Advertisement

For questions on assembly or for general inquiries, you may contact us in the following ways:
Call a Recruiter Today! 734-365-7000
Flexible schedule
*based on number of completed installations
Call Us First!
DO NOT RETURN TO STORE.
Call customer service: 1-877-743-3400
AVOID THE WAIT!
visit us online at
help.backyardproducts.com
Submit a help request
Answers to frequently asked questions
Live chat with an agent
Did you enjoy building your shed?
JOIN OUR TEAM
AND MAKE UP TO $1,500/WEEK*
No selling,
just building
Bonus incentives
available
16410

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAMBREL 10 x 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Backyard Products GAMBREL 10 x 10

  • Page 1 16410 Call Us First! DO NOT RETURN TO STORE. For questions on assembly or for general inquiries, you may contact us in the following ways: Call customer service: 1-877-743-3400 AVOID THE WAIT! visit us online at help.backyardproducts.com Submit a help request Answers to frequently asked questions Live chat with an agent Did you enjoy building your shed?
  • Page 2: Assembly Manual

    16410 06/13/2022 ASSEMBLY MANUAL GAMBREL 10' x 10' (304,8 x 304,8 cm) BUILDING SIZE ACTUAL FLOOR SIZE 10' x 10' (304,8 x 304,8 cm) 10' x 10' (304,8 x 304,8 cm) BASE MODEL 10' x 14' (304,8 x 426,7 cm) ADD (1) 10' x 4' 10' x 14' (304,8 x 426,7 cm) 10' x 18' (304,8 x 548,6 cm)
  • Page 3 TOOLS Required Optional K Phillips K Tool Belt/ K Utility Knife Screwdriver Nail Pouch K Shingle Blades K Drill / Driver K Tin Snips K 3/8" Drill Bit K Caulk Gun (for drip edge) K #2 Philips Drive Bit K Chalk Line K Hammer K Paint Tools K Level...
  • Page 4: Additional Materials

    ADDITIONAL MATERIALS FOUNDATION OR FLOOR MATERIALS • If you purchased a separate floor kit, use instructions and materials in that kit to construct your floor. • See the FLOOR LEVELING section on page 10 for recommended methods and suggested materials to properly level your floor, as this will vary depending on your specific site.
  • Page 5: Optional Materials

    ADDITIONAL MATERIALS COMPLETING YOUR SHED You will need these additional materials: 10x10' 10x14' 10x18' 10x10' 10x14' 10x18' Paint for trim/Quart 3-TAB SHINGLES (Bundles)..Use 100% acrylic latex exterior paint. PAINT FOR SIDING (Gallons)..Caulk Tubes ... Use 100% acrylic latex exterior paint. Use acrylic paintable (2) coats recommended.
  • Page 6 PARTS IDENTIFICATION AND SIZES WOOD SIZE CONVERSION CHART Double letter part identification Nominal Board Size Actual Size is stamped on some parts. 2 x 4 ....1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1 x 4 ....3/4" x 3-1/2" (1,9 x 8,9 cm) •...
  • Page 7 PANEL & DOORS PARTS LIST NOTE: Panel parts are not stamped with part identification. SQUARE SQUARE SQUARE EDGE EDGE EDGE LIP EDGE Left Right 3/8 x 48 x 84" 3/8 x 23-7/8 x 84" (1 x 121,9 x 213,4 cm) (1 x 121,9 x 213,4 cm) 3/8"...
  • Page 8 NAIL BOXES (Shown Actual Size) BOXES 3" (7,6 cm) 2" (5,1 cm) BOXES FASTENER/HARDWARE BAG (Shown Actual Size) 2" (5,1 cm) x200 x110 1-1/2" (3,8 cm) 3" (7,6 cm) 2" (5,1 cm) NOTE: 1-1/4" (3,2 cm) If you are using a nail gun, nails x105 3/4"...
