LTPOWERPLAY QUICK START PROCEDURE
d. If you want to set the output voltage to be 24V. In the
Config tab, type in 50 in the MFR_VOUT_COMMAND_
LTC7841 box. Then the V
is set to ~1.2V.
e. In order to turn on the power stage, click the "Apply
an operation to all devices" icon
internal reference voltage
OUT
DEMO MANUAL DC2798A
f. In the popup "Apply an operation to all devices" dialog
box, click the "On" button to turn on the power stage
g. After the test, in the popup "Apply an operation to all
devices" dialog box, click the "Immediate Off" button
to turn off the power stage.
Rev. 0
7
Need help?
Do you have a question about the Linear ADI Power DC2798A and is the answer not in the manual?