Listening Volume. Mix Leveling; Speaker Volume And Settings - Altair IPcom Series User Manual

16 key intercom panel station
Table of Contents

Advertisement

Listening volume. Mix leveling

Each channel will show a bar at the bottom that indicates the listening level setting. In addition, said bar will
be blue when listening is active or gray when it is deactivated -muted-.
Each channel of the IPF-316 panel has its individual listen volume control and there is also a general volume
adjustment.
To adjust the overall listening volume, turn the VOLUME rotor encoder.
To adjust the listening volume of an individual channel, hold up the LISTEN/TALK key of the corresponding
channel and turn the VOLUME rotor located on the right side of the IPF-316 front panel.
You can adjust leveling mix on the NEBULA soft program.
Go to USERS > ADVANCED SETTINGS > AUDIO and find the mixer of available channels on MIX section:
TALK and LISTEN This switches works in parallel to correspondent keys on the front panel. Helps administration.
LOCK This switches locks Talk/Listen switches of the correspondent channel avoiding in-advert manipulation

Speaker volume and Settings

The internal speaker and external speaker output can be activated or deactivated by the SPEAKER key.
To adjust the volume of the Internal Speaker, hold down the SPEAKER key and at the same time turn the
VOLUME rotor located on the right side of the IPF-316 front panel.
By MENU settings: Enter the menu option AUDIO and then SPEAKER to set it at your choice.
By NEBULA software you can set the level and the activation key remotely and some important parameters:
Speaker Attenuation by Panel Microphone. Set the attenuation of the speaker when Panel Mic is
activated. This function reduced the Talk contamination to the open channels due to presence of
various signals present on the speaker.
NOTE. The attenuation affects only to the LISTEN of group whose TALK is opened
Speaker Attention by Neighbor. It is possible to reduce the speaker level from a channel shared
within a unit or some units in the physical proximity to our unit. You can set the Attenuation level
due to the correspondent defined Neighbor. Attenuation set would be depends of distance, level etc.