Backyard Products GAMBREL Assembly Manual
Backyard Products GAMBREL Assembly Manual

Backyard Products GAMBREL Assembly Manual

12' x 24' (365,8 x 365,8 cm) actual floor size: 144" x 288" (365,8 x 365,8 cm)
Hide thumbs Also See for GAMBREL:

Advertisement

!
DO NOT RETURN
TO THE STORE!
If you discover missing or damaged parts,
or if you have questions about the building process,
please reach out to us directly for the fastest service.
24/7 Support
help.backyardproducts.com
Call a Recruiter Today! 734-365-7000
Flexible schedule
*based on number of completed installations
STOP
Answers to frequently
asked questions
Technical assistance and
how-to videos
Submit a help request
Request replacement parts
Did you enjoy building your shed?
JOIN OUR TEAM
AND MAKE UP TO $1,500/WEEK*
No selling,
just building
Business Hours
(734) 242-6900
Monday - Friday ........... 8:00am - 6:00pm EST
Saturday - Sunday .................................Closed
Bonus incentives
available
16957

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAMBREL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Backyard Products GAMBREL

  • Page 1 16957 STOP DO NOT RETURN TO THE STORE! If you discover missing or damaged parts, or if you have questions about the building process, please reach out to us directly for the fastest service. 24/7 Support Business Hours help.backyardproducts.com (734) 242-6900 Answers to frequently Monday - Friday ...
  • Page 2 $500 gift card. Write a Backyard Products, LLC. product review at backyardreviews.net for a chance to win a $500 Visa gift card. No purchase necessary to enter. Must be legal U.S. resident (including DC & Puerto Rico), 18 or older to participate. Taxes on prize are responsibility of winner. Odds of winning depend on the number...
  • Page 3: Assembly Manual

    Backyard Products, LLC ASSEMBLY MANUAL 1000 Ternes Drive Monroe, MI 48162 GAMBREL 12' x 24' (365,8 x 365,8 cm) ACTUAL FLOOR SIZE: 144" x 288" (365,8 x 365,8 cm) KEEP THIS MANUAL FOR FUTURE REFERENCE Eave Door with Optional Windows (Instruction for window installation located in window kit.)
  • Page 4 TOOLS Required Optional Phillips Tool Belt/ Utility Knife Screwdriver Nail Pouch Shingle Blades Drill / Driver Caulk Gun 1/8" Drill Bit Tin Snips 1/4" Drill Bit (for drip edge) 5/16" Drill Bit Paint Tools 1/2" Drill Bit #2 Philips Drive Bit Chalk Line Safety Glasses Hammer...
  • Page 5: Optional Materials

    ADDITIONAL MATERIALS FOUNDATION OR FLOOR MATERIALS • If your purchase comes with a floor system, the materials to construct your floor will be in a separate kit(s). • See the FLOOR LEVELING section on page 15 for recommended methods and suggested materials to properly level your floor, as this will vary depending on your specific site.
  • Page 6: Parts List

    PARTS IDENTIFICATION AND SIZES WOOD SIZE CONVERSION CHART Part identification letters are stamped on some parts. Treated lumber is stamped: Nominal Board Size Actual Size 2 x 4 ....1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1 x 4 ....3/4" x 3-1/2" (1,9 x 8,9 cm) 2 x 3 ....1-1/2"...
  • Page 7 FLOOR FRAMING (IF DIY FLOOR KIT(S) PURCHASED) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) TREATED 2 x 4 x 93" (5,1 x 10,2 x 236,2 cm) TREATED TREATED 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) 3"...
  • Page 8 FASTENER/HARDWARE BAG NOTE: 1-1/2" (3,8 cm) x110 If you are using a nail gun, nails 2" (5,1 cm) may be used where screws are x200 shown for quicker assembly. 3" (7,6 cm) x117 Length of nail must match screw length. 2"...
  • Page 9 COMPONENT SECTION INDEX Description Section Page Floor 9-16 Walls 21-44 Rafters 18-19, 46 Gable Units 47-49 Roof Panels Fascia Trim Doors Corner Trim Collar Ties 66-67 Windows Shingles...
  • Page 10 CONCRETE FOUNDATION If you choose to install your kit on a concrete slab refer to the diagram below. Treated Sill Plate Caulk between sill plate and concrete. 3-1/2" (8,9 cm) 4" (10,2 cm) Building Size Actual Size 12' x 24' (365,8 x 731,5 cm) 144"...
  • Page 11 BUILD YOUR OWN WOOD FLOOR OPTION (Materials not included.) 141" (358,1 cm) 288" (731,5 cm) 144" (365,8 cm) 16" (40,6 cm) 16" (40,6 cm) MATERIAL REQUIRED 2 x 4 x 12' (5,1 x 10,2 x 365,8 cm) MUST be treated lumber 4 x 4 x 12' (10,2 x 10,2 x 365,8 cm) MUST be treated lumber 5/8"...
  • Page 12 BUILD YOUR OWN WOOD FLOOR OPTION LEVEL AND SQUARE FLOOR FRAME Before attaching fl oor decking, it is important to level and square the fl oor frame. A level and square fl oor frame is required to correctly construct your shed. BEGIN See page 14 for the preferred fl oor leveling method.
  • Page 13: Parts Required

