Incorrect mounting:
5.3. DMX 512 operation
The ArcPower Unit Pixel is equipped with 5-pin XLR sockets for DMX input and output. Only use a shielded
twisted-pair cable designed for RS-485 and 5-pin XLR connectors in order to connect the fixture with the DMX
controller or one fixture with another.
To build a DMX chain.
1. Unplug ArcPower Unit Pixels from the mains before installation.
2. Connect the LED modules to the ArcPower Unit Pixels.
3. Connect ArcPower Unit Pixel s each other. Max. 32 fixtures may be connected on a DMX link.
Terminate the DMX link by installing a termination plug in the output of the last fixture.
The termination plug is a male 5-pin XLR plug with a 120 Ohm resistor soldered between Signal (–)
and Signal (+).
4. Connect ArcPower Unit Pixels to mains.
5. Set each ArcPower Unit Pixel.
6. Connect the DMX controller to the first fixture.
9