COLD WATER TROUBLESHOOTING INDEX
1. Cold Water is not Cold (5°C +/- 3°C)
Possible Reason
No power or refrigeration
elements
Tank has run out of cold water.
Cold tank capacity is 4 litres for
Tower and 2 litres for Counter
Top.
Cold Water Thermostat
Refrigerant has run out
Compressor problem
WL2000IT Manual
Check that the Red Heater and Compressor
switch is on.
Turn Red Heater and Compressor Switch on.
I = ON
Wait for cold tank to chill water to temperature prior to
dispensing more cold water.
A greater capacity of Waterlogic Water Systems is available.
Check continuity of thermostat with multimeter. Replace
thermostat as required.
Run compressor for at least ten minutes. If condenser is not
warm, then refill the refrigerant.
If Compressor is not running, repair or replacement is
needed.
Solution
Page 55 - Revision:EU-2020-10-13