    FLOOR FRAME (IF DIY FLOOR KIT(S) PURCHASED) PARTS REQUIRED: x132 3" (7,6 cm) NOTE: TREATED Look for Stamp. 2 x 4 x 48" (5 x 10 x 122 cm) TREATED 2 x 4 x 93" (5 x 10 x 236,2 cm) TREATED 2 x 4 x 96"...
  • Page 14 FLOOR FRAME (IF DIY FLOOR KIT(S) PURCHASED) PARTS REQUIRED: x108 3" (7,6 cm) Fasten (3) fl oor sections together, as shown. Secure with 3" nails. Flush Flush 288" (731,5 cm) Stagger nail pattern. Flush Flush 144" (365,8 cm) FINISH Your fl oor frame is now assembled. Proceed to level and square frame.
  • Page 15 LEVEL AND SQUARE FLOOR FRAME Before attaching fl oor decking, it is important to level and square the fl oor frame. A level and square fl oor frame is required to correctly construct your shed. BEGIN See page 14 for the preferred fl oor leveling method. Use a level and check that the frame is level before installing fl oor panels.
  • Page 16 OPTIONAL WOOD FRAME FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below. Leveling materials are not included in this kit. PREFERRED METHOD - 4x4 TREATED RUNNERS Runners are generally 12" (30,5 cm) from ends of floor frame and •...
  • Page 17 FLOOR PANELS (IF DIY FLOOR KIT(S) PURCHASED) PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE BLOCK 5/8 x 48 x 96" (1,6 x 121,9 x 243,8 cm) Install floor panels with the rough side facing up (painted grid lines). BEGIN Install (1) 48" x 96" panel on one of the 96" x 144" floor frame sections, edge flush to the seam between the floor frames and 3/4"...
  • Page 18 FLOOR PANELS (IF DIY FLOOR KIT(S) PURCHASED) PARTS REQUIRED: x546 2" (5,1 cm) 3/4" GAUGE BLOCK 5/8 x 48 x 96" (1,6 x 121,9 x 243,8 cm) Continue installing the remaining panels in the following order: 1. 48 x 96" (A) 2.
  • Page 19 IMPORTANT! Ensure that the floor frame is level after installing floor panels. Re-level if necessary. • The floor should used as a stable work surface for wall construction. • Organize your assembly procedure during the build process HINT: to avoid over-handling of the walls. GABLE WALL EAVE WALL EAVE WALL...
  • Page 20: Rafter Assembly

    RAFTER ASSEMBLY PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 7" (5,1 x 10,2 x 17,8 cm) Build a rafter jig using the floor and (2) AL parts. BEGIN Measure 49-3/4" at each side of floor, as shown. Mark measurements and snap a chalk-line at 49-3/4". Install 1st AL aligned with the chalk-line and flush to the floor deck on left side.
  • Page 21 RAFTER ASSEMBLY PARTS REQUIRED: x288 2" (5,1 cm) Pre-assembled 6 x 24" (15,2 x 60,9 cm) Build (2) rafter assemblies with (1) gusset (Fig. C). Place (2) pre-assembled rafters into the jig, as shown. Check all measurements. Align rafters fl ush to AL and fl ush rafter peaks together at the 72-3/8" mark on fl oor. While holding rafters securely in place, place gusset on rafters with a 1/4"...
  • Page 22: Window Installation

    WINDOW INSTALLATION If you purchased a shed with one or more windows, please see instructions located in the window kit for installation. You will install windows after your shed is assembled.
  • Page 23 WALL INDEX Create your own style of shed. Choose your door location. Use this guide to find the corresponding wall construction and installation pages. IMPORTANT! Build your door header before building any walls (see next page). After assembling the walls for your 12' x 24' shed, go to page 41 for wall installation.
  • Page 24 DOOR FRAME UNIT Assemble the door frame unit before building any walls! Any wall with a door will require this assembly. PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 67" (5,1 x 10,2 x 170,2 cm) 7/16 x 3-1/4 x 66-3/4" (1,1 x 8,3 x 170,2 cm) Pre-assemble the door header.
  • Page 25 WALL PANEL INSTALLATION HINTS & EXAMPLES PARTS REQUIRED: 2" (5,1 cm) TEMP. SPACER 3/4" GAUGE BLOCK 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) Ensure your wall is square by installing one panel and squaring frame. Install all wall panels with the primed side facing up.
  • Page 26 DOOR FRAME UNIT PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 7" (5,1 x 10,2 x 17,8 cm) 3" (7,6 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) Assembled Header 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) Arrange parts on edge on fl oor, as shown.
  • Page 27 GABLE WALL A PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) Assembled Door Frame Unit 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) BEGIN Arrange parts on edge on floor, as shown.
  • Page 28 GABLE WALL A PARTS REQUIRED: 3" (7,6 cm) x166 2" (5,1 cm) 23-7/8" x 84" (60,6 x 213,4 cm ) Temporary Brace 69" (75,3 cm) Door Stiffener 1-1/2" Flush (3,8 cm) Install the left panel 1-1/2" 3/4" BEGIN HERE (1,9 cm) from the top plate.
  • Page 29 GABLE WALL B PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) BEGIN Arrange parts on edge on floor.
  • Page 30 GABLE WALL B PARTS REQUIRED: x150 2" (5,1 cm) 48 x 84" (121,9 x 213,4 cm ) 3/4" BEGIN HERE 1-1/2" (1,9 cm) Install 48" x 84" panel (3,8 cm) 1-1/2" from the top plate. Use a 2x4 spacer for consistent measurement.
  • Page 31 EAVE WALL C PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 72" (5,1 x 10,2 x 182,8 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 96"...
  • Page 32 EAVE WALL C PARTS REQUIRED: x300 2" (5,1 cm) 48 x 84" (121,9 x 213,4 cm ) Install panels with the primed side facing up. Install (1) 48" x 84 panel 1-1/2" from the top plate. Use a 2x4 spacer for consistent measurement. Secure panel with 2"...
  • Page 33 GABLE WALL D PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) BEGIN Arrange parts on edge on floor.
  • Page 34 GABLE WALL D PARTS REQUIRED: x156 2" (5,1 cm) 48 x 84" (121,9 x 213,4 cm ) 3/4" BEGIN HERE Install 48" x 84" panel (1,9 cm) 1-1/2" from the top plate. 1-1/2" (3,8 cm) Use a 2x4 spacer for consistent measurement.
  • Page 35 EAVE WALL E PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 72" (5,1 x 10,2 x 182,8 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 96"...
  • Page 36 EAVE WALL E PARTS REQUIRED: x300 2" (5,1 cm) 48 x 84" 23-7/8" x 84" (121,9 x 213,4 cm ) (60,6 x 213,4 cm ) Install the fi rst 48" x 84" panel in the middle of frame, 1-1/2" from the top plate. Use a 2x4 spacer for consistent measurement.
  • Page 37 EAVE WALL F PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 72" (5,1 x 10,2 x 182,9 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 96"...
  • Page 38 EAVE WALL F PARTS REQUIRED: 3" (7,6 cm) Assembled Door Frame Unit Place the Door Frame Unit at measurements shown. Measure and mark from end of frame. Ensure 64" (162,8 cm) door measurement. Secure door frame unit with (2) 3" nails at each connection. 178-1/4"...
  • Page 39 EAVE WALL F PARTS REQUIRED: x294 2" (5,1 cm) 48 x 84" (121,9 x 213,4 cm ) Install the left panel 1-1/2" from the top plate. Use a 2x4 spacer for consistent measurement. Secure panel with 2" nails spaced 6" apart on edges. 3/4"...
  • Page 40 EAVE WALL G PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 72" (5,1 x 10,2 x 182,9 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 96"...
  • Page 41 EAVE WALL G PARTS REQUIRED: 3" (7,6 cm) Assembled Door Frame Unit Place the Door Frame Unit at measurements shown. Measure and mark from end of frame. Ensure 64" (162,8 cm) door measurement. Secure door frame unit with (2) 3" nails at each connection. 82-1/4"...
  • Page 42 EAVE WALL G PARTS REQUIRED: x294 2" (5,1 cm) 48 x 84" (121,9 x 213,4 cm ) Install the left panel 1-1/2" from the top plate. Use a 2x4 spacer for consistent measurement. Secure panel with 2" nails spaced 6" apart on edges. 3/4"...
  • Page 43 EAVE WALL C, F or G INSTALLATION PARTS REQUIRED: 3" (7,6 cm) Temporary Brace 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) 1-1/2" BEGIN Screws (3,8 cm) Center eave wall on the fl oor. 1-1/2"...
  • Page 44 GABLE WALL B INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 1-1/2" (3,8 cm) 3" (7,6 cm) 1-1/2" BEGIN Fig. B (3,8 cm) Install gable wall centered on fl oor. 1-1/2" (3,8 cm) overlap is to the top. 2"...
  • Page 45 (2nd) EAVE WALL C or E INSTALLATION PARTS REQUIRED: 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) Temporary Brace 1-1/2" (3,8 cm) 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) 1-1/2" (3,8 cm) BEGIN Install 24' eave wall centered on fl oor.
  • Page 46 GABLE WALL A or D INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 1-1/2" (3,8 cm) 3" (7,6 cm) Fig. B BEGIN 2" (5,1 cm) Place gable wall on fl oor centered between eave walls. Screw Secure wall with 2"...
  • Page 47 WALL DOUBLERS INSTALLATION PARTS REQUIRED: 3" (7,6 cm) x2 STL 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 92-1/2" (5,1 x 10,2 x 234,9 cm) 2 x 4 x 96"...
  • Page 48 RAFTER INSTALLATION PARTS REQUIRED: 3" (7,6 cm) Two-Gusset One-Gusset Assembled Assembled BEGIN Align rafters over the wall studs. Check that you have the measurements shown. Secure rafters with (2) 3" screws angled at each end (Fig. A, Fig. B). Secure gable end rafters with (1) 3" screw through top of rafter into doubler (Fig. C). Secure rafters on opposite side.
  • Page 49 GABLE HAY LOFT TRIM PARTS REQUIRED: 2" (5,1 cm) 3/4" (1,9 cm) 19/32" x 2-1/2" x 12-7/8" (1,6 x 7,6 x 32,7 cm) 19/32" x 3-1/2" X 21-3/4" (1,6 x 8,9 x 55,2 cm) 19/32" x 3-1/2" X 23-3/4" (1,6 x 8,9 x 60,3 cm) x1 LKA 19/32"...
  • Page 50 GABLE UNITS PARTS REQUIRED: 1-1/2" (3,8 cm) x4 QL 2 x 4 x 39" (5,1 x 10,2 x 99,1 cm) Install gable panels with the primed side facing up. BEGIN Place middle panel on (2) QL. Arrange parts to measurements shown. Secure panel with 1-1/2"...
  • Page 51 GABLE INSTALLATION PARTS REQUIRED: 3" (7,6 cm) x130 2" (5,1 cm) Assembled BEGIN Measure 1-1/2" (3,8 cm) down from top plate doubler and mark at each side as shown. Set gable unit on top plate. Fasten with (1) 2" nail on each side. BE SURE GABLE IS CENTERED ON WALL BEFORE NAILING.
  • Page 52 12' x 24' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE BLOCK 48 x 96" (121,9 x 243,8 cm) Roof panels may cause serious injury until securely fastened. Note: Install all roof panels with the rough side up (painted grid lines). BEGIN Flush at peak...
  • Page 53 12' x 24' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 48 x 96" 47-7/8 x 48" (121,9 x 243,8 cm) (121,6 x 121,9 cm) Flush at 1/2" peak (1,2 cm) Install 2nd 47-7/8" x 96" roof Fig. B panel flush to the installed panel, and flush at the peak Fig.
  • Page 54 12' x 24' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 12-1/2" x 96" 23-7/8" x 96" 23-7/8" x 48" (31,8a cm x 243,8 cm) 3/4" GAUGE (60,6 x 243,8 cm) (60,6 x 121,9 cm) BLOCK 11-7/8" x 96" 11-7/8" x 48" 12-1/2"...
  • Page 55 12' x 24' ROOF PANELS PARTS REQUIRED: x432 2" (5,1 cm) Secure all roof panels with 2" nails spaced 6" apart and 12" apart inside panels. 6" (15,2 cm) Repeat all steps to install roof panels on the opposite side. FINISH Your roof panels are now installed.
  • Page 56 GABLE FASCIA PARTS REQUIRED: 2" (5,1 cm) 5/8 x 4 x 36" (1,6 x 10 x 91 cm) 19/32" x 4 x 60-7/8" (1,6 x 10 x 154,6 cm) 5/8 x 4 x 36" (1,6 x 10 x 91 cm) 19/32"...
  • Page 57 DOORS PARTS REQUIRED: 1" (2,5 cm) #14 Screws LEFT Square Drive Bit RIGHT 5/4 x 3-1/2 x 72-3/8" (3,2 x 8,9 x 183,8 cm) ¸ BEGIN Arrange parts as shown on a flat surface. Align (6) hinges with pre-drilled holes in DJD and doors.
  • Page 58 DOORS PARTS REQUIRED: 3" (7,6 cm) 1" (2,5 cm) #14 Screws 3/16" (5 mm) Drill Bit Temporary Support Door Stiffener 69" (175,3 cm) Square Drive Bit Using holes in hinge as a guide, predrill (3) 3/16" holes 3/4" deep into door. Predrill (2) 3/16"...
  • Page 59 DOORS PARTS REQUIRED: 3" (7,6 cm) Temporary Support 2 x 4 x 60" (5,1 x 10,2 x 152,4 cm) 3" (7,6 cm) #14 Screws 3/8 x 3-1/2 x 83-1/2" (1 x 8,9 x 212,1 cm) Temporary Spacer (Not shown to scale) Install (2) SX as a temporary support ledger boards 3/8"...
  • Page 60 DOOR TRIM PARTS REQUIRED: 3/4" (1,9 cm) x11 2" (5,1 cm) Bagged seperately / special coating 5/4 x 3-1/2 x 24-5/8" (3,2 x 8,9 x 62,5 cm) 64" Metal Threshold 3/4" (1,9 cm) 5/4 x 3-1/2 x 74" (3,2 x 8,9 x 188 cm) BEGIN Secure door trim from inside using 3/4"...
  • Page 61 DOOR TRANSOM WINDOWS PARTS REQUIRED: 3/4" (1,9 cm) Transom Window ¸ BEGIN Apply high quality exterior-grade caulk behind frame near edge before installing to seal window. You must caulk completely around window frame and all exposed door panel edges and trim to validate your warranty.
  • Page 62 DOOR STIFFENERS PARTS REQUIRED: 2" (5,1 cm) 69" Door Stiffener (175,3 cm) BEGIN Center OO vertically on the left door in the door opening fl ush with the edge of door (Fig. A). Secure with (7) 2" screws through outside trim into OO (Fig. B) OO x2 Repeat steps to install OO on right door.
  • Page 63 DOOR HARDWARE PARTS REQUIRED: 1/4" (6 mm) Drill Bit 3/4" (19 mm) Drill Bit BEGIN Measure and mark location of hole on outside of right door as shown (Fig. A). Pre-drill hole with 1/4" drill. Re-drill hole with 3/4 " drill. Keep drilled hole square to trim to avoid breaking edge of door stiffener.
  • Page 64: Door Hardware