  • Page 9 GAMBREL EXTENDER KIT PARTS LIST Inventory your parts before you begin. We suggest sorting parts by the category they are listed in. WOOD SIZE CONVERSION CHART Part identification is stamped on some parts. Nominal Board Size Actual Size 2 x 4 ....1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1 x 4 ....3/4"...
  • Page 10 CONCRETE FOUNDATION If you choose to install your kit on a concrete slab refer to the diagram below. Attach the sill plates on the foundaton as shown, and continue on to page 14. Treated Sill Plate Caulk between sill plate and concrete.
  • Page 11 OPTIONAL WOOD FRAME FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below. Leveling materials are not included in this kit. PREFERRED METHOD - 4x4 TREATED RUNNERS (Typical for 10' x 10' Kit) Runners are generally 12"...
  • Page 12 LEVELING & SQUARING THE FLOOR FRAME (Not Included) LEVEL AND SQUARE FLOOR FRAME Before attaching fl oor decking, it is important to level and square the fl oor frame. A level and square fl oor frame is required to correctly construct your shed. See page 10 for the preferred f oor leveling method.
  • Page 13 IMPORTANT! I M P O R T A N T ! NOTE: 10' x 10' Gambrel shown standard throughout manual Ensure the foor frame is level after installing foor panels. Re-level if needed. • The foor should used as a stable work surface for wall construction. •...
  • Page 14 (This page intentionally left blank.)
  • Page 15 WALL CONFIGURATION GUIDE Create your own style of shed. Choose your door location. Compare this guide with the wall index to find the corresponding pages. 10' x 10' 10' x 14' 10' x 18' Streamline your wall assembly process by cutting out the pages for the wall configuration guide and the wall index.
  • Page 16 WALL INDEX As another option, eave walls with doors can be reversed during assembly. 10' x 10' After assembling the walls for your 10' x 10' shed, go to page 45 for wall installation. 10' x 10' 10' x 10' V-1 Door is on the 10' gable wall.
  • Page 17: Parts Required

    DOOR HEADER Assemble this door header before building any walls! Any wall with a door will require this assembly. PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 67" (5,1 x 10,2 x 170,2 cm) 7/16 x 3-1/4 x 66-3/4" (1,1 x 8,3 x 170,2 cm) BEGIN Place (1) AM and OSB end-to-end on fl at surface, fl ush in middle.
  • Page 18 WALL PANEL INSTALLATION HINTS & EXAMPLES PARTS REQUIRED: 2" (5,1 cm) 2x3" TEMP. SPACER 3/4" GAUGE BLOCK 3/8 x 48 x 84" (1 x 121,9 x 213,4 cm ) Ensure your wall is square by installing one panel and squaring frame. Install all wall panels with the primed side facing up.
  • Page 19 10' WALL - 01 PARTS REQUIRED: 2 x 4 x 7" (5,1 x 10,2 x 17,8 cm) 3" (7,6 cm) x2 SL 2 x 4 x 36" (5,1 x 10,2 x 91,4 cm) 3" (7,6 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 78-1/2"...
  • Page 20 10' WALL 01 PARTS REQUIRED: 3" (7,6 cm) x150 2" (5,1 cm) 11-7/8" x 84" (30,2 x 213,4 cm) Temporary Brace 69" (75,3 cm) Door Stiffener Install the left panel 1-1/2" 1-1/2" Flush from the top plate. (3,8 cm) 3/4" BEGIN HERE Use a 2x3 spacer for (1,9 cm)
  • Page 21 10' WALL 02 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 24" (5,1 x 10,2 x 61 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) BEGIN Orient parts on edge on floor as shown.
  • Page 22 10' WALL 02 PARTS REQUIRED: x136 2" (5,1 cm) 48 x 84" 23-7/8" x 84" (121,9 x 213,4 cm ) (60,6 x 213,4 cm ) 1-1/2" (3,8 cm) 3/4" BEGIN HERE (1,9 cm) Install 48" x 84" panel 1-1/2" from the top plate. Use a 2x3 spacer for consistent measurement.
  • Page 23 10' WALL 03 PARTS REQUIRED: 3" (7,6 cm) x2 SL 2 x 4 x 36" (5,1 x 10,2 x 91,4 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 84" (5,1 x 10,2 x 213,4 cm) BEGIN Orient parts on edge on floor as shown.
  • Page 24 10' WALL 03 PARTS REQUIRED: x164 2" (5,1 cm) (x1 Left & x1 Right) 48 x 84" (121,9 x 213,4 cm ) 11-7/8" x 84" (30,2 x 213,4 cm) 3/4" BEGIN HERE Install 48" x 84" panel (1,9 cm) 1-1/2" (3,8 cm) 1-1/2"...
  • Page 25 10' WALL 04 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 68-1/2" (5,1 x 10,2 x 174 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) Build two identical walls if your 10'x10' shed has the door on the gable side.
  • Page 26 10' WALL 04 PARTS REQUIRED: x106 2" (5,1 cm) 48 x 84" 23-7/8" x 84" (121,9 x 213,4 cm ) (60,6 x 213,4 cm ) 3/4" BEGIN HERE (1,9 cm) 3-1/2" Install 48" x 84" panel (8,9 cm) 1-1/2" from the top plate. 1-1/2"...
  • Page 27 10' WALL 05 PARTS REQUIRED: 2 x 4 x 7" (5,1 x 10,2 x 17,8 cm) 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 3" (7,6 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 28 10' WALL 05 PARTS REQUIRED: 3" (7,6 cm) x115 2" (5,1 cm) 23-7/8" x 84" Temporary Brace (60,6 x 213,4 cm ) 69" (75,3 cm) Door Stiffener 3-1/2" (8,9 cm) 1-1/2" Flush Install the left panel 1-1/2" (3,8 cm) 3/4" BEGIN HERE from the top plate.
  • Page 29 14' WALL 06 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 78-1/2" (5,1 x 10,2 x 199,4 cm) 2 x 4 x 68-1/2"...
  • Page 30 14' WALL 06 PARTS REQUIRED: x156 2" (5,1 cm) 23-7/8" x 84" (60,6 x 213,4 cm ) 48 x 84" (121,9 x 213,4 cm ) Install (1) 48" x 84" panel 1-1/2" from 3/4" BEGIN HERE (1,9 cm) the top plate. 1-1/2"...
  • Page 31 14' WALL 07 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 3" (7,6 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 32 14' WALL 07 PARTS REQUIRED: 3" (7,6 cm) x150 2" (5,1 cm) 23-7/8" x 84" (60,6 x 213,4 cm ) Temporary Brace 69" (75,3 cm) Door Stiffener 48 x 84" (121,9 x 213,4 cm ) 1-1/2" Flush (3,8 cm) Install the left panel 1-1/2" 3/4"...
  • Page 33 14' WALL 08 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 34 14' WALL 08 PARTS REQUIRED: 3" (7,6 cm) x150 23-7/8" x 84" 2" (5,1 cm) (60,6 x 213,4 cm ) Temporary Brace 48 x 84" (121,9 x 213,4 cm ) 69" (75,3 cm) Door Stiffener 1-1/2" Flush Install the left panel 1-1/2" (3,8 cm) 3/4"...
  • Page 35 14' WALL 09 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 3" (7,6 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 36 14' WALL 09 PARTS REQUIRED: 3" (7,6 cm) x150 23-7/8" x 84" 2" (5,1 cm) (60,6 x 213,4 cm ) Temporary Brace 48 x 84" (121,9 x 213,4 cm ) 69" (75,3 cm) Door Stiffener 3-1/2" 1-1/2" Install the left panel Flush (8,9 cm) (3,8 cm)
  • Page 37 18' WALL 10 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 68-1/2" (5,1 x 10,2 x 174 cm) 2 x 4 x 78-1/2"...
  • Page 38 18' WALL 10 PARTS REQUIRED: x206 2" (5,1 cm) 23-7/8" x 84" (60,6 x 213,4 cm ) 48 x 84" (121,9 x 213,4 cm ) Install (1) 48" x 84" panel 1-1/2" from 3/4" BEGIN HERE (1,9 cm) the top plate. 1-1/2"...
