Page 1
2R67, 4R39, 4R40, 4R85, 4R86 Instructions for use (qualified personnel) ................
Page 2
Documentu 647G23 Versionu 23 SCAN ME httpsu//product-documents.ottobock.com/IFU/INT/2R67/647G23/23/O/S/F DE | Weisen Sie den Benutzer in den sicheren Gebrauch des Produkts ein. Weitere Sprachen dieser Gebrauchsanweisung sind online verfügbar oder können kostenlos als gedrucktes Exemplar bestellt werden (siehe Seite 2). EN | Instruct the user how to use the product safely.
Page 3
TR | Ürünün güvenle kullanımı konusunda kullanıcıyı bilgilendirin. Bu kullanım kılavuzundaki diğer diller online olarak mevcuttur veya ücretsiz basılı kopya olarak sipariş verilebilir (bkz. sayfa 2). JA | 使用者には、本製品のは全な取り扱い方法を説明してください。 本取扱説明書のその他言語は、オンラインで入手可能ですが、印刷版も無料で注文できます (P2を参照)。 Basic UDI-DI: 2R67*: 406441100000000002R67JM 4R39: 406441100000000004R39JW 4R85: 406441100000000004R85K5 4R86: 406441100000000004R86K7...
Please keep this document for your records. ► In the following, the "4R39, 4R40, 4R85, 4R86 torsion adapter" / "2R67 tube adapter with torsion unit" is called the product/adapter/torsion adapter/tube adapter. These instructions for use provide you with important information on the use, adaptation and handling of the product.
(unrestricted outdoor walker with particularly high demands). Approved for a body weight of 110 kg max. 2R67, 4R39, 4R40 The product is recommended for mobility grade 1 (indoor walker), mobility grade 2 (restricted outdoor walker), mobility grade 3 (unrestricted outdoor walker) and m°...
Page 7
4.2 Structure of the safety instructions CAUTION The heading describes the source and/or the type of hazard The introduction describes the consequences in case of failure to observe the safety instruc tions. Consequences are presented as follows if more than one consequence is possible: >...
5 Scope of delivery • 1 pc. Instructions for use (qualified personnel) • 1 pc. 4R39/4R40/4R85/4R86 torsion adapter / 2R67 tube adapter with torsion unit 6 Preparing the product for use CAUTION Incorrect alignment or assembly Falling due to damage to the prosthesis components.
Page 9
6.3 Mounting the adapter 6.3.1 Mounting the torsion adapter (4R39) or tube adapter with torsion unit (2R67) ► Fully insert the 2R67, 4R39 tube adapter into the tube clamp adapter up to the stop. 6.3.2 Mounting the torsion adapter (4R40) 1) Remove the screws on the socket attachment block or modular adapter.
The torsion moment can be adjusted with the Allen head screw in the centre of the adapter (see fig. 1). Increasing the torsion moment: ► Turn the mark in the centre of the torsion unit clockwise. Decreasing the torsion moment: ► Turn the mark in the centre of the torsion unit counterclockwise. 7 Handling 7.1 Adjusting adapter The set screws in the pyramid receiver can be used to make static adjustments during alignment...
10.3 CE conformity Otto Bock Healthcare Products GmbH hereby declares that the product is in compliance with European requirements for medical devices. The full text of the regulations and requirements is available at the following Internet address: http://www.ottobock.com/conformity...
Need help?
Do you have a question about the 2R67 and is the answer not in the manual?
Questions and answers