6. Restricted Flow of Hot Water
Possible Reason
Partially closed water supply valve to
the unit.
Hot Tank outlet hole is scaled over.
Tubing is creased or has a "kink" in it. Inspect and replace tubing as necessary.
Faucet nipple screen mesh has
obstruction(s)
Exhausted Filter
Solenoid connection to the Display
PCB
Solenoid Valve is Malfunctioning
WL2000IT Manual
Open water supply valve.
Descale Tank.
Unscrew faucet nipple from faucet and remove any
obstruction(s) from screen mesh.
Replace the Filter
Turn power off; unplug the unit and visually inspect
solenoid connections into the Display PCB. Verify the
soldering points on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Inspect valve components for proper function. Replace as
necessary.
Solution
Page 49 - Revision:EU-2020-10-13