Eminere Inground Wireless DMX FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
Eminere Inground Wireless DMX Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g.
Eminere Inground Wireless DMX 3.1 Mounting the Eminere Inground Warning! If the Eminere Inground will be exposed to max. allowed static load, the subsoil under the installation sleeve has to withstand load of: 45kN (standard covering glass) 23kN (antiskid covering glass). Example of installation of the Eminere Inground 2 1.
Page 6
Eminere Inground Wireless DMX The supply cable to the mounting sleeve and power/data cable from the mounting sleeve must be placed in a protective tube (12). 6. After connecting cables to the junction box (8), screw the Eminere Inground (13) to the mounting sleeve (1) by means of the four countersunk- allen head bolts M5x18 (14).
Page 7
Eminere Inground Wireless DMX Junnction box The Eminere Inground is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC power source from 120-277 Volts. Do not connect (disconnect) Emineres Inground each other when they are under voltage! 1.
Page 8
Eminere Inground Wireless DMX Cable gland M20: We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body in case that you need to unscrew and remove the cable gland from the housing of the junction box and and screw it back to the housing.
Page 9
Eminere Inground Wireless DMX Junction box filled with resin. Earth wire 4. Screw the cover (18) with gasket (19) to the junction box by means of the four screws (17) and check they are fully tighten. 8. If you install two or more Emineres Inground side by side, you have to screw three types of the cover plates: end (15), middle (23) and continuous (22).
Page 10
Eminere Inground Wireless DMX Cover plates overview: Single fixture End fixture in a row of fixtures Middle fixture in a row of fixtures (15)-Cover plate end (optional ) (22)-Cover plate continuous (optional) (23)-Cover plate middle (one piece is a standard part of fixture) 9.
Page 11
Eminere Inground Wireless DMX DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager. Direct visibility between a transmitter and the Eminere Inground Wireless DMX must be ensured without no obstacles (bildings, trees, cars..).
Page 12
Eminere Inground Wireless DMX DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager. Theoretically up to 32 Emineres Inground can be connected in DMX chain, but number of connected Emineres Inground in series also depends on their cable length, power voltage and type of Emineres Inground.
Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, non- abrasive washing detergent. Rinse it. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts.