Echoflex Installation Guide
DMX Scene Controller
Connect 24 VDC
An external 24 VDC (Class 2) power supply is required to power the DMX
Scene Controller. Terminate to the DMX Scene Controller terminals
labeled 24 VDC.
Terminals accept 0.4–2.5 mm
[16 AWG] black-and-red wire pair).
1. Strip 9–10 mm (3/8 in) of insulation from the end of each wire.
2. Loosen the two screw 24 VDC screw terminals (+ and –).
3. Insert the negative wire (black wire typical) into terminal 1
(identified with a – symbol), and insert the positive wire (red wire
typical) into terminal 2 (identified with a + symbol).
4. Secure the screws firmly onto each wire.
Set Space
The DMX Scene Controller participates in an Elaho system using the
configured Space which is selectable using the rotary switch on the front
of the unit.
Set the Space rotary switch to the desired Space number for this
controller. All devices that are in the same Space will share control of the
connected Elaho stations and sensors.
Set Configuration Mode
The "Config Mode" switch allows selection between Basic and Custom
configurations of the DMX Scene Controller. Custom is the factory
default setting.
Custom
Set the switch to Custom configuration mode to apply the settings that
are supported by ElahoAccess.
See the ElahoAccess Mobile App integrated help system for details about
available configurable device parameters and actions available on the
DMX Scene Controller including:
• Configurable preset fade times
• Zone patch for intensity or color LED fixture control
• DMX speed
• Configuration of space raise/lower commands to affect unpatched
DMX addresses
DMX Scene Controller