  • Page 39 18' WALL 11 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 3" (7,6 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 40 18' WALL 11 PARTS REQUIRED: 3" (7,6 cm) x200 2" (5,1 cm) 23-7/8" x 84" (60,6 x 213,4 cm ) Temporary Brace 69" (75,3 cm) Door Stiffener 48 x 84" (121,9 x 213,4 cm ) Install the left panel 1-1/2" from the top plate. Use a 2x3 spacer for consistent measurement. Secure panel with 2"...
  • Page 41 18' WALL 12 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 42 18' WALL 12 PARTS REQUIRED: 3" (7,6 cm) x200 2" (5,1 cm) 23-7/8" x 84" (60,6 x 213,4 cm ) Temporary Brace 69" (75,3 cm) Door Stiffener 48 x 84" (121,9 x 213,4 cm ) Install the left panel 1-1/2" from the top plate. Use a 2x3 spacer for consistent measurement. Secure panel with 2"...
  • Page 43 18' WALL 13 PARTS REQUIRED: 3" (7,6 cm) 2 x 4 x 44-1/2" (5,1 x 10,2 x 113 cm) 3" (7,6 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 2 x 4 x 68" (5,1 x 10,2 x 172,7 cm) 2 x 4 x 68-1/2"...
  • Page 44 18' WALL 13 PARTS REQUIRED: 3" (7,6 cm) x200 23-7/8" x 84" 2" (5,1 cm) (60,6 x 213,4 cm ) Temporary Brace 48 x 84" (121,9 x 213,4 cm ) 69" (75,3 cm) Door Stiffener Install the left panel 1-1/2" from the top plate. Use a 2x3 spacer for consistent measurement. Secure panel with 2"...
  • Page 45 STANDING YOUR WALLS The following steps show how to stand and secure your walls for a 10' x 10' shed. These instructions are by default with the door on the 10' gable wall. STANDARD: DOOR LOCATED ON 10' GABLE WALL OPTIONAL: DOOR LOCATED ON 10' EAVE WALL...
  • Page 46 10' GABLE WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 69" (175,3 cm) Door Stiffener 3" (7,6 cm) 2" (5,1 cm) BEGIN 1-1/2" (3,8 cm) Center 10' wall on the 120" (304,8 cm) fl oor dimension. 1-1/2" (3,8 cm) overlap is to the top. Use OO as a temporary brace.
  • Page 47 10' EAVE WALL INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 1-1/2" (3,8 cm) 3" (7,6 cm) Fig. B BEGIN Place 10' eave wall centered on fl oor. 1-1/2" (3,8 cm) overlap is to the top. 2"...
  • Page 48 10' EAVE WALL INSTALLATION PARTS REQUIRED: 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) 1-1/2" (3,8 cm) Fig. B BEGIN 1-1/2" (3,8 cm) Remove temporary brace OO from installed 10' gable wall. Place 2nd 10' eave wall centered on fl oor 2"...
  • Page 49 10' GABLE WALL INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 1-1/2" (3,8 cm) 3" (7,6 cm) Fig. B BEGIN 2" (5,1 cm) Place 10'gab;le wall on fl oor centered between Screw installed' walls. Secure wall with 2" screws into top and bottom plates (Fig.
  • Page 50 10' x 10' WALL DOUBLERS INSTALLATION PARTS REQUIRED: 3" (7,6 cm) x2 RL x2 JBD 2 x 4 x 24" (5,1 x 10,2 x 61 cm) 2 x 4 x 20-3/8" (5,1 x 10,2 x 51,8 cm) 3" (7,6 cm) 2 x 4 x 92-5/8"...
  • Page 51 14' GABLE WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 69" (175,3 cm) Door Stiffener 3" (7,6 cm) 2" (5,1 cm) BEGIN 1-1/2" (3,8 cm) Center 10' wall on the 120" (304,8 cm) fl oor dimension. 1-1/2" (3,8 cm) overlap is to the top. 3"...
  • Page 52 14' EAVE WALL INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) Temporary Brace 1-1/2" (3,8 cm) 2 x 4 x 92-5/8" (5,1 x 10,2 x 235 cm) 2" (5,1 cm) 3" (7,6 cm) Fig. B BEGIN Place 1st 14' eave wall centered on fl oor. 2"...
  • Page 53 14' EAVE WALL INSTALLATION PARTS REQUIRED: 2" (5,1 cm) 3" (7,6 cm) Temporary Brace 2 x 4 x 92-5/8" (5,1 x 10,2 x 235 cm) 1-1/2" BEGIN (3,8 cm) Remove temporary brace OO from installed 10' wall. Place 2nd 14' wall centered on fl oor. 3"...
  • Page 54 14' EAVE WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) 1-1/2" (3,8 cm) Nail lower edge of wall panels to fl oor frame with 2" nails spaced 6" apart. Angle nails into fl oor frame (Fig. C). Secure wall bottom plates to fl oor 3"...
  • Page 55 10' GABLE WALL INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) 1-1/2" (3,8 cm) Fig. B BEGIN 2" (5,1 cm) Place 10' gable wall on fl oor centered Screw between installed walls. Secure wall with 2" screws into top and bottom plates (Fig.
  • Page 56 10' x 14' WALL DOUBLERS INSTALLATION PARTS REQUIRED: 3" (7,6 cm) x2 JBD 2 x 4 x 20-3/8" (5,1 x 10,2 x 51,8 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 3" (7,6 cm) 2 x 4 x 92-5/8" (5,1 x 10,2 x 235 cm) x2 RL 2 x 4 x 96"...
  • Page 57 10' GABLE WALL INSTALLATION PARTS REQUIRED: 3" (7,6 cm) 69" (175,3 cm) Door Stiffener 3" (7,6 cm) 2" (5,1 cm) 1-1/2" BEGIN (3,8 cm) Center 10' wall on the 120" (304,8 cm) fl oor dimension. 1-1/2" (3,8 cm) overlap is to the top. 3"...
  • Page 58 18' EAVE WALL INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) Temporary Brace 1-1/2" (3,8 cm) 2 x 4 x 92-5/8" (5,1 x 10,2 x 235 cm) 2" (5,1 cm) 3" (7,6 cm) Fig. B BEGIN Place 1st 18' eave wall centered on fl oor. 2"...
  • Page 59 18' EAVE WALL INSTALLATION PARTS REQUIRED: 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) Temporary Brace 1-1/2" (3,8 cm) 2 x 4 x 92-5/8" (5,1 x 10,2 x 235 cm) 2" (5,1 cm) 1-1/2" BEGIN Fig. B (3,8 cm) Screw Remove temporary brace OO from installed 10' wall.
  • Page 60 10' GABLE WALL INSTALLATION PARTS REQUIRED 2" (5,1 cm) 3" (7,6 cm) 2" (5,1 cm) 3" (7,6 cm) 1-1/2" (3,8 cm) Fig. B BEGIN 2" (5,1 cm) Place 10' gable wall on fl oor centered Screw between installed walls. Secure wall with 2" screws into top and bottom plates (Fig.
  • Page 61 10' x 18' WALL DOUBLERS INSTALLATION PARTS REQUIRED: x2 JBD 3" (7,6 cm) 2 x 4 x 20-3/8" (5,1 x 10,2 x 51,8 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) 3" (7,6 cm) 2 x 4 x 92-5/8" (5,1 x 10,2 x 235 cm) x2 RL 2 x 4 x 24"...
  • Page 62 RAFTERS 10x10' 10x14' 10x18' PARTS REQUIRED: 3" (7,6 cm) 6 x 24" (15,2 x 60,9 cm) x1 RL Temporary Support 2 x 4 x 24" (5,1 x 10,2 x 61 cm) Pre-assembled x216 x120 x168 2" (5,1 cm) Build (2) rafter assemblies with(1) gusset (Fig. B). BEGIN HINT: Use fl oor and walls to help...
  • Page 63 10x18' 10x10' 10x14' RAFTER INSTALLATION PARTS REQUIRED: Page 63 Two-Gusset Preassembled One-Gusset Preassembled 3" (7,6 cm) BEGIN Align rafters over the wall studs. Check that you have the measurements shown. Secure rafters with (2) 3" screws angled at each end (Fig. A, Fig. B). Secure rafters on opposite side.
  • Page 64 10x18' RAFTER INSTALLATION PARTS REQUIRED: Two-Gusset Preassembled One-Gusset Preassembled 3" (7,6 cm) BEGIN Align rafters over the wall studs. Check that you have the measurements shown. Secure rafters with (2) 3" screws angled at each end (Fig. A, Fig. B). Secure rafters on opposite side.
  • Page 65 GABLE HAY LOFT TRIM PARTS REQUIRED: 2" (5,1 cm) 3/4" (1,9 cm) 19/32" x 2-1/2" x 12-7/8" (1,6 x 7,6 x 32,7 cm) 19/32" x 2-1/2" X 21-3/4" (1,6 x 7,6 x 55,2 cm) x1 LKA x2 QL Temporary Support 2 x 4 x 39"...
  • Page 66 GABLE PANELS PARTS REQUIRED: 1-1/2" (3,8cm) x4 QL 2 x 4 x 39" (5,1 x 10,2 x 99,1 cm) Install gable panels with the primed side facing up. BEGIN BEGIN Orient parts QL on the fl at side, as shown. Measure and mark the center of the middle gable panel.
  • Page 67 GABLE INSTALLATION PARTS REQUIRED: 3" (7,6 cm) x114 2" (5,1 cm) Pre - assembled BEGIN Measure 2-9/16" down from top plate doubler and mark at each side as shown. Set gable unit on top plate. Fasten with (1) 2" nail on each side. BE SURE GABLE IS CENTERED ON WALL BEFORE NAILING.
  • Page 68 10' x 10' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE BLOCK 7/16 x 48 x 96" (1,1 x 121,9 x 243,8 cm) Roof panels may cause serious injury until securely fastened. Note: Install all roof panels with the rough side up (painted grid lines). BEGIN Flush at Place the 48"...
  • Page 69 10' x 10' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 7/16 x 23-7/8 x 48" (1,1 x 60,6 x 121,9 cm) Flush at Install a 23-7/8" x 48" roof panel flush to the peak installed panel and flush at peak (Fig. B). Fig.
  • Page 70 10' x 10' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 23-7/8" x 96" 23-7/8" x 24" (60,6 x 243,8 cm) (60,6 x 61 cm) 3/4" GAUGE BLOCK 11-7/8" x 24" 11-7/8" x 96" (30,2 cm x 243,8 cm) (30,2 x 61 cm) Next, install 23-7/8"...
  • Page 71 10' x 10' ROOF PANELS PARTS REQUIRED: x166 2" (5,1 cm) Secure all roof panels with 2" nails spaced 6" apart and 12" apart inside of the upper panels. 6" (15,2 cm) Repeat all steps to install roof panels on the opposite side. FINISH Your roof panels are now installed.
  • Page 72 10' x 14' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE BLOCK 48 x 96" (121,9 x 243,8 cm) Roof panels may cause serious injury until securely fastened. Note: Install all roof panels with the rough side up (painted grid lines). BEGIN Flush at peak...
  • Page 73 10' x 14' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 47-7/8 x 48" 23-7/8 x 48" (121,6 x 121,9 cm) (121,6 x 121,9 cm) Flush at 1/2" peak Install 47-7/8" x 48" roof panel (1,2 cm) Fig. B flush to the installed panel and flush at the peak (Fig.
  • Page 74 10' x 14' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 23-7/8" x 48" 23-7/8" x 96" 23-7/8" x 24" (60,6 x 121,9 cm) (60,6 x 243,8 cm) (60,6 x 61 cm) 3/4" GAUGE BLOCK 11-7/8" x 24" 11-7/8" x 48" 11-7/8"...
  • Page 75 10' x 14 ROOF PANELS PARTS REQUIRED: x240 2" (5,1 cm) Secure all roof panels with 2" nails spaced 6" apart and 12" apart inside panels. 6" (15,2 cm) Repeat all steps to install roof panels on the opposite side. FINISH Your roof panels are now installed.
  • Page 76 10' x 18' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 48 x 96" 3/4" GAUGE BLOCK (121,9 x 243,8 cm) Roof panels may cause serious injury until securely fastened. Note: Install all roof panels with the rough side up (painted grid lines). BEGIN Flush at peak...
  • Page 77 10' x 14' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 3/4" GAUGE 47-7/8 x 48" 23-7/8 x 48" BLOCK (121,6 x 121,9 cm) (121,6 x 121,9 cm) 1/2" Flush at (1,2 cm) Fig. C peak Install 23-7/8" x 48" roof panel Fig.
  • Page 78 10' x 14' ROOF PANELS PARTS REQUIRED: 2" (5,1 cm) 23-7/8" x 48" 23-7/8" x 96" 23-7/8" x 24" (60,6 x 243,8 cm) (60,6 x 61 cm) (60,6 x 121,9 cm) 3/4" GAUGE BLOCK 11-7/8" x 24" 11-7/8" x 48" 11-7/8"...
  • Page 79 10' x 14' ROOF PANELS PARTS REQUIRED: x314 2" (5,1 cm) Secure all roof panels with 2" nails spaced 6" apart and 12" apart inside panels. 6" (15,2 cm) Repeat all steps to install roof panels on the opposite side. We suggest installing the 2nd set of panels in the confi guration shown (Fig.
  • Page 80 GABLE TRIM PARTS REQUIRED: 2" (5,1 cm) 5/8 x 4 x 48-5/16 5/8 x 4 x 36" (1,6 x 10 x 123 cm) (1,6 x 10 x 91 cm) 5/8 x 4 x 48-5/16 5/8 x 4 x 36" (1,6 x 10 x 123 cm) (1,6 x 10 x 91 cm) BEGIN Install upper gable trim ZQR and ZQL fl ush to top of roof panels and fl ush at peak.
  • Page 81 CORNER TRIM PARTS REQUIRED: 2" (5,1 cm) 3/8" x 1-3/4" x 83-1/4" (1 x 4,5 x 211,5 cm) BEGIN Install gable end 83-1/4" corner trim under gable panel, (Fig. A) and fl ush to eave wall panel (Fig. B). Secure with 2" fi nishing nails spaced evenly. Install eave side 83-1/4"...
  • Page 82 10x10' 10x14' 10x18' COLLAR TIE INSTALLATION PARTS REQUIRED: 2 x 4 x 96" (5,1 x 10,2 x 243,9 cm) 3" (7,6 cm) BEGIN Install collar tie to the rafter with (3) 3" nails at each end Fig. A (Fig. A). Flush to roof Starting at the wall with the door, install fi rst panel.
  • Page 83 DOORS PARTS REQUIRED: 3" (7,6 cm) 1-1/4" (3,2 cm) 1 x 3 x 5" (2,5 x 7,6 x 12,7 cm) 69" (175,3 cm) Door Stiffener Left Door Right Door BEGIN Place doors on flat surface. 3/8" offset is to top. Look for red (right) and green (left) on hinge board.
  • Page 84 DOORS PARTS REQUIRED: 3" (7,6 cm) TEMPORARY SUPPORT 69" (175,3 cm) Door Stiffener Install OO fl ush under panels. Secure to fl oor frame with (2) 3" screws (Fig. A) . Mark center of door opening. Fig. A Flush against wall panels (2) 3"...
