Available Easy Config Modes
5.5. Available Easy Config Modes
Bridge II CAN may be configured using one of the pre-configured Easy Config modes.
NOTE
By default, the unit starts in Easy Config Mode 4. The unit awaits
automatic configuration during 120 seconds or until receiving a
configuration.
NOTE
To cancel Easy Config mode 11, the unit must be reset to factory default
settings. See
Table 3. Easy Config modes
EC
Active LED
Role
1
A
Bluetooth
PANU
2
B
N/A
3
A B
N/A
4
C
Client
5
A
C
WLAN AP
6
B C
Bluetooth
NAP
11
A B
D
(any)
SP2965 1.4
Reset to Factory Default (page 20)
Description
Used for setting up point-to-point communication.
The unit scans for another unit in Config Mode 4. The unit listens for 40 seconds
or until a configuration is established.
When a unit in mode 4 is detected: The scanning unit configures itself as a
Bluetooth PANU Client, sends a connection configuration to the detected unit,
and restarts. The detected unit restarts and attempt to connect to the first unit
as a PANU Client.
Reset configuration to factory defaults.
Reset IP settings to factory defaults.
Configure units in mode 4 as Clients.
Wait for automatic configuration. The unit listens for 120 seconds or until
receiving a configuration.
When mode 4 is used with mode 1, 5 or 6, CAN Settings TCP Mode Client is
activated automatically.
The unit scans for other units in Config Mode 4 and configure them as Clients.
Timeout occur after 120 seconds.
Restart as Access Point and connect Clients.
Enable PROFIsafe mode. The unit is locked in PROFIsafe mode.
No other configuration settings are changed.
®