat www.DEVI.com...
  • Page 3: Table Of Contents

    DEVIreg™ 532 Table of Contents Introduction ..... . . Technical Specifications ... . Safety Instructions .
  • Page 4: Technical Specifications

    DEVIreg™ 532 Technical Specifications Operation voltage 220-240 V~, 50 Hz Standby power Max 0.25 W consumption Relay: Resistive load Max 15 A / 3450 W @ 230 V Inductive load cos φ= 0.3 max 1 A Sensing units NTC 15 kOhm at 25 °C Sensing values: 0 °C 42 kOhm...
  • Page 5: Safety Instructions

    DEVIreg™ 532 Type Storage temperature -20 to +65°C IP class Protection class Class II - Dimensions 85 x 85 x 36 mm Weight 90 g The product complies with the EN/IEC Standard «Automatic electrical controls for household and similar use»: •...
  • Page 6: Mounting Instructions

    DEVIreg™ 532 • The thermostat must be connected to a power supply via an all-pole disconnection switch. • The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended. • Always connect the thermostat to continuous power supply.
  • Page 7 DEVIreg™ 532 Always install the thermostat at least 50 cm. from windows and doors. Do not place the thermostat in a way that it will be exposed to direct sunlight. Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor.
  • Page 8 DEVIreg™ 532 Follow the steps below to mount the thermostat: Open the thermostat: • Press the release tab in the bottom of the thermostat using a flat object. • Carefully detach the front cover. • Carefully detach the frame. Installation Guide...
  • Page 9 DEVIreg™ 532 Connect the thermostat according to the connection diagram. LOAD LOAD Mains Max. Load 220-240V~ 15 (1) A IP31 -10T30 D532 The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
  • Page 10: Settings

    DEVIreg™ 532 Settings How to change the minimum and maximum floor temperatures Remove the adjustment button. Move the pins to the desired positions. Put the adjustment button back in place. Note: Please be aware of the following: • The floor temperature is measured where the floor sensor is placed.
  • Page 11 DEVIreg™ 532 Details Thermal Examples of Approximate resistance flooring setting for [m²K/W] 25 °C on top surface of floor 8 mm HDF based 0.05 > 800 kg/m³ 28˚C laminate 14 mm beech 650 - 0.10 31˚C parquet 800 kg/m³ 22 mm solid oak 0.13 >...
  • Page 12: Warranty

    The DEVIwarranty shall not extend to products which have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers.
  • Page 13 DEVIreg™ 532 Installation Guide...
  • Page 14: Disposal Instruction

    DEVIreg™ 532 Disposal Instruction Installation Guide...
  • Page 15 DEVIreg™ 532 Danfoss A/S Nordborgvej 81 6430 Nordborg, Syddanmark Denmark 08091218 & AN418534529476en-010102 © Danfoss | 2023.03...