  • Page 85 DOORS PARTS REQUIRED: 2" (5,1 cm) 3/4" (1,9 cm) 19/32" x 2-1/2" x 26 5/8" (1,5 x 6,3 x 67,6 cm) 19/32" x 2-1/2" x 72" (1,5 x 7,6 x 182,9 cm) 19/32" x 2-1/2" x 39-7/8" (1,5 x 6,3 x 101,3 cm) 19/32"...
  • Page 86 DOOR STIFFENERS PARTS REQUIRED: 2" (5,1 cm) 69" (175,3 cm) Door Stiffener BEGIN Center OO vertically on the left door in the doorway (Fig. A) overlapping 1" (2,5 cm) along the edge of door (Fig. B). Secure with (7) 2" screws through outside trim into OO. Center OO vertically on the right door in the door opening offset 1"...
  • Page 87: Door Hardware

    DOOR HARDWARE PARTS REQUIRED: 5/16" (7,9 mm) Drill Bit 3/4" (1,9 cm) BEGIN Place bolt on OO in open position with bolt end 3/8" (9,5 mm) down from frame. Bolt is open when loop is contacting base (Fig A). Mark and pre-drill holes for screws. Install bolt with screws supplied. Drill 5/16"...
  • Page 88: Right Door

    DOOR HARDWARE PARTS REQUIRED: 1" (2,5 cm) 1-1/4" (3,2 cm) 1/2" (13 mm) Drill Bit 1/4" (6 mm) Drill Bit BEGIN Measure and mark location of hole on outside of right door as shown (Fig. A) . Pre-drill hole with 1/4" drill. Re-drill hole with 1/2"...
  • Page 89 HOOK & EYE PARTS REQUIRED: ¸ BEGIN Install hooks in wall and into framing behind (Fig.A). Fig. A Swing door open to locate eye. Hook Install hook into framing, if possible. FINISH You have installed your hook & eyes.
  • Page 90 VENT (Not included in kit.) • Follow directions provided by manufacturer and these instructions. 1/2" (13 mm) 16" x 8" BEGIN Locate and mark for two vents in side walls as shown; (1) at top and (1) at bottom. Cut out marked openings. Caulk behind vent fl anges.
  • Page 91 PAINT & CAULK - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: •...
  • Page 92 SHINGLES - NOT INCLUDED - • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. Notch Notch SHINGLE NAIL PATTERN 1/2" 1" Sealing Strip (1,3 cm) 1" (2,5 cm) (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS.
  • Page 93 SHINGLES continued... Beginning at front of shed, install first row of shingles with notch at 1" past roof edge or flush with drip edge. Roof Deck FRONT OF BACK OF SHED SHED 1" (2,5 cm) Flush with starter row. Notch - or - Drip Edge Flush with starter row.
  • Page 94 SHINGLES continued... Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife. 5"...
  • Page 95 SHINGLES - RIDGE CAP • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN Cut shingles in THREE pieces. Hint: Use cut-off pieces first. 2" 2" (5,1 cm) (5,1 cm) 2" 2" 2"...
  • Page 96 SHINGLES - RIDGE CAP continued... Continue installing ridge cap to back of roof. Make sure there is 4" between the shingle-color and edge of shingles. 4" (10,2 cm) Trim cap off f ush to shingles When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot.
  • Page 97 16410 10' x10' Order Form CATEGORY PART DESCRIPTION PART SIZE PART ITEM # BUILDING QTY. PART ID Back Wall Top & Btm "A" / Dblr "A" / Collar Tie LUM SPF 2X4X96 #2&BTR 12306 Doubler "B" LUM SPF 2X4X92-5/8 #2&BTR 12305 Side Wall Plate "B"...
  • Page 98: Claim Procedure

    LIMITED CONDITIONAL WARRANTY* Backyard Storage Solutions, LLC warrants the following: Every product is warranted from defects in workmanship and manufacturing for 1 year. All accessories, hardware and metal components are warranted for 2 years. All Oriented Strand Board (OSB) is warranted for 2 years Siding and Trim is warranted for 15 years.

Table of Contents