    DOOR HARDWARE PARTS REQUIRED: Hex Wrench, Square Drive Bit 3/32" (3 mm) Drill Bit 3/4" (19 mm) Phillips Head Screw #8 x 2" (5,1 cm) Square Drive Screw Pre-assemble, test-fi t parts and mark (2) pilot hole locations, as shown. Remove parts and pre-drill (2) 3/32"...
  • Page 65 DOOR WEATHERSTRIPPING PARTS REQUIRED: 2" (5,1 cm) 1 x 4 x 69-1/4" (2,5 x 10,2 x 175,9 cm) BEGIN Install (2) NUC weatherstrips fl ush along inside of doors and fl ush to door header. Secure with 2” fi nishing nails, as shown (Fig. A). Fig.
  • Page 66 DOUBLE DOOR HARDWARE PARTS REQUIRED: 5/16" BIT (8 mm) 3/4" (1,9 cm) BEGIN Place upper bolt on OO in open position with bolt end 3/8" (9,5 mm) down from frame. Bolt is open when loop is contacting base (Fig A). Mark and pre-drill holes for screws.
  • Page 67 CORNER TRIM PARTS REQUIRED: 2" (5,1 cm) 3/8" x 3-1/2" x 83-1/4" (1 x 8,9 x 211,5 cm) BEGIN Install gable end 83-1/4" corner trim under gable panel, (Fig. A) and fl ush to eave wall panel (Fig. B). Secure with 2" fi nishing nails spaced evenly. Install eave side 83-1/4"...
  • Page 68 COLLAR TIES PARTS REQUIRED: x120 2" (5,1 cm) 2 x 4 x 60" (5,1 x 10,2 x 152,4 cm) 7/16 x 3-1/2 x 24" (1,1 x 8,9 x 61 cm) BEGIN Arrange (2) SX end-to-end on fl at surface, fl ush in middle. Center collar tie gusset OSB on top of SX boards.
  • Page 69 COLLAR TIE INSTALLATION PARTS REQUIRED: 3" (7,6 cm) Assembled BEGIN Fig. A Install collar tie to the rafter with (3) 3" nails at each end (Fig. A). Flush to roof panel 3" (7,6 cm) Starting at the wall with the door, Nails install fi rst collar tie on the 2nd rafter from the wall and then on every other rafter, as shown.
  • Page 70 HOOKS & EYES PARTS REQUIRED: ¸ BEGIN Install hooks in wall and into wall framing (Fig.A). Swing door open to locate eye. Fig. A Hook Install hook into framing, if possible. FINISH You have installed your hooks & eyes.
  • Page 71 PAINT & CAULK - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: •...
  • Page 72 SHINGLES - NOT INCLUDED - • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. Notch Notch SHINGLE NAIL PATTERN 1/2" 1" Sealing Strip 1" (1,3 cm) (2,5 cm) (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS.
  • Page 73 SHINGLES continued... Install second row of shingles flush at top of first row's rain slots. Ensure 1" overhang or flush to drip edge at front, stagger each row. FRONT OF BACK OF SHED SHED Bend in roof 1" (2,5 cm) Notch Flush with rain slots.
  • Page 74 SHINGLES continued... After shingles are installed over bend, nail down overlap using two roofi ng nails per tab. (2) Nails per tab. Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below.
  • Page 75 SHINGLES - RIDGE CAP • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN Hint: Use cut-off pieces first. Cut shingles into THREE pieces. 2" 2" (5 cm) (5 cm 2" 2" 2"...
  • Page 76 SHINGLES - RIDGE CAP continued... Continue installing ridge cap to back of roof. Make sure there is 4" between the shingle-color and edge of shingles. 4" (10 cm) Trim cap off fl ush to shingles When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot.
  • Page 77 PURCHASED COMPONENTS Hardware Kit H/K HHP SERIES GAMBRELS 15739 Hardware Kit H/K ADDENDUM for THRESHOLD SC 15840 Hardware Kit H/K CLASSIC/HHP 4' GAMBREL 15673 H/K CLASSIC/HHP 8' GAMBREL 15691 Hardware Kit Threshold THRESHOLD 7/8" X 1-1/2" X 63-7/8 15420 PACKAGING...
  • Page 78 LIMITED CONDITIONAL WARRANTY* Backyard Storage Solutions, LLC warrants the following: Every product is warranted from defects in workmanship and manufacturing for 1 year. All accessories, hardware and metal components are warranted for 2 years. All Oriented Strand Board (OSB) is warranted for 2 years Siding and Trim is warranted for 10 years.