6
English
with, it is easier to get that angle before starting. The spring (SPR)
angle is usually 38° or 45° for crown molding.
This is done by placing the molding as on the picture. Once the arms are
set to matching the angle of the item, press the HOLD/SUP button (6) for
~2 sec to get the supplemental angle. That will be the spring (SPR) angle.
EX: Angle between arms = 135°
Supplemental angle = 45°
Step 1: Start compound mitre mode. Press the MITRE button (8) for ~2 sec.
The SPR indicator (16) will flash and the SPR angle that was last stored into
memory will be shown for ~2 sec.
Step 2: The SPR indicator (16) will stop flashing and the display will again
show the active angle. If the stored SPR angle needs to be changed, adjust
the arms (3 and 5) until the displayed angle matches the known spring
angle (typ. 38° or 45°). Then press the MITRE button (8) for ~2 sec. The
displayed angle and SPR will flash once and the spring (SPR) angle is now
stored in memory.
If the stored spring angle does not need to be changed, press MITRE but-
ton (8) for ~1 sec to move to the next step.
Step 3: If you do not already have the CNR indicator (14) shown in the dis-
play, press the MITRE button (8) for ~1 sec. The CNR indicator will flash and
the CNR angle that was last stored (14) into memory will be shown for ~2
sec. The CNR indicator (6) will stop flashing and the display will again show
the active angle. If the stored CNR angle needs to be changed, adjust the
arms (5 and 8) as shown on the picture. To store the corner angle into